A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 "return-to-flow" method

Frank E Block, Mark V. Fletcher, Timothy J. Morris, Roger Dzwonczyk

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Most commercial noninvasive blood pressure devices use the oscillometric method for determination of blood pressure. The Ohmeda 2120 noninvasive blood pressure monitor uses the oscillometric technique, but it also includes a "Sys Stat" mode for rapid determination of systolic blood pressure up to ten times per minute. This Sys Stat mode uses the "return-to-flow" method, in which the pressure on an upper arm cuff decreases in small steps until a finger sensor detects the first pulse of blood. Data from 16 patients monitored with the Ohmeda 2120 unit and with an arterial cannula were analyzed. The line of regression was Sys Stat = 0.85 (arterial) + 9.49. The Ohmeda 2120 monitor tended to under-estimate the arterial pressure, particularly at higher pressures. Several factors could have contributed to this underestimation. Even so, the accuracy is sufficient for clinical use under most circumstances. More importantly, in an urgent situation, the Sys Stat mode can provide a reading of systolic blood pressure within seconds.

Original languageEnglish (US)
Pages (from-to)241-244
Number of pages4
JournalJournal of Clinical Monitoring
Volume7
Issue number3
DOIs
StatePublished - Jul 1 1991

Fingerprint

Blood Pressure Determination
Blood Pressure
Blood Pressure Monitors
Pressure
Fingers
Pulse
Reading
Arterial Pressure
Arm
Equipment and Supplies

Keywords

  • Blood pressure: measurement monitoring
  • Measurement techniques: blood pressure
  • Monitoring: blood pressure

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine

Cite this

A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 "return-to-flow" method. / Block, Frank E; Fletcher, Mark V.; Morris, Timothy J.; Dzwonczyk, Roger.

In: Journal of Clinical Monitoring, Vol. 7, No. 3, 01.07.1991, p. 241-244.

Research output: Contribution to journalArticle

Block, Frank E ; Fletcher, Mark V. ; Morris, Timothy J. ; Dzwonczyk, Roger. / A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 "return-to-flow" method. In: Journal of Clinical Monitoring. 1991 ; Vol. 7, No. 3. pp. 241-244.
@article{226d7c9f5205488cb087399dc37f95a0,
title = "A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 {"}return-to-flow{"} method",
abstract = "Most commercial noninvasive blood pressure devices use the oscillometric method for determination of blood pressure. The Ohmeda 2120 noninvasive blood pressure monitor uses the oscillometric technique, but it also includes a {"}Sys Stat{"} mode for rapid determination of systolic blood pressure up to ten times per minute. This Sys Stat mode uses the {"}return-to-flow{"} method, in which the pressure on an upper arm cuff decreases in small steps until a finger sensor detects the first pulse of blood. Data from 16 patients monitored with the Ohmeda 2120 unit and with an arterial cannula were analyzed. The line of regression was Sys Stat = 0.85 (arterial) + 9.49. The Ohmeda 2120 monitor tended to under-estimate the arterial pressure, particularly at higher pressures. Several factors could have contributed to this underestimation. Even so, the accuracy is sufficient for clinical use under most circumstances. More importantly, in an urgent situation, the Sys Stat mode can provide a reading of systolic blood pressure within seconds.",
keywords = "Blood pressure: measurement monitoring, Measurement techniques: blood pressure, Monitoring: blood pressure",
author = "Block, {Frank E} and Fletcher, {Mark V.} and Morris, {Timothy J.} and Roger Dzwonczyk",
year = "1991",
month = "7",
day = "1",
doi = "10.1007/BF01619267",
language = "English (US)",
volume = "7",
pages = "241--244",
journal = "Journal of Clinical Monitoring and Computing",
issn = "1387-1307",
publisher = "Springer Netherlands",
number = "3",

}

TY - JOUR

T1 - A clinical evaluation of rapid automatic noninvasive blood pressure determination with the Ohmeda 2120 "return-to-flow" method

AU - Block, Frank E

AU - Fletcher, Mark V.

AU - Morris, Timothy J.

AU - Dzwonczyk, Roger

PY - 1991/7/1

Y1 - 1991/7/1

N2 - Most commercial noninvasive blood pressure devices use the oscillometric method for determination of blood pressure. The Ohmeda 2120 noninvasive blood pressure monitor uses the oscillometric technique, but it also includes a "Sys Stat" mode for rapid determination of systolic blood pressure up to ten times per minute. This Sys Stat mode uses the "return-to-flow" method, in which the pressure on an upper arm cuff decreases in small steps until a finger sensor detects the first pulse of blood. Data from 16 patients monitored with the Ohmeda 2120 unit and with an arterial cannula were analyzed. The line of regression was Sys Stat = 0.85 (arterial) + 9.49. The Ohmeda 2120 monitor tended to under-estimate the arterial pressure, particularly at higher pressures. Several factors could have contributed to this underestimation. Even so, the accuracy is sufficient for clinical use under most circumstances. More importantly, in an urgent situation, the Sys Stat mode can provide a reading of systolic blood pressure within seconds.

AB - Most commercial noninvasive blood pressure devices use the oscillometric method for determination of blood pressure. The Ohmeda 2120 noninvasive blood pressure monitor uses the oscillometric technique, but it also includes a "Sys Stat" mode for rapid determination of systolic blood pressure up to ten times per minute. This Sys Stat mode uses the "return-to-flow" method, in which the pressure on an upper arm cuff decreases in small steps until a finger sensor detects the first pulse of blood. Data from 16 patients monitored with the Ohmeda 2120 unit and with an arterial cannula were analyzed. The line of regression was Sys Stat = 0.85 (arterial) + 9.49. The Ohmeda 2120 monitor tended to under-estimate the arterial pressure, particularly at higher pressures. Several factors could have contributed to this underestimation. Even so, the accuracy is sufficient for clinical use under most circumstances. More importantly, in an urgent situation, the Sys Stat mode can provide a reading of systolic blood pressure within seconds.

KW - Blood pressure: measurement monitoring

KW - Measurement techniques: blood pressure

KW - Monitoring: blood pressure

UR - http://www.scopus.com/inward/record.url?scp=0025868448&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025868448&partnerID=8YFLogxK

U2 - 10.1007/BF01619267

DO - 10.1007/BF01619267

M3 - Article

VL - 7

SP - 241

EP - 244

JO - Journal of Clinical Monitoring and Computing

JF - Journal of Clinical Monitoring and Computing

SN - 1387-1307

IS - 3

ER -