Abstract

The purpose of this study was to determine the accuracy of preoperative templating of primary, noncemented femoral components. A retrospective review of charts and radiographs was performed on 74 hips in 64 patients who had undergone either noncemented total hip arthroplasty (THA) or placement of an endoprosthesis (including bipolar). Preoperative radiographs were templated by a total joint arthroplasty attending surgeon, a senior orthopaedic resident, and a junior resident. The templated size corresponded to the actual femoral implant used in approximately 50% of cases. When femoral prostheses within one size above or below the templated size were included, the accuracy of preoperative templating rose to 88-95%. When implants within two sizes of the templated size were included, the accuracy approached 100%. Factors associated with discrepancies in the size of femoral stem used included placement of an undersized implant, presence of metal hardware that obscured the ability to template accurately, proximal bone deformity, sclerotic bone, acute femoral neck fracture, and inadequate preoperative radiographs. The accuracy of templating increased gradually with the level of training. The most experienced investigator was able to template within one size of the actual implant used in 95% of cases, compared with 88% and 82% for the less experienced investigators. Acute femoral neck fractures and proximal bone deformity were associated with the largest discrepancies in templated sizes.

Original languageEnglish (US)
Pages (from-to)507-513
Number of pages7
JournalThe Journal of Arthroplasty
Volume10
Issue number4
DOIs
StatePublished - Jan 1 1995

Fingerprint

Thigh
Prostheses and Implants
Femoral Neck Fractures
Bone and Bones
Arthroplasty
Hip
Research Personnel
Orthopedics
Joints
Metals

Keywords

  • accuracy
  • femoral stem size
  • preoperative templating

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Surgery

Cite this

Determination of accuracy of preoperative templating of noncemented femoral prostheses. / Carter, Larry W.; Stovall, Don O.; Young, Timothy R.

In: The Journal of Arthroplasty, Vol. 10, No. 4, 01.01.1995, p. 507-513.

Research output: Contribution to journalArticle

Carter, Larry W. ; Stovall, Don O. ; Young, Timothy R. / Determination of accuracy of preoperative templating of noncemented femoral prostheses. In: The Journal of Arthroplasty. 1995 ; Vol. 10, No. 4. pp. 507-513.
@article{7ce8173805cf4fe1a8c647aa770c4497,
title = "Determination of accuracy of preoperative templating of noncemented femoral prostheses",
abstract = "The purpose of this study was to determine the accuracy of preoperative templating of primary, noncemented femoral components. A retrospective review of charts and radiographs was performed on 74 hips in 64 patients who had undergone either noncemented total hip arthroplasty (THA) or placement of an endoprosthesis (including bipolar). Preoperative radiographs were templated by a total joint arthroplasty attending surgeon, a senior orthopaedic resident, and a junior resident. The templated size corresponded to the actual femoral implant used in approximately 50{\%} of cases. When femoral prostheses within one size above or below the templated size were included, the accuracy of preoperative templating rose to 88-95{\%}. When implants within two sizes of the templated size were included, the accuracy approached 100{\%}. Factors associated with discrepancies in the size of femoral stem used included placement of an undersized implant, presence of metal hardware that obscured the ability to template accurately, proximal bone deformity, sclerotic bone, acute femoral neck fracture, and inadequate preoperative radiographs. The accuracy of templating increased gradually with the level of training. The most experienced investigator was able to template within one size of the actual implant used in 95{\%} of cases, compared with 88{\%} and 82{\%} for the less experienced investigators. Acute femoral neck fractures and proximal bone deformity were associated with the largest discrepancies in templated sizes.",
keywords = "accuracy, femoral stem size, preoperative templating",
author = "Carter, {Larry W.} and Stovall, {Don O.} and Young, {Timothy R}",
year = "1995",
month = "1",
day = "1",
doi = "10.1016/S0883-5403(05)80153-6",
language = "English (US)",
volume = "10",
pages = "507--513",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "4",

}

TY - JOUR

T1 - Determination of accuracy of preoperative templating of noncemented femoral prostheses

AU - Carter, Larry W.

AU - Stovall, Don O.

AU - Young, Timothy R

PY - 1995/1/1

Y1 - 1995/1/1

N2 - The purpose of this study was to determine the accuracy of preoperative templating of primary, noncemented femoral components. A retrospective review of charts and radiographs was performed on 74 hips in 64 patients who had undergone either noncemented total hip arthroplasty (THA) or placement of an endoprosthesis (including bipolar). Preoperative radiographs were templated by a total joint arthroplasty attending surgeon, a senior orthopaedic resident, and a junior resident. The templated size corresponded to the actual femoral implant used in approximately 50% of cases. When femoral prostheses within one size above or below the templated size were included, the accuracy of preoperative templating rose to 88-95%. When implants within two sizes of the templated size were included, the accuracy approached 100%. Factors associated with discrepancies in the size of femoral stem used included placement of an undersized implant, presence of metal hardware that obscured the ability to template accurately, proximal bone deformity, sclerotic bone, acute femoral neck fracture, and inadequate preoperative radiographs. The accuracy of templating increased gradually with the level of training. The most experienced investigator was able to template within one size of the actual implant used in 95% of cases, compared with 88% and 82% for the less experienced investigators. Acute femoral neck fractures and proximal bone deformity were associated with the largest discrepancies in templated sizes.

AB - The purpose of this study was to determine the accuracy of preoperative templating of primary, noncemented femoral components. A retrospective review of charts and radiographs was performed on 74 hips in 64 patients who had undergone either noncemented total hip arthroplasty (THA) or placement of an endoprosthesis (including bipolar). Preoperative radiographs were templated by a total joint arthroplasty attending surgeon, a senior orthopaedic resident, and a junior resident. The templated size corresponded to the actual femoral implant used in approximately 50% of cases. When femoral prostheses within one size above or below the templated size were included, the accuracy of preoperative templating rose to 88-95%. When implants within two sizes of the templated size were included, the accuracy approached 100%. Factors associated with discrepancies in the size of femoral stem used included placement of an undersized implant, presence of metal hardware that obscured the ability to template accurately, proximal bone deformity, sclerotic bone, acute femoral neck fracture, and inadequate preoperative radiographs. The accuracy of templating increased gradually with the level of training. The most experienced investigator was able to template within one size of the actual implant used in 95% of cases, compared with 88% and 82% for the less experienced investigators. Acute femoral neck fractures and proximal bone deformity were associated with the largest discrepancies in templated sizes.

KW - accuracy

KW - femoral stem size

KW - preoperative templating

UR - http://www.scopus.com/inward/record.url?scp=0029026133&partnerID=8YFLogxK