Use of a resorbable barrier (TC-7) to reduce adhesion formation was examined in the rabbit uterine horn model. Early evaluation (four days) established that the material remained where initially placed. Examination at two, four and eight weeks postoperatively in both control and treated groups revealed that the extent of adhesion formation did not change as a function of time. When compared to control animals without TC-7, the treated rabbits had a significant reduction (P<.01) in postoperative adhesion formation. No complications from use of this fabric were noted, and no gross remnants were noted at the two-week time point. TC-7 appears to be an efficacious barrier for reducing adhesion formation in the rabbit uterine horn model.

Original languageEnglish (US)
Pages (from-to)17-20
Number of pages4
JournalJournal of Reproductive Medicine for the Obstetrician and Gynecologist
Volume32
Issue number1
StatePublished - Apr 1 1987
Externally publishedYes

Fingerprint

Rabbits
Control Groups

ASJC Scopus subject areas

  • Obstetrics and Gynecology
  • Reproductive Medicine

Cite this

Adhesion reduction in the rabbit uterine horn model using an absorbable barrier, TC-7. / Linsky, C. B.; Diamond, Michael Peter; Cunningham, T.; Constantine, B.; DeCherney, A. H.; diZerega, G. S.

In: Journal of Reproductive Medicine for the Obstetrician and Gynecologist, Vol. 32, No. 1, 01.04.1987, p. 17-20.

Research output: Contribution to journalArticle

Linsky, C. B. ; Diamond, Michael Peter ; Cunningham, T. ; Constantine, B. ; DeCherney, A. H. ; diZerega, G. S. / Adhesion reduction in the rabbit uterine horn model using an absorbable barrier, TC-7. In: Journal of Reproductive Medicine for the Obstetrician and Gynecologist. 1987 ; Vol. 32, No. 1. pp. 17-20.
@article{b40f773d9e884d178d0bab916019974a,
title = "Adhesion reduction in the rabbit uterine horn model using an absorbable barrier, TC-7",
abstract = "Use of a resorbable barrier (TC-7) to reduce adhesion formation was examined in the rabbit uterine horn model. Early evaluation (four days) established that the material remained where initially placed. Examination at two, four and eight weeks postoperatively in both control and treated groups revealed that the extent of adhesion formation did not change as a function of time. When compared to control animals without TC-7, the treated rabbits had a significant reduction (P<.01) in postoperative adhesion formation. No complications from use of this fabric were noted, and no gross remnants were noted at the two-week time point. TC-7 appears to be an efficacious barrier for reducing adhesion formation in the rabbit uterine horn model.",
author = "Linsky, {C. B.} and Diamond, {Michael Peter} and T. Cunningham and B. Constantine and DeCherney, {A. H.} and diZerega, {G. S.}",
year = "1987",
month = "4",
day = "1",
language = "English (US)",
volume = "32",
pages = "17--20",
journal = "Journal of Reproductive Medicine",
issn = "0024-7758",
publisher = "Donna Kessel",
number = "1",

}

TY - JOUR

T1 - Adhesion reduction in the rabbit uterine horn model using an absorbable barrier, TC-7

AU - Linsky, C. B.

AU - Diamond, Michael Peter

AU - Cunningham, T.

AU - Constantine, B.

AU - DeCherney, A. H.

AU - diZerega, G. S.

PY - 1987/4/1

Y1 - 1987/4/1

N2 - Use of a resorbable barrier (TC-7) to reduce adhesion formation was examined in the rabbit uterine horn model. Early evaluation (four days) established that the material remained where initially placed. Examination at two, four and eight weeks postoperatively in both control and treated groups revealed that the extent of adhesion formation did not change as a function of time. When compared to control animals without TC-7, the treated rabbits had a significant reduction (P<.01) in postoperative adhesion formation. No complications from use of this fabric were noted, and no gross remnants were noted at the two-week time point. TC-7 appears to be an efficacious barrier for reducing adhesion formation in the rabbit uterine horn model.

AB - Use of a resorbable barrier (TC-7) to reduce adhesion formation was examined in the rabbit uterine horn model. Early evaluation (four days) established that the material remained where initially placed. Examination at two, four and eight weeks postoperatively in both control and treated groups revealed that the extent of adhesion formation did not change as a function of time. When compared to control animals without TC-7, the treated rabbits had a significant reduction (P<.01) in postoperative adhesion formation. No complications from use of this fabric were noted, and no gross remnants were noted at the two-week time point. TC-7 appears to be an efficacious barrier for reducing adhesion formation in the rabbit uterine horn model.

UR - http://www.scopus.com/inward/record.url?scp=0023109619&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023109619&partnerID=8YFLogxK

M3 - Article

VL - 32

SP - 17

EP - 20

JO - Journal of Reproductive Medicine

JF - Journal of Reproductive Medicine

SN - 0024-7758

IS - 1

ER -