Eighteen-month clinical performance of a self-etching primer in unprepared Class V resin restorations

W. W. Brackett, M. G. Brackett, A. Dib, G. Franco, H. Estudillo

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

This study evaluated the clinical performance of unprepared Class V resin composites, placed using a self-etching primer and a single-bottle adhesive, over a period of 18 months. Thirty-eight pairs of restorations of Renew hybrid resin composite (BISCO, Inc) were placed using adhesives from the same manufacturer in caries-free cervical erosion/abfraction lesions. Based on insensitivity to air, the dentin in 76% of these lesions was considered to be sclerotic. The restorations were placed without abrasion of tooth surfaces, except for cleaning with plain pumice. One of each pair was placed using Tyrian, a self-etching primer and the other was placed using One-Step, a single-bottle adhesive placed after acid etching. Both the etchant and self-etching primer were applied for 20 seconds. The restorations were clinically evaluated at baseline, 6, 12 and 18 months, using modified Ryge/USPHS criteria. For both adhesives, very low retention of 50% to 56% of the restorations was observed over 18 months, leading to the conclusion that tooth surfaces must receive some additional treatment prior to restoration with these adhesives. No statistically significant difference (p=0.75) between the two adhesives was observed in overall performance, and dentinal sclerosis and axial depth did not appear to be important factors in the study.

Original languageEnglish (US)
Pages (from-to)424-429
Number of pages6
JournalOperative Dentistry
Volume30
Issue number4
StatePublished - Jul 1 2005

Fingerprint

Adhesives
Composite Resins
Tooth Abrasion
Root Caries
United States Public Health Service
Sclerosis
Dentin
Tooth
Air
Acids

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Eighteen-month clinical performance of a self-etching primer in unprepared Class V resin restorations. / Brackett, W. W.; Brackett, M. G.; Dib, A.; Franco, G.; Estudillo, H.

In: Operative Dentistry, Vol. 30, No. 4, 01.07.2005, p. 424-429.

Research output: Contribution to journalArticle

@article{14f6d0afc87c4358ba4e3f72cdc7c844,
title = "Eighteen-month clinical performance of a self-etching primer in unprepared Class V resin restorations",
abstract = "This study evaluated the clinical performance of unprepared Class V resin composites, placed using a self-etching primer and a single-bottle adhesive, over a period of 18 months. Thirty-eight pairs of restorations of Renew hybrid resin composite (BISCO, Inc) were placed using adhesives from the same manufacturer in caries-free cervical erosion/abfraction lesions. Based on insensitivity to air, the dentin in 76{\%} of these lesions was considered to be sclerotic. The restorations were placed without abrasion of tooth surfaces, except for cleaning with plain pumice. One of each pair was placed using Tyrian, a self-etching primer and the other was placed using One-Step, a single-bottle adhesive placed after acid etching. Both the etchant and self-etching primer were applied for 20 seconds. The restorations were clinically evaluated at baseline, 6, 12 and 18 months, using modified Ryge/USPHS criteria. For both adhesives, very low retention of 50{\%} to 56{\%} of the restorations was observed over 18 months, leading to the conclusion that tooth surfaces must receive some additional treatment prior to restoration with these adhesives. No statistically significant difference (p=0.75) between the two adhesives was observed in overall performance, and dentinal sclerosis and axial depth did not appear to be important factors in the study.",
author = "Brackett, {W. W.} and Brackett, {M. G.} and A. Dib and G. Franco and H. Estudillo",
year = "2005",
month = "7",
day = "1",
language = "English (US)",
volume = "30",
pages = "424--429",
journal = "Operative Dentistry",
issn = "0361-7734",
publisher = "Indiana University School of Dentistry",
number = "4",

}

TY - JOUR

T1 - Eighteen-month clinical performance of a self-etching primer in unprepared Class V resin restorations

AU - Brackett, W. W.

AU - Brackett, M. G.

AU - Dib, A.

AU - Franco, G.

AU - Estudillo, H.

PY - 2005/7/1

Y1 - 2005/7/1

N2 - This study evaluated the clinical performance of unprepared Class V resin composites, placed using a self-etching primer and a single-bottle adhesive, over a period of 18 months. Thirty-eight pairs of restorations of Renew hybrid resin composite (BISCO, Inc) were placed using adhesives from the same manufacturer in caries-free cervical erosion/abfraction lesions. Based on insensitivity to air, the dentin in 76% of these lesions was considered to be sclerotic. The restorations were placed without abrasion of tooth surfaces, except for cleaning with plain pumice. One of each pair was placed using Tyrian, a self-etching primer and the other was placed using One-Step, a single-bottle adhesive placed after acid etching. Both the etchant and self-etching primer were applied for 20 seconds. The restorations were clinically evaluated at baseline, 6, 12 and 18 months, using modified Ryge/USPHS criteria. For both adhesives, very low retention of 50% to 56% of the restorations was observed over 18 months, leading to the conclusion that tooth surfaces must receive some additional treatment prior to restoration with these adhesives. No statistically significant difference (p=0.75) between the two adhesives was observed in overall performance, and dentinal sclerosis and axial depth did not appear to be important factors in the study.

AB - This study evaluated the clinical performance of unprepared Class V resin composites, placed using a self-etching primer and a single-bottle adhesive, over a period of 18 months. Thirty-eight pairs of restorations of Renew hybrid resin composite (BISCO, Inc) were placed using adhesives from the same manufacturer in caries-free cervical erosion/abfraction lesions. Based on insensitivity to air, the dentin in 76% of these lesions was considered to be sclerotic. The restorations were placed without abrasion of tooth surfaces, except for cleaning with plain pumice. One of each pair was placed using Tyrian, a self-etching primer and the other was placed using One-Step, a single-bottle adhesive placed after acid etching. Both the etchant and self-etching primer were applied for 20 seconds. The restorations were clinically evaluated at baseline, 6, 12 and 18 months, using modified Ryge/USPHS criteria. For both adhesives, very low retention of 50% to 56% of the restorations was observed over 18 months, leading to the conclusion that tooth surfaces must receive some additional treatment prior to restoration with these adhesives. No statistically significant difference (p=0.75) between the two adhesives was observed in overall performance, and dentinal sclerosis and axial depth did not appear to be important factors in the study.

UR - http://www.scopus.com/inward/record.url?scp=22944487934&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=22944487934&partnerID=8YFLogxK

M3 - Article

C2 - 16130861

AN - SCOPUS:22944487934

VL - 30

SP - 424

EP - 429

JO - Operative Dentistry

JF - Operative Dentistry

SN - 0361-7734

IS - 4

ER -