Effect of cubic leucite stabilization on the flexural strength of feldspathic dental porcelain

I. L. Denry, Jr Mackert J.R., J. A. Holloway, S. F. Rosenstiel

Research output: Contribution to journalArticle

81 Citations (Scopus)

Abstract

Previous studies (Mackert and Evans, 1993) have shown that, when feldspathic dental porcelain is cooled, leucite undergoes a transformation from cubic to tetragonal, associated with a 1.2% volume contraction. This contraction leads to the formation of microcracks in and around the crystals and the development of tangential compressive stresses around the crystals. Our aim was to stabilize increasing amounts of the cubic form of leucite in a leucite-reinforced dental porcelain, evaluate its effect on the flexural strength, and characterize its microstructure. The hypothesis was that in the absence of crystallographic transformation, the contraction of the leucite crystals would be lower, thereby limiting the formation of microcracks and minimizing the development of tangential compressive stresses around the leucite particles. We prepared 8 porcelain compositions by mixing increasing amounts of either leucite (KAlSi2O6) or pollucite (CsAlSi2O6) with Optec HSP porcelain (Jeneric/Pentron Inc., Wallingford, CT). Porcelain disks were made from each composition (n = 10 per group). X-ray diffraction analyses showed that the amount of stabilized leucite increased with the amount of pollucite added. The microstructure of the specimens containing tetragonal leucite was characterized by twinned leucite crystals, whereas no twinning was observed in the specimens containing cubic leucite. The evaluation of crack deflection showed that significantly less deflection occurred in the specimens containing cubic leucite. The mean biaxial flexural strength for the group corresponding to 22.2 wt% added pollucite, fired at 1038°C, was significantly lower than that for the control group. The group corresponding to 22.2 wt% added leucite fired at 1150°C exhibited a mean biaxial flexural strength significantly higher than that of all other groups that were not significantly different from the control group. Overall, the stabilization of cubic leucite reduced the flexural strength and the number of crack deflections in leucite-reinforced porcelain. Apparently, the development of tangential compressive stresses around the leucite crystals when cooled is responsible for a significant amount of strengthening of feldspathic dental porcelain.

Original languageEnglish (US)
Pages (from-to)1928-1935
Number of pages8
JournalJournal of Dental Research
Volume75
Issue number12
DOIs
StatePublished - Jan 1 1996

Fingerprint

Dental Porcelain
leucite
Control Groups
X-Ray Diffraction

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Effect of cubic leucite stabilization on the flexural strength of feldspathic dental porcelain. / Denry, I. L.; Mackert J.R., Jr; Holloway, J. A.; Rosenstiel, S. F.

In: Journal of Dental Research, Vol. 75, No. 12, 01.01.1996, p. 1928-1935.

Research output: Contribution to journalArticle

Denry, I. L. ; Mackert J.R., Jr ; Holloway, J. A. ; Rosenstiel, S. F. / Effect of cubic leucite stabilization on the flexural strength of feldspathic dental porcelain. In: Journal of Dental Research. 1996 ; Vol. 75, No. 12. pp. 1928-1935.
@article{cbabe1d4937841ed9adc4be31505b65f,
title = "Effect of cubic leucite stabilization on the flexural strength of feldspathic dental porcelain",
abstract = "Previous studies (Mackert and Evans, 1993) have shown that, when feldspathic dental porcelain is cooled, leucite undergoes a transformation from cubic to tetragonal, associated with a 1.2{\%} volume contraction. This contraction leads to the formation of microcracks in and around the crystals and the development of tangential compressive stresses around the crystals. Our aim was to stabilize increasing amounts of the cubic form of leucite in a leucite-reinforced dental porcelain, evaluate its effect on the flexural strength, and characterize its microstructure. The hypothesis was that in the absence of crystallographic transformation, the contraction of the leucite crystals would be lower, thereby limiting the formation of microcracks and minimizing the development of tangential compressive stresses around the leucite particles. We prepared 8 porcelain compositions by mixing increasing amounts of either leucite (KAlSi2O6) or pollucite (CsAlSi2O6) with Optec HSP porcelain (Jeneric/Pentron Inc., Wallingford, CT). Porcelain disks were made from each composition (n = 10 per group). X-ray diffraction analyses showed that the amount of stabilized leucite increased with the amount of pollucite added. The microstructure of the specimens containing tetragonal leucite was characterized by twinned leucite crystals, whereas no twinning was observed in the specimens containing cubic leucite. The evaluation of crack deflection showed that significantly less deflection occurred in the specimens containing cubic leucite. The mean biaxial flexural strength for the group corresponding to 22.2 wt{\%} added pollucite, fired at 1038°C, was significantly lower than that for the control group. The group corresponding to 22.2 wt{\%} added leucite fired at 1150°C exhibited a mean biaxial flexural strength significantly higher than that of all other groups that were not significantly different from the control group. Overall, the stabilization of cubic leucite reduced the flexural strength and the number of crack deflections in leucite-reinforced porcelain. Apparently, the development of tangential compressive stresses around the leucite crystals when cooled is responsible for a significant amount of strengthening of feldspathic dental porcelain.",
author = "Denry, {I. L.} and {Mackert J.R.}, Jr and Holloway, {J. A.} and Rosenstiel, {S. F.}",
year = "1996",
month = "1",
day = "1",
doi = "10.1177/00220345960750120301",
language = "English (US)",
volume = "75",
pages = "1928--1935",
journal = "Journal of Dental Research",
issn = "0022-0345",
publisher = "SAGE Publications Inc.",
number = "12",

}

TY - JOUR

T1 - Effect of cubic leucite stabilization on the flexural strength of feldspathic dental porcelain

AU - Denry, I. L.

AU - Mackert J.R., Jr

AU - Holloway, J. A.

AU - Rosenstiel, S. F.

PY - 1996/1/1

Y1 - 1996/1/1

N2 - Previous studies (Mackert and Evans, 1993) have shown that, when feldspathic dental porcelain is cooled, leucite undergoes a transformation from cubic to tetragonal, associated with a 1.2% volume contraction. This contraction leads to the formation of microcracks in and around the crystals and the development of tangential compressive stresses around the crystals. Our aim was to stabilize increasing amounts of the cubic form of leucite in a leucite-reinforced dental porcelain, evaluate its effect on the flexural strength, and characterize its microstructure. The hypothesis was that in the absence of crystallographic transformation, the contraction of the leucite crystals would be lower, thereby limiting the formation of microcracks and minimizing the development of tangential compressive stresses around the leucite particles. We prepared 8 porcelain compositions by mixing increasing amounts of either leucite (KAlSi2O6) or pollucite (CsAlSi2O6) with Optec HSP porcelain (Jeneric/Pentron Inc., Wallingford, CT). Porcelain disks were made from each composition (n = 10 per group). X-ray diffraction analyses showed that the amount of stabilized leucite increased with the amount of pollucite added. The microstructure of the specimens containing tetragonal leucite was characterized by twinned leucite crystals, whereas no twinning was observed in the specimens containing cubic leucite. The evaluation of crack deflection showed that significantly less deflection occurred in the specimens containing cubic leucite. The mean biaxial flexural strength for the group corresponding to 22.2 wt% added pollucite, fired at 1038°C, was significantly lower than that for the control group. The group corresponding to 22.2 wt% added leucite fired at 1150°C exhibited a mean biaxial flexural strength significantly higher than that of all other groups that were not significantly different from the control group. Overall, the stabilization of cubic leucite reduced the flexural strength and the number of crack deflections in leucite-reinforced porcelain. Apparently, the development of tangential compressive stresses around the leucite crystals when cooled is responsible for a significant amount of strengthening of feldspathic dental porcelain.

AB - Previous studies (Mackert and Evans, 1993) have shown that, when feldspathic dental porcelain is cooled, leucite undergoes a transformation from cubic to tetragonal, associated with a 1.2% volume contraction. This contraction leads to the formation of microcracks in and around the crystals and the development of tangential compressive stresses around the crystals. Our aim was to stabilize increasing amounts of the cubic form of leucite in a leucite-reinforced dental porcelain, evaluate its effect on the flexural strength, and characterize its microstructure. The hypothesis was that in the absence of crystallographic transformation, the contraction of the leucite crystals would be lower, thereby limiting the formation of microcracks and minimizing the development of tangential compressive stresses around the leucite particles. We prepared 8 porcelain compositions by mixing increasing amounts of either leucite (KAlSi2O6) or pollucite (CsAlSi2O6) with Optec HSP porcelain (Jeneric/Pentron Inc., Wallingford, CT). Porcelain disks were made from each composition (n = 10 per group). X-ray diffraction analyses showed that the amount of stabilized leucite increased with the amount of pollucite added. The microstructure of the specimens containing tetragonal leucite was characterized by twinned leucite crystals, whereas no twinning was observed in the specimens containing cubic leucite. The evaluation of crack deflection showed that significantly less deflection occurred in the specimens containing cubic leucite. The mean biaxial flexural strength for the group corresponding to 22.2 wt% added pollucite, fired at 1038°C, was significantly lower than that for the control group. The group corresponding to 22.2 wt% added leucite fired at 1150°C exhibited a mean biaxial flexural strength significantly higher than that of all other groups that were not significantly different from the control group. Overall, the stabilization of cubic leucite reduced the flexural strength and the number of crack deflections in leucite-reinforced porcelain. Apparently, the development of tangential compressive stresses around the leucite crystals when cooled is responsible for a significant amount of strengthening of feldspathic dental porcelain.

UR - http://www.scopus.com/inward/record.url?scp=0030307205&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030307205&partnerID=8YFLogxK

U2 - 10.1177/00220345960750120301

DO - 10.1177/00220345960750120301

M3 - Article

C2 - 9033446

AN - SCOPUS:0030307205

VL - 75

SP - 1928

EP - 1935

JO - Journal of Dental Research

JF - Journal of Dental Research

SN - 0022-0345

IS - 12

ER -