Initial Experience with Elective Perventricular Melody Valve Placement in Small Patients

Aamisha Gupta, Damien Kenny, Massimo Caputo, Zahid Amin

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Perventricular Melody valve placement has been described as a bailout approach or alternative RVOT approach in patients >30 kg. We present three patients <20 kg and two patients with limited venous access, where we electively performed the perventricular approach. Retrospective analysis of patients <30 kg and vascular access limitation undergoing elective hybrid pulmonary valve replacement were reviewed. The subcostal approach was performed without sternotomy with the sheath introduced through the diaphragmatic surface of the right ventricle. Diagnoses included tetralogy of Fallot (n = 3) and truncus arteriosus (n = 2). Mean weight was 16.2 kg (range 4.7–28.1 kg). Four patients had RV–PA conduits (size: 14–21 mm), and the fifth patient had a transannular patch. All patients met criteria for surgical valve replacement. Technical success was 100%. In two patients with absent pulmonary valve, the stent migrated during advancement of the delivery sheath. These stents were anchored in the distal main pulmonary artery (n = 1) or branch pulmonary artery (n = 1) without sequela. Tricuspid valve chordal injury occurred in one patient, where transesophageal echocardiogram (TEE) was not utilized. No patient required conversion to cardiopulmonary bypass. One patient with absent pulmonary valve died on follow-up as a consequence of severe airway compromise. Our initial experience demonstrates that the perventricular valve can be placed safely in small-sized patients. Advancement of the melody ensemble may be difficult and may cause stent migration. We conclude that the technique is feasible in small-sized patients and that prevention of complications includes placement of the stent at the time of the valve and TEE assistance in reducing tricuspid valve injury.

Original languageEnglish (US)
Pages (from-to)575-581
Number of pages7
JournalPediatric Cardiology
Volume38
Issue number3
DOIs
StatePublished - Mar 1 2017

Fingerprint

Pulmonary Valve
Stents
Tricuspid Valve
Pulmonary Artery
Truncus Arteriosus
Sternotomy
Tetralogy of Fallot
Wounds and Injuries
Cardiopulmonary Bypass
Surgical Instruments
Heart Ventricles
Blood Vessels
Weights and Measures

Keywords

  • Congenital
  • Hybrid
  • Pulmonary valve

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Cardiology and Cardiovascular Medicine

Cite this

Initial Experience with Elective Perventricular Melody Valve Placement in Small Patients. / Gupta, Aamisha; Kenny, Damien; Caputo, Massimo; Amin, Zahid.

In: Pediatric Cardiology, Vol. 38, No. 3, 01.03.2017, p. 575-581.

Research output: Contribution to journalArticle

Gupta, Aamisha ; Kenny, Damien ; Caputo, Massimo ; Amin, Zahid. / Initial Experience with Elective Perventricular Melody Valve Placement in Small Patients. In: Pediatric Cardiology. 2017 ; Vol. 38, No. 3. pp. 575-581.
@article{4832ea01925f4cdb95dc50199a3ae054,
title = "Initial Experience with Elective Perventricular Melody Valve Placement in Small Patients",
abstract = "Perventricular Melody valve placement has been described as a bailout approach or alternative RVOT approach in patients >30 kg. We present three patients <20 kg and two patients with limited venous access, where we electively performed the perventricular approach. Retrospective analysis of patients <30 kg and vascular access limitation undergoing elective hybrid pulmonary valve replacement were reviewed. The subcostal approach was performed without sternotomy with the sheath introduced through the diaphragmatic surface of the right ventricle. Diagnoses included tetralogy of Fallot (n = 3) and truncus arteriosus (n = 2). Mean weight was 16.2 kg (range 4.7–28.1 kg). Four patients had RV–PA conduits (size: 14–21 mm), and the fifth patient had a transannular patch. All patients met criteria for surgical valve replacement. Technical success was 100{\%}. In two patients with absent pulmonary valve, the stent migrated during advancement of the delivery sheath. These stents were anchored in the distal main pulmonary artery (n = 1) or branch pulmonary artery (n = 1) without sequela. Tricuspid valve chordal injury occurred in one patient, where transesophageal echocardiogram (TEE) was not utilized. No patient required conversion to cardiopulmonary bypass. One patient with absent pulmonary valve died on follow-up as a consequence of severe airway compromise. Our initial experience demonstrates that the perventricular valve can be placed safely in small-sized patients. Advancement of the melody ensemble may be difficult and may cause stent migration. We conclude that the technique is feasible in small-sized patients and that prevention of complications includes placement of the stent at the time of the valve and TEE assistance in reducing tricuspid valve injury.",
keywords = "Congenital, Hybrid, Pulmonary valve",
author = "Aamisha Gupta and Damien Kenny and Massimo Caputo and Zahid Amin",
year = "2017",
month = "3",
day = "1",
doi = "10.1007/s00246-016-1550-0",
language = "English (US)",
volume = "38",
pages = "575--581",
journal = "Pediatric Cardiology",
issn = "0172-0643",
publisher = "Springer New York",
number = "3",

}

TY - JOUR

T1 - Initial Experience with Elective Perventricular Melody Valve Placement in Small Patients

AU - Gupta, Aamisha

AU - Kenny, Damien

AU - Caputo, Massimo

AU - Amin, Zahid

PY - 2017/3/1

Y1 - 2017/3/1

N2 - Perventricular Melody valve placement has been described as a bailout approach or alternative RVOT approach in patients >30 kg. We present three patients <20 kg and two patients with limited venous access, where we electively performed the perventricular approach. Retrospective analysis of patients <30 kg and vascular access limitation undergoing elective hybrid pulmonary valve replacement were reviewed. The subcostal approach was performed without sternotomy with the sheath introduced through the diaphragmatic surface of the right ventricle. Diagnoses included tetralogy of Fallot (n = 3) and truncus arteriosus (n = 2). Mean weight was 16.2 kg (range 4.7–28.1 kg). Four patients had RV–PA conduits (size: 14–21 mm), and the fifth patient had a transannular patch. All patients met criteria for surgical valve replacement. Technical success was 100%. In two patients with absent pulmonary valve, the stent migrated during advancement of the delivery sheath. These stents were anchored in the distal main pulmonary artery (n = 1) or branch pulmonary artery (n = 1) without sequela. Tricuspid valve chordal injury occurred in one patient, where transesophageal echocardiogram (TEE) was not utilized. No patient required conversion to cardiopulmonary bypass. One patient with absent pulmonary valve died on follow-up as a consequence of severe airway compromise. Our initial experience demonstrates that the perventricular valve can be placed safely in small-sized patients. Advancement of the melody ensemble may be difficult and may cause stent migration. We conclude that the technique is feasible in small-sized patients and that prevention of complications includes placement of the stent at the time of the valve and TEE assistance in reducing tricuspid valve injury.

AB - Perventricular Melody valve placement has been described as a bailout approach or alternative RVOT approach in patients >30 kg. We present three patients <20 kg and two patients with limited venous access, where we electively performed the perventricular approach. Retrospective analysis of patients <30 kg and vascular access limitation undergoing elective hybrid pulmonary valve replacement were reviewed. The subcostal approach was performed without sternotomy with the sheath introduced through the diaphragmatic surface of the right ventricle. Diagnoses included tetralogy of Fallot (n = 3) and truncus arteriosus (n = 2). Mean weight was 16.2 kg (range 4.7–28.1 kg). Four patients had RV–PA conduits (size: 14–21 mm), and the fifth patient had a transannular patch. All patients met criteria for surgical valve replacement. Technical success was 100%. In two patients with absent pulmonary valve, the stent migrated during advancement of the delivery sheath. These stents were anchored in the distal main pulmonary artery (n = 1) or branch pulmonary artery (n = 1) without sequela. Tricuspid valve chordal injury occurred in one patient, where transesophageal echocardiogram (TEE) was not utilized. No patient required conversion to cardiopulmonary bypass. One patient with absent pulmonary valve died on follow-up as a consequence of severe airway compromise. Our initial experience demonstrates that the perventricular valve can be placed safely in small-sized patients. Advancement of the melody ensemble may be difficult and may cause stent migration. We conclude that the technique is feasible in small-sized patients and that prevention of complications includes placement of the stent at the time of the valve and TEE assistance in reducing tricuspid valve injury.

KW - Congenital

KW - Hybrid

KW - Pulmonary valve

UR - http://www.scopus.com/inward/record.url?scp=85006414940&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85006414940&partnerID=8YFLogxK

U2 - 10.1007/s00246-016-1550-0

DO - 10.1007/s00246-016-1550-0

M3 - Article

VL - 38

SP - 575

EP - 581

JO - Pediatric Cardiology

JF - Pediatric Cardiology

SN - 0172-0643

IS - 3

ER -