Corpectomy and stabilization with methylmethacrylate in patients with metastatic disease of the spine: A technical note

Cargill Herley Alleyne, Gerald E. Rodts, Regis W. Haid

Research output: Contribution to journalArticle

22 Citations (Scopus)

Abstract

Corpectomy with methylmethacrylate reconstruction and stabilization in patients with metastatic disease of the spine has been performed for several years. Stainless steel Steinmann pins or K-wires are commonly used to facilitate fixation of the acrylic to the vertebral bodies above and below the resection site. The use of these ferromagnetic substances precludes the optimal use of magnetic resonance imaging in the postoperative period. We now report the use of commercially available titanium screws in conjunction with the methylmethacrylate to eliminate this problem and provide for improved postoperative imaging.

Original languageEnglish (US)
Pages (from-to)439-443
Number of pages5
JournalJournal of Spinal Disorders and Techniques
Volume8
Issue number6
StatePublished - Jan 1 1995
Externally publishedYes

Fingerprint

Methylmethacrylate
Spine
Stainless Steel
Titanium
Postoperative Period
Magnetic Resonance Imaging

Keywords

  • Corpectomy
  • Metastatic tumor
  • Methylmethacrylate spine stabilization
  • Titanium screws

ASJC Scopus subject areas

  • Clinical Neurology
  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Corpectomy and stabilization with methylmethacrylate in patients with metastatic disease of the spine : A technical note. / Alleyne, Cargill Herley; Rodts, Gerald E.; Haid, Regis W.

In: Journal of Spinal Disorders and Techniques, Vol. 8, No. 6, 01.01.1995, p. 439-443.

Research output: Contribution to journalArticle

@article{f74b20fe45a74ef2ab4f0c48f80e6c04,
title = "Corpectomy and stabilization with methylmethacrylate in patients with metastatic disease of the spine: A technical note",
abstract = "Corpectomy with methylmethacrylate reconstruction and stabilization in patients with metastatic disease of the spine has been performed for several years. Stainless steel Steinmann pins or K-wires are commonly used to facilitate fixation of the acrylic to the vertebral bodies above and below the resection site. The use of these ferromagnetic substances precludes the optimal use of magnetic resonance imaging in the postoperative period. We now report the use of commercially available titanium screws in conjunction with the methylmethacrylate to eliminate this problem and provide for improved postoperative imaging.",
keywords = "Corpectomy, Metastatic tumor, Methylmethacrylate spine stabilization, Titanium screws",
author = "Alleyne, {Cargill Herley} and Rodts, {Gerald E.} and Haid, {Regis W.}",
year = "1995",
month = "1",
day = "1",
language = "English (US)",
volume = "8",
pages = "439--443",
journal = "Journal of Spinal Disorders",
issn = "1536-0652",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - Corpectomy and stabilization with methylmethacrylate in patients with metastatic disease of the spine

T2 - A technical note

AU - Alleyne, Cargill Herley

AU - Rodts, Gerald E.

AU - Haid, Regis W.

PY - 1995/1/1

Y1 - 1995/1/1

N2 - Corpectomy with methylmethacrylate reconstruction and stabilization in patients with metastatic disease of the spine has been performed for several years. Stainless steel Steinmann pins or K-wires are commonly used to facilitate fixation of the acrylic to the vertebral bodies above and below the resection site. The use of these ferromagnetic substances precludes the optimal use of magnetic resonance imaging in the postoperative period. We now report the use of commercially available titanium screws in conjunction with the methylmethacrylate to eliminate this problem and provide for improved postoperative imaging.

AB - Corpectomy with methylmethacrylate reconstruction and stabilization in patients with metastatic disease of the spine has been performed for several years. Stainless steel Steinmann pins or K-wires are commonly used to facilitate fixation of the acrylic to the vertebral bodies above and below the resection site. The use of these ferromagnetic substances precludes the optimal use of magnetic resonance imaging in the postoperative period. We now report the use of commercially available titanium screws in conjunction with the methylmethacrylate to eliminate this problem and provide for improved postoperative imaging.

KW - Corpectomy

KW - Metastatic tumor

KW - Methylmethacrylate spine stabilization

KW - Titanium screws

UR - http://www.scopus.com/inward/record.url?scp=0028808895&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028808895&partnerID=8YFLogxK

M3 - Article

C2 - 8605416

AN - SCOPUS:0028808895

VL - 8

SP - 439

EP - 443

JO - Journal of Spinal Disorders

JF - Journal of Spinal Disorders

SN - 1536-0652

IS - 6

ER -