Exposure-response modeling of flow-mediated dilation provides an unbiased and informative measure of endothelial function

Charles H. Van Brackle, Ryan A. Harris, K. Melissa Hallow

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The brachial artery flow-mediated dilation (FMD) test is the most widely utilized method to evaluate endothelial function noninvasively in humans by calculating the percent change in diameter (FMD%). However, the underutilized velocity and diameter time course data, coupled with confounding influences in shear exposure, noise, and upward bias, make the FMD test less desirable. In this study, we developed an exposure-response, model-based approach that not only quantifies FMD based on the rich velocity and diameter data, it overcomes previously acknowledged challenges. FMD data were obtained from 15 apparently healthy participants, each exposed to four different cuff occlusion durations. The velocity response following cuff release was described by an exponential model with two parameters defining peak velocity and rate of decay. Shear exposure derived from velocity was used to drive the diameter response model, which consists of additive constriction and dilation terms. Three parameters describing distinct aspects of the vascular response to shear (magnitude of the initial constriction response, and magnitude and time constant of the dilation response) were estimated for both the individuals and population. These parameters are independent of shear exposure. Thus this approach produces identifiable and physiologically meaningful parameters that may provide additional information for comparing differences between experimental groups or over time, and provides a means to completely account for shear exposure.

Original languageEnglish (US)
Pages (from-to)1292-1303
Number of pages12
JournalJournal of Applied Physiology
Volume122
Issue number5
DOIs
StatePublished - May 2017

Fingerprint

Dilatation
Constriction
Brachial Artery
Statistical Models
Blood Vessels
Noise
Healthy Volunteers
Population

Keywords

  • Endothelial function
  • Exposure-response model
  • Flow-mediated dilation
  • Reactive hyperemia

ASJC Scopus subject areas

  • Physiology
  • Physiology (medical)

Cite this

Exposure-response modeling of flow-mediated dilation provides an unbiased and informative measure of endothelial function. / Van Brackle, Charles H.; Harris, Ryan A.; Hallow, K. Melissa.

In: Journal of Applied Physiology, Vol. 122, No. 5, 05.2017, p. 1292-1303.

Research output: Contribution to journalArticle

@article{14bfb3eda4074338b1b65ca039a7165a,
title = "Exposure-response modeling of flow-mediated dilation provides an unbiased and informative measure of endothelial function",
abstract = "The brachial artery flow-mediated dilation (FMD) test is the most widely utilized method to evaluate endothelial function noninvasively in humans by calculating the percent change in diameter (FMD{\%}). However, the underutilized velocity and diameter time course data, coupled with confounding influences in shear exposure, noise, and upward bias, make the FMD test less desirable. In this study, we developed an exposure-response, model-based approach that not only quantifies FMD based on the rich velocity and diameter data, it overcomes previously acknowledged challenges. FMD data were obtained from 15 apparently healthy participants, each exposed to four different cuff occlusion durations. The velocity response following cuff release was described by an exponential model with two parameters defining peak velocity and rate of decay. Shear exposure derived from velocity was used to drive the diameter response model, which consists of additive constriction and dilation terms. Three parameters describing distinct aspects of the vascular response to shear (magnitude of the initial constriction response, and magnitude and time constant of the dilation response) were estimated for both the individuals and population. These parameters are independent of shear exposure. Thus this approach produces identifiable and physiologically meaningful parameters that may provide additional information for comparing differences between experimental groups or over time, and provides a means to completely account for shear exposure.",
keywords = "Endothelial function, Exposure-response model, Flow-mediated dilation, Reactive hyperemia",
author = "{Van Brackle}, {Charles H.} and Harris, {Ryan A.} and Hallow, {K. Melissa}",
year = "2017",
month = "5",
doi = "10.1152/japplphysiol.00734.2016",
language = "English (US)",
volume = "122",
pages = "1292--1303",
journal = "Journal of Applied Physiology Respiratory Environmental and Exercise Physiology",
issn = "8750-7587",
publisher = "American Physiological Society",
number = "5",

}

TY - JOUR

T1 - Exposure-response modeling of flow-mediated dilation provides an unbiased and informative measure of endothelial function

AU - Van Brackle, Charles H.

AU - Harris, Ryan A.

AU - Hallow, K. Melissa

PY - 2017/5

Y1 - 2017/5

N2 - The brachial artery flow-mediated dilation (FMD) test is the most widely utilized method to evaluate endothelial function noninvasively in humans by calculating the percent change in diameter (FMD%). However, the underutilized velocity and diameter time course data, coupled with confounding influences in shear exposure, noise, and upward bias, make the FMD test less desirable. In this study, we developed an exposure-response, model-based approach that not only quantifies FMD based on the rich velocity and diameter data, it overcomes previously acknowledged challenges. FMD data were obtained from 15 apparently healthy participants, each exposed to four different cuff occlusion durations. The velocity response following cuff release was described by an exponential model with two parameters defining peak velocity and rate of decay. Shear exposure derived from velocity was used to drive the diameter response model, which consists of additive constriction and dilation terms. Three parameters describing distinct aspects of the vascular response to shear (magnitude of the initial constriction response, and magnitude and time constant of the dilation response) were estimated for both the individuals and population. These parameters are independent of shear exposure. Thus this approach produces identifiable and physiologically meaningful parameters that may provide additional information for comparing differences between experimental groups or over time, and provides a means to completely account for shear exposure.

AB - The brachial artery flow-mediated dilation (FMD) test is the most widely utilized method to evaluate endothelial function noninvasively in humans by calculating the percent change in diameter (FMD%). However, the underutilized velocity and diameter time course data, coupled with confounding influences in shear exposure, noise, and upward bias, make the FMD test less desirable. In this study, we developed an exposure-response, model-based approach that not only quantifies FMD based on the rich velocity and diameter data, it overcomes previously acknowledged challenges. FMD data were obtained from 15 apparently healthy participants, each exposed to four different cuff occlusion durations. The velocity response following cuff release was described by an exponential model with two parameters defining peak velocity and rate of decay. Shear exposure derived from velocity was used to drive the diameter response model, which consists of additive constriction and dilation terms. Three parameters describing distinct aspects of the vascular response to shear (magnitude of the initial constriction response, and magnitude and time constant of the dilation response) were estimated for both the individuals and population. These parameters are independent of shear exposure. Thus this approach produces identifiable and physiologically meaningful parameters that may provide additional information for comparing differences between experimental groups or over time, and provides a means to completely account for shear exposure.

KW - Endothelial function

KW - Exposure-response model

KW - Flow-mediated dilation

KW - Reactive hyperemia

UR - http://www.scopus.com/inward/record.url?scp=85035073023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85035073023&partnerID=8YFLogxK

U2 - 10.1152/japplphysiol.00734.2016

DO - 10.1152/japplphysiol.00734.2016

M3 - Article

C2 - 27979986

AN - SCOPUS:85035073023

VL - 122

SP - 1292

EP - 1303

JO - Journal of Applied Physiology Respiratory Environmental and Exercise Physiology

JF - Journal of Applied Physiology Respiratory Environmental and Exercise Physiology

SN - 8750-7587

IS - 5

ER -