Clinical evaluation of the 'head-up' display of anesthesia data - Preliminary communication

Frank E Block, David O. Yablok, John S. McDonald

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

To solve the problem of monitoring the patient during administration of anesthesia, a commercially available headup display (HUD) was evaluated during one day of surgery at the Ohio State University Hospitals. This monitor is mounted on a headband worn by the anesthesiologist. It projects a monochrome image of monitor data directly into one eye. Eleven anesthesiologists tested the device. Most users were able to adjust to the monitor in about fifteen minutes. Nine of the testers expressed a desire to evaluate the monitor further. Their major complaints were that the connecting cable between the HUD and its computer was too short, the resolution of the monitor was inadequate, and the data on the screen were not organized in a familiar way. If these problems could be corrected, most users believed that this HUD could be a valuable tool to aid the anesthesiologist in the operating room.

Original languageEnglish (US)
Pages (from-to)21-24
Number of pages4
JournalInternational Journal of Clinical Monitoring and Computing
Volume12
Issue number1
DOIs
StatePublished - Feb 1 1995
Externally publishedYes

Fingerprint

Data Display
Anesthesia
Communication
Head
State Hospitals
Physiologic Monitoring
Operating Rooms
Ambulatory Surgical Procedures
Equipment and Supplies
Anesthesiologists

Keywords

  • display
  • head-up
  • human factors
  • monitoring
  • physiologic
  • private eye

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Critical Care and Intensive Care Medicine

Cite this

Clinical evaluation of the 'head-up' display of anesthesia data - Preliminary communication. / Block, Frank E; Yablok, David O.; McDonald, John S.

In: International Journal of Clinical Monitoring and Computing, Vol. 12, No. 1, 01.02.1995, p. 21-24.

Research output: Contribution to journalArticle

@article{1b1bb45a6fb14f5891318c22ab642163,
title = "Clinical evaluation of the 'head-up' display of anesthesia data - Preliminary communication",
abstract = "To solve the problem of monitoring the patient during administration of anesthesia, a commercially available headup display (HUD) was evaluated during one day of surgery at the Ohio State University Hospitals. This monitor is mounted on a headband worn by the anesthesiologist. It projects a monochrome image of monitor data directly into one eye. Eleven anesthesiologists tested the device. Most users were able to adjust to the monitor in about fifteen minutes. Nine of the testers expressed a desire to evaluate the monitor further. Their major complaints were that the connecting cable between the HUD and its computer was too short, the resolution of the monitor was inadequate, and the data on the screen were not organized in a familiar way. If these problems could be corrected, most users believed that this HUD could be a valuable tool to aid the anesthesiologist in the operating room.",
keywords = "display, head-up, human factors, monitoring, physiologic, private eye",
author = "Block, {Frank E} and Yablok, {David O.} and McDonald, {John S.}",
year = "1995",
month = "2",
day = "1",
doi = "10.1007/BF01142442",
language = "English (US)",
volume = "12",
pages = "21--24",
journal = "Journal of Clinical Monitoring and Computing",
issn = "1387-1307",
publisher = "Springer Netherlands",
number = "1",

}

TY - JOUR

T1 - Clinical evaluation of the 'head-up' display of anesthesia data - Preliminary communication

AU - Block, Frank E

AU - Yablok, David O.

AU - McDonald, John S.

PY - 1995/2/1

Y1 - 1995/2/1

N2 - To solve the problem of monitoring the patient during administration of anesthesia, a commercially available headup display (HUD) was evaluated during one day of surgery at the Ohio State University Hospitals. This monitor is mounted on a headband worn by the anesthesiologist. It projects a monochrome image of monitor data directly into one eye. Eleven anesthesiologists tested the device. Most users were able to adjust to the monitor in about fifteen minutes. Nine of the testers expressed a desire to evaluate the monitor further. Their major complaints were that the connecting cable between the HUD and its computer was too short, the resolution of the monitor was inadequate, and the data on the screen were not organized in a familiar way. If these problems could be corrected, most users believed that this HUD could be a valuable tool to aid the anesthesiologist in the operating room.

AB - To solve the problem of monitoring the patient during administration of anesthesia, a commercially available headup display (HUD) was evaluated during one day of surgery at the Ohio State University Hospitals. This monitor is mounted on a headband worn by the anesthesiologist. It projects a monochrome image of monitor data directly into one eye. Eleven anesthesiologists tested the device. Most users were able to adjust to the monitor in about fifteen minutes. Nine of the testers expressed a desire to evaluate the monitor further. Their major complaints were that the connecting cable between the HUD and its computer was too short, the resolution of the monitor was inadequate, and the data on the screen were not organized in a familiar way. If these problems could be corrected, most users believed that this HUD could be a valuable tool to aid the anesthesiologist in the operating room.

KW - display

KW - head-up

KW - human factors

KW - monitoring

KW - physiologic

KW - private eye

UR - http://www.scopus.com/inward/record.url?scp=0028951410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028951410&partnerID=8YFLogxK

U2 - 10.1007/BF01142442

DO - 10.1007/BF01142442

M3 - Article

VL - 12

SP - 21

EP - 24

JO - Journal of Clinical Monitoring and Computing

JF - Journal of Clinical Monitoring and Computing

SN - 1387-1307

IS - 1

ER -