Abstract
The purpose of this study was to examine the effect of varying the powder/liquid ratio on the physical properties and the degree and rate of curing of C&B Metabond cement. The powder/liquid ratios evaluated had no effect on the tensile bond strength of Rexillium III to etched enamel or on the retention of cemented full cast crowns. The higher P/L ratio resulted in an increased vertical displacement of the cemented crowns. The rate of monomer conversion and the total conversion were not affected significantly by the different P/L ratios.
Original language | English (US) |
---|---|
Pages (from-to) | 77-80 |
Number of pages | 4 |
Journal | American journal of dentistry |
Volume | 6 |
Issue number | 2 |
State | Published - Apr 1 1993 |
ASJC Scopus subject areas
- General Dentistry