The use of computers to aid in instruction and help decrease the subjective component of assessment is steadily increasing. One of the potential barriers to the effective utilization of CAD/CAM technology for assessment purposes is the efficient scanning of the teeth being used for comparison. The purpose of this pilot study was to determine if the use of different typodonts, of the same make and model, has any significant effect on the percent comparison results when using E4D Compare. Tooth #30 was prepared by a faculty member to represent what dental students at Georgia Regents University are taught as the ideal preparation for a full gold crown. Ten typodonts of the same make and model were selected for comparison. Three different examples of students' preparations were scanned and compared to the ideal preparation. Each of the three student preparations was subjected to ten trials (occasions), one for each typodont, at five tolerance levels: 0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm, and 0.5 mm. The intraclass correlation coefficient (ICC) was used to measure the intrarater agreement among the typodonts at the various tolerance levels. The agreement coefficients (0.971-0.984) indicated very little variability attributable to the use of a different typodont. The high agreement coefficients achieved using different typodonts of the same make and model provide evidence for the interchangeability of typodonts when assessing a student's performance in the preclinical simulation environment.

Original languageEnglish (US)
Pages (from-to)705-710
Number of pages6
JournalJournal of dental education
Volume79
Issue number6
StatePublished - Jun 1 2015

Fingerprint

Dental Students
Students
Tooth
tolerance
Computer-Aided Design
Biomedical Technology Assessment
student
CAM
Crowns
Gold
CAD
gold
utilization
instruction
simulation
performance
evidence

Keywords

  • Assessment
  • CAD/CAM
  • Dental education
  • Grading
  • Typodont

ASJC Scopus subject areas

  • Education
  • Dentistry(all)

Cite this

@article{a4b9450046e2436288b6ff8e56de9844,
title = "Effect of employing different typodonts when using E4D compare for dental student assessment",
abstract = "The use of computers to aid in instruction and help decrease the subjective component of assessment is steadily increasing. One of the potential barriers to the effective utilization of CAD/CAM technology for assessment purposes is the efficient scanning of the teeth being used for comparison. The purpose of this pilot study was to determine if the use of different typodonts, of the same make and model, has any significant effect on the percent comparison results when using E4D Compare. Tooth #30 was prepared by a faculty member to represent what dental students at Georgia Regents University are taught as the ideal preparation for a full gold crown. Ten typodonts of the same make and model were selected for comparison. Three different examples of students' preparations were scanned and compared to the ideal preparation. Each of the three student preparations was subjected to ten trials (occasions), one for each typodont, at five tolerance levels: 0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm, and 0.5 mm. The intraclass correlation coefficient (ICC) was used to measure the intrarater agreement among the typodonts at the various tolerance levels. The agreement coefficients (0.971-0.984) indicated very little variability attributable to the use of a different typodont. The high agreement coefficients achieved using different typodonts of the same make and model provide evidence for the interchangeability of typodonts when assessing a student's performance in the preclinical simulation environment.",
keywords = "Assessment, CAD/CAM, Dental education, Grading, Typodont",
author = "Callan, {Richard S.} and Cooper, {Jeril R.} and Young, {Nancy B.} and Mollica, {Anthony G.} and Furness, {Alan R.} and Looney, {Stephen W.}",
year = "2015",
month = "6",
day = "1",
language = "English (US)",
volume = "79",
pages = "705--710",
journal = "Journal of Dental Education",
issn = "0022-0337",
publisher = "American Dental Education Association",
number = "6",

}

TY - JOUR

T1 - Effect of employing different typodonts when using E4D compare for dental student assessment

AU - Callan, Richard S.

AU - Cooper, Jeril R.

AU - Young, Nancy B.

AU - Mollica, Anthony G.

AU - Furness, Alan R.

AU - Looney, Stephen W.

PY - 2015/6/1

Y1 - 2015/6/1

N2 - The use of computers to aid in instruction and help decrease the subjective component of assessment is steadily increasing. One of the potential barriers to the effective utilization of CAD/CAM technology for assessment purposes is the efficient scanning of the teeth being used for comparison. The purpose of this pilot study was to determine if the use of different typodonts, of the same make and model, has any significant effect on the percent comparison results when using E4D Compare. Tooth #30 was prepared by a faculty member to represent what dental students at Georgia Regents University are taught as the ideal preparation for a full gold crown. Ten typodonts of the same make and model were selected for comparison. Three different examples of students' preparations were scanned and compared to the ideal preparation. Each of the three student preparations was subjected to ten trials (occasions), one for each typodont, at five tolerance levels: 0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm, and 0.5 mm. The intraclass correlation coefficient (ICC) was used to measure the intrarater agreement among the typodonts at the various tolerance levels. The agreement coefficients (0.971-0.984) indicated very little variability attributable to the use of a different typodont. The high agreement coefficients achieved using different typodonts of the same make and model provide evidence for the interchangeability of typodonts when assessing a student's performance in the preclinical simulation environment.

AB - The use of computers to aid in instruction and help decrease the subjective component of assessment is steadily increasing. One of the potential barriers to the effective utilization of CAD/CAM technology for assessment purposes is the efficient scanning of the teeth being used for comparison. The purpose of this pilot study was to determine if the use of different typodonts, of the same make and model, has any significant effect on the percent comparison results when using E4D Compare. Tooth #30 was prepared by a faculty member to represent what dental students at Georgia Regents University are taught as the ideal preparation for a full gold crown. Ten typodonts of the same make and model were selected for comparison. Three different examples of students' preparations were scanned and compared to the ideal preparation. Each of the three student preparations was subjected to ten trials (occasions), one for each typodont, at five tolerance levels: 0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm, and 0.5 mm. The intraclass correlation coefficient (ICC) was used to measure the intrarater agreement among the typodonts at the various tolerance levels. The agreement coefficients (0.971-0.984) indicated very little variability attributable to the use of a different typodont. The high agreement coefficients achieved using different typodonts of the same make and model provide evidence for the interchangeability of typodonts when assessing a student's performance in the preclinical simulation environment.

KW - Assessment

KW - CAD/CAM

KW - Dental education

KW - Grading

KW - Typodont

UR - http://www.scopus.com/inward/record.url?scp=84938904027&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84938904027&partnerID=8YFLogxK

M3 - Article

C2 - 26034036

AN - SCOPUS:84938904027

VL - 79

SP - 705

EP - 710

JO - Journal of Dental Education

JF - Journal of Dental Education

SN - 0022-0337

IS - 6

ER -