Curing kinetics of a photo-polymerized dental sealant

Ralph D. Warnock, Frederick Rueggeberg

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Purpose: To evaluate the effect of using a variety of light-curing sources on the extent (monomer conversion) and rate of cure of a light-cured dental sealant. Infrared spectroscopy recorded real-time polymerization of a self-cured and a light-cured sealant when the latter was exposed using manufacturer's recommendations [quartz-tungsten-halogen (QTH)] for 20 seconds as well as to other light sources: high intensity QTH, plasma arc light (PAC), and second-generation blue light emitting diode (LED) units. Specimens were heated to 37°C and the degree and rate of conversion were recorded at each second for 300 seconds. Conversion extent and rate were compared among light units as well as to the self-curing product. Five replications for each test condition were performed. After 300 seconds, self-curing product conversion was equivalent to all light-exposed specimens. The self-cured rate of cure was significantly lower than all light-cured scenarios. The high intensity QTH light provided equivalent conversion as conventional 20-second QTH exposure (control) in only 10 seconds. The PAC light required similar exposure time as conventional QTH treatment. Second-generation blue LED units reached conversion similar to control in only 10 seconds, while one light required only 5 seconds' exposure.

Original languageEnglish (US)
Pages (from-to)457-461
Number of pages5
JournalAmerican Journal of Dentistry
Volume17
Issue number6
StatePublished - Dec 1 2004

Fingerprint

Pit and Fissure Sealants
Light
Tungsten
Quartz
Halogens
Polymerization

ASJC Scopus subject areas

  • Medicine(all)
  • Dentistry(all)

Cite this

Curing kinetics of a photo-polymerized dental sealant. / Warnock, Ralph D.; Rueggeberg, Frederick.

In: American Journal of Dentistry, Vol. 17, No. 6, 01.12.2004, p. 457-461.

Research output: Contribution to journalArticle

@article{503bc75778d04f009fd40c5634159580,
title = "Curing kinetics of a photo-polymerized dental sealant",
abstract = "Purpose: To evaluate the effect of using a variety of light-curing sources on the extent (monomer conversion) and rate of cure of a light-cured dental sealant. Infrared spectroscopy recorded real-time polymerization of a self-cured and a light-cured sealant when the latter was exposed using manufacturer's recommendations [quartz-tungsten-halogen (QTH)] for 20 seconds as well as to other light sources: high intensity QTH, plasma arc light (PAC), and second-generation blue light emitting diode (LED) units. Specimens were heated to 37°C and the degree and rate of conversion were recorded at each second for 300 seconds. Conversion extent and rate were compared among light units as well as to the self-curing product. Five replications for each test condition were performed. After 300 seconds, self-curing product conversion was equivalent to all light-exposed specimens. The self-cured rate of cure was significantly lower than all light-cured scenarios. The high intensity QTH light provided equivalent conversion as conventional 20-second QTH exposure (control) in only 10 seconds. The PAC light required similar exposure time as conventional QTH treatment. Second-generation blue LED units reached conversion similar to control in only 10 seconds, while one light required only 5 seconds' exposure.",
author = "Warnock, {Ralph D.} and Frederick Rueggeberg",
year = "2004",
month = "12",
day = "1",
language = "English (US)",
volume = "17",
pages = "457--461",
journal = "American Journal of Dentistry",
issn = "0894-8275",
publisher = "Mosher and Linder, Inc",
number = "6",

}

TY - JOUR

T1 - Curing kinetics of a photo-polymerized dental sealant

AU - Warnock, Ralph D.

AU - Rueggeberg, Frederick

PY - 2004/12/1

Y1 - 2004/12/1

N2 - Purpose: To evaluate the effect of using a variety of light-curing sources on the extent (monomer conversion) and rate of cure of a light-cured dental sealant. Infrared spectroscopy recorded real-time polymerization of a self-cured and a light-cured sealant when the latter was exposed using manufacturer's recommendations [quartz-tungsten-halogen (QTH)] for 20 seconds as well as to other light sources: high intensity QTH, plasma arc light (PAC), and second-generation blue light emitting diode (LED) units. Specimens were heated to 37°C and the degree and rate of conversion were recorded at each second for 300 seconds. Conversion extent and rate were compared among light units as well as to the self-curing product. Five replications for each test condition were performed. After 300 seconds, self-curing product conversion was equivalent to all light-exposed specimens. The self-cured rate of cure was significantly lower than all light-cured scenarios. The high intensity QTH light provided equivalent conversion as conventional 20-second QTH exposure (control) in only 10 seconds. The PAC light required similar exposure time as conventional QTH treatment. Second-generation blue LED units reached conversion similar to control in only 10 seconds, while one light required only 5 seconds' exposure.

AB - Purpose: To evaluate the effect of using a variety of light-curing sources on the extent (monomer conversion) and rate of cure of a light-cured dental sealant. Infrared spectroscopy recorded real-time polymerization of a self-cured and a light-cured sealant when the latter was exposed using manufacturer's recommendations [quartz-tungsten-halogen (QTH)] for 20 seconds as well as to other light sources: high intensity QTH, plasma arc light (PAC), and second-generation blue light emitting diode (LED) units. Specimens were heated to 37°C and the degree and rate of conversion were recorded at each second for 300 seconds. Conversion extent and rate were compared among light units as well as to the self-curing product. Five replications for each test condition were performed. After 300 seconds, self-curing product conversion was equivalent to all light-exposed specimens. The self-cured rate of cure was significantly lower than all light-cured scenarios. The high intensity QTH light provided equivalent conversion as conventional 20-second QTH exposure (control) in only 10 seconds. The PAC light required similar exposure time as conventional QTH treatment. Second-generation blue LED units reached conversion similar to control in only 10 seconds, while one light required only 5 seconds' exposure.

UR - http://www.scopus.com/inward/record.url?scp=14544284559&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=14544284559&partnerID=8YFLogxK

M3 - Article

C2 - 15724761

AN - SCOPUS:14544284559

VL - 17

SP - 457

EP - 461

JO - American Journal of Dentistry

JF - American Journal of Dentistry

SN - 0894-8275

IS - 6

ER -