Evaluation of the effect of water-uptake on the impedance of dental resins

Bakul Wadgaonkar, Shuichi Ito, Nadia Svizero, David Elrod, Stephen Foulger, Robert Rodgers, Yoshiki Oshida, Kevin Kirkland, Jeremy Sword, Frederick Rueggeberg, Franklin Chi Meng Tay, David Henry Pashley

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Electrical impedance spectroscopy (EIS) offers a quantitative method of measuring the stability of resin films in aqueous solution over time. Purpose: The purpose of this study was to measure the EIS of five experimental dental adhesive films (ca. 17 μm thick) of increasing hydrophilicity (ranked by their Hoy's solubility parameters), and how much these values change over 3 weeks in aqueous buffer. Methods: The resin films were placed in a U-shaped chamber and a pair of Ag-AgCl electrodes was used for EIS. The EIS results were confirmed by immersing the films in 50% AgNO3 for 24 h to trace the distribution of any water absorption into the resins by TEM observations. Results: The resistance (Rr) of the resins 1-4 films increased most during the first day, and varied from 1×1011 ohm for resin 1, to 40 Ω for resin 5 at day 1. The day 1 Rr values of resins 1-4 were inversely proportional to their Hoy's solubility parameter for hydrogen bonding forces. Electrical impedance values of resins 1-3 and 5 varied widely but were relatively constant over time, while those of resin 4 decreased more than 99% from day 1 to 21 (p<0.05). Capacitance (Cr) of films of resins 1-4 all increased over the first day and then were relatively unchanged over the 20 days (except for resin 4 that continued to increase) and were between 0.01 and 1 nF. Silver uptake by TEM revealed the development of water-filled branching structures that formed in resins 4 and 5 over time.

Original languageEnglish (US)
Pages (from-to)3287-3294
Number of pages8
JournalBiomaterials
Volume27
Issue number17
DOIs
StatePublished - Jun 1 2006

Fingerprint

Synthetic Resins
Dielectric Spectroscopy
Electric Impedance
Resins
Water
Acoustic impedance
Solubility
Dental Cements
Spectroscopy
Hydrogen Bonding
Hydrophobic and Hydrophilic Interactions
Silver
Buffers
Electrodes
Transmission electron microscopy
Hydrophilicity
Water absorption

Keywords

  • Dental adhesives
  • Dielectric constant
  • Electrochemistry
  • Hydrophilicity
  • Photopolymerisation

ASJC Scopus subject areas

  • Bioengineering
  • Ceramics and Composites
  • Biophysics
  • Biomaterials
  • Mechanics of Materials

Cite this

Wadgaonkar, B., Ito, S., Svizero, N., Elrod, D., Foulger, S., Rodgers, R., ... Pashley, D. H. (2006). Evaluation of the effect of water-uptake on the impedance of dental resins. Biomaterials, 27(17), 3287-3294. https://doi.org/10.1016/j.biomaterials.2006.01.045

Evaluation of the effect of water-uptake on the impedance of dental resins. / Wadgaonkar, Bakul; Ito, Shuichi; Svizero, Nadia; Elrod, David; Foulger, Stephen; Rodgers, Robert; Oshida, Yoshiki; Kirkland, Kevin; Sword, Jeremy; Rueggeberg, Frederick; Tay, Franklin Chi Meng; Pashley, David Henry.

In: Biomaterials, Vol. 27, No. 17, 01.06.2006, p. 3287-3294.

Research output: Contribution to journalArticle

Wadgaonkar, B, Ito, S, Svizero, N, Elrod, D, Foulger, S, Rodgers, R, Oshida, Y, Kirkland, K, Sword, J, Rueggeberg, F, Tay, FCM & Pashley, DH 2006, 'Evaluation of the effect of water-uptake on the impedance of dental resins', Biomaterials, vol. 27, no. 17, pp. 3287-3294. https://doi.org/10.1016/j.biomaterials.2006.01.045
Wadgaonkar B, Ito S, Svizero N, Elrod D, Foulger S, Rodgers R et al. Evaluation of the effect of water-uptake on the impedance of dental resins. Biomaterials. 2006 Jun 1;27(17):3287-3294. https://doi.org/10.1016/j.biomaterials.2006.01.045
Wadgaonkar, Bakul ; Ito, Shuichi ; Svizero, Nadia ; Elrod, David ; Foulger, Stephen ; Rodgers, Robert ; Oshida, Yoshiki ; Kirkland, Kevin ; Sword, Jeremy ; Rueggeberg, Frederick ; Tay, Franklin Chi Meng ; Pashley, David Henry. / Evaluation of the effect of water-uptake on the impedance of dental resins. In: Biomaterials. 2006 ; Vol. 27, No. 17. pp. 3287-3294.
@article{eac5c1a37e5743618883cd5caab20780,
title = "Evaluation of the effect of water-uptake on the impedance of dental resins",
abstract = "Electrical impedance spectroscopy (EIS) offers a quantitative method of measuring the stability of resin films in aqueous solution over time. Purpose: The purpose of this study was to measure the EIS of five experimental dental adhesive films (ca. 17 μm thick) of increasing hydrophilicity (ranked by their Hoy's solubility parameters), and how much these values change over 3 weeks in aqueous buffer. Methods: The resin films were placed in a U-shaped chamber and a pair of Ag-AgCl electrodes was used for EIS. The EIS results were confirmed by immersing the films in 50{\%} AgNO3 for 24 h to trace the distribution of any water absorption into the resins by TEM observations. Results: The resistance (Rr) of the resins 1-4 films increased most during the first day, and varied from 1×1011 ohm for resin 1, to 40 Ω for resin 5 at day 1. The day 1 Rr values of resins 1-4 were inversely proportional to their Hoy's solubility parameter for hydrogen bonding forces. Electrical impedance values of resins 1-3 and 5 varied widely but were relatively constant over time, while those of resin 4 decreased more than 99{\%} from day 1 to 21 (p<0.05). Capacitance (Cr) of films of resins 1-4 all increased over the first day and then were relatively unchanged over the 20 days (except for resin 4 that continued to increase) and were between 0.01 and 1 nF. Silver uptake by TEM revealed the development of water-filled branching structures that formed in resins 4 and 5 over time.",
keywords = "Dental adhesives, Dielectric constant, Electrochemistry, Hydrophilicity, Photopolymerisation",
author = "Bakul Wadgaonkar and Shuichi Ito and Nadia Svizero and David Elrod and Stephen Foulger and Robert Rodgers and Yoshiki Oshida and Kevin Kirkland and Jeremy Sword and Frederick Rueggeberg and Tay, {Franklin Chi Meng} and Pashley, {David Henry}",
year = "2006",
month = "6",
day = "1",
doi = "10.1016/j.biomaterials.2006.01.045",
language = "English (US)",
volume = "27",
pages = "3287--3294",
journal = "Biomaterials",
issn = "0142-9612",
publisher = "Elsevier BV",
number = "17",

}

TY - JOUR

T1 - Evaluation of the effect of water-uptake on the impedance of dental resins

AU - Wadgaonkar, Bakul

AU - Ito, Shuichi

AU - Svizero, Nadia

AU - Elrod, David

AU - Foulger, Stephen

AU - Rodgers, Robert

AU - Oshida, Yoshiki

AU - Kirkland, Kevin

AU - Sword, Jeremy

AU - Rueggeberg, Frederick

AU - Tay, Franklin Chi Meng

AU - Pashley, David Henry

PY - 2006/6/1

Y1 - 2006/6/1

N2 - Electrical impedance spectroscopy (EIS) offers a quantitative method of measuring the stability of resin films in aqueous solution over time. Purpose: The purpose of this study was to measure the EIS of five experimental dental adhesive films (ca. 17 μm thick) of increasing hydrophilicity (ranked by their Hoy's solubility parameters), and how much these values change over 3 weeks in aqueous buffer. Methods: The resin films were placed in a U-shaped chamber and a pair of Ag-AgCl electrodes was used for EIS. The EIS results were confirmed by immersing the films in 50% AgNO3 for 24 h to trace the distribution of any water absorption into the resins by TEM observations. Results: The resistance (Rr) of the resins 1-4 films increased most during the first day, and varied from 1×1011 ohm for resin 1, to 40 Ω for resin 5 at day 1. The day 1 Rr values of resins 1-4 were inversely proportional to their Hoy's solubility parameter for hydrogen bonding forces. Electrical impedance values of resins 1-3 and 5 varied widely but were relatively constant over time, while those of resin 4 decreased more than 99% from day 1 to 21 (p<0.05). Capacitance (Cr) of films of resins 1-4 all increased over the first day and then were relatively unchanged over the 20 days (except for resin 4 that continued to increase) and were between 0.01 and 1 nF. Silver uptake by TEM revealed the development of water-filled branching structures that formed in resins 4 and 5 over time.

AB - Electrical impedance spectroscopy (EIS) offers a quantitative method of measuring the stability of resin films in aqueous solution over time. Purpose: The purpose of this study was to measure the EIS of five experimental dental adhesive films (ca. 17 μm thick) of increasing hydrophilicity (ranked by their Hoy's solubility parameters), and how much these values change over 3 weeks in aqueous buffer. Methods: The resin films were placed in a U-shaped chamber and a pair of Ag-AgCl electrodes was used for EIS. The EIS results were confirmed by immersing the films in 50% AgNO3 for 24 h to trace the distribution of any water absorption into the resins by TEM observations. Results: The resistance (Rr) of the resins 1-4 films increased most during the first day, and varied from 1×1011 ohm for resin 1, to 40 Ω for resin 5 at day 1. The day 1 Rr values of resins 1-4 were inversely proportional to their Hoy's solubility parameter for hydrogen bonding forces. Electrical impedance values of resins 1-3 and 5 varied widely but were relatively constant over time, while those of resin 4 decreased more than 99% from day 1 to 21 (p<0.05). Capacitance (Cr) of films of resins 1-4 all increased over the first day and then were relatively unchanged over the 20 days (except for resin 4 that continued to increase) and were between 0.01 and 1 nF. Silver uptake by TEM revealed the development of water-filled branching structures that formed in resins 4 and 5 over time.

KW - Dental adhesives

KW - Dielectric constant

KW - Electrochemistry

KW - Hydrophilicity

KW - Photopolymerisation

UR - http://www.scopus.com/inward/record.url?scp=33644759307&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33644759307&partnerID=8YFLogxK

U2 - 10.1016/j.biomaterials.2006.01.045

DO - 10.1016/j.biomaterials.2006.01.045

M3 - Article

VL - 27

SP - 3287

EP - 3294

JO - Biomaterials

JF - Biomaterials

SN - 0142-9612

IS - 17

ER -