Laparoscopic Application of Interceed (TC7) in the Pig

Michael Peter Diamond, Tim Cunningham, Cary B. Linsky, Alan H. DeCherney

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Interceed (TC7) is an absorbable barrier that has been shown to be efficacious in reducing postoperative adhesions in animal models and in a human clinical trial. In these studies, Interceed (TC7) was applied at the time of laparotomy. However, increasingly more operative procedures are being performed at laparoscopy. Because of the concern that postoperative adhesion development would limit pregnancy outcome following these laparoscopic procedures, we evaluated the possibility of placement of Interceed (TC7) laparoscopically. Trials were conducted in anesthetized pigs using a three-puncture approach. Small pieces (<1 × 2 cm) of Interceed (TC7) were able to be pushed through a 5 mm second puncture probe, although larger pieces could not be introduced in this fashion. Larger pieces (up to 5 × 7 cm) were introduced as follows. The operating laparoscope was removed from the trocar, a grasping instrument was placed through the operating channel, the material was grasped, the Interceed (TC7) was drawn into the operating channel of the laparoscope, the laparoscope was reintroduced into the abdominal cavity, and the grasping probe was extended through the operating channel. The Interceed (TC7) could then be grasped by instruments introduced through the second puncture sheaths. The material was manipulated to cover parietal and visceral peritoneal surfaces. Once in place, the material was moistened, and it remained in place without suturing. We conclude that it is feasible to consider clinical application of Interceed (TC7) as a part of operative laparoscopic procedures.

Original languageEnglish (US)
Pages (from-to)145-148
Number of pages4
JournalJournal of Gynecologic Surgery
Volume5
Issue number2
DOIs
StatePublished - Jan 1 1989
Externally publishedYes

Fingerprint

Swine
Laparoscopes
Punctures
Operative Surgical Procedures
Abdominal Cavity
Pregnancy Outcome
INTERCEED
Surgical Instruments
Laparoscopy
Laparotomy
Animal Models
Clinical Trials

ASJC Scopus subject areas

  • Surgery
  • Obstetrics and Gynecology

Cite this

Laparoscopic Application of Interceed (TC7) in the Pig. / Diamond, Michael Peter; Cunningham, Tim; Linsky, Cary B.; DeCherney, Alan H.

In: Journal of Gynecologic Surgery, Vol. 5, No. 2, 01.01.1989, p. 145-148.

Research output: Contribution to journalArticle

Diamond, Michael Peter ; Cunningham, Tim ; Linsky, Cary B. ; DeCherney, Alan H. / Laparoscopic Application of Interceed (TC7) in the Pig. In: Journal of Gynecologic Surgery. 1989 ; Vol. 5, No. 2. pp. 145-148.
@article{fcb981033788475b89ab1d3f3c076099,
title = "Laparoscopic Application of Interceed (TC7) in the Pig",
abstract = "Interceed (TC7) is an absorbable barrier that has been shown to be efficacious in reducing postoperative adhesions in animal models and in a human clinical trial. In these studies, Interceed (TC7) was applied at the time of laparotomy. However, increasingly more operative procedures are being performed at laparoscopy. Because of the concern that postoperative adhesion development would limit pregnancy outcome following these laparoscopic procedures, we evaluated the possibility of placement of Interceed (TC7) laparoscopically. Trials were conducted in anesthetized pigs using a three-puncture approach. Small pieces (<1 × 2 cm) of Interceed (TC7) were able to be pushed through a 5 mm second puncture probe, although larger pieces could not be introduced in this fashion. Larger pieces (up to 5 × 7 cm) were introduced as follows. The operating laparoscope was removed from the trocar, a grasping instrument was placed through the operating channel, the material was grasped, the Interceed (TC7) was drawn into the operating channel of the laparoscope, the laparoscope was reintroduced into the abdominal cavity, and the grasping probe was extended through the operating channel. The Interceed (TC7) could then be grasped by instruments introduced through the second puncture sheaths. The material was manipulated to cover parietal and visceral peritoneal surfaces. Once in place, the material was moistened, and it remained in place without suturing. We conclude that it is feasible to consider clinical application of Interceed (TC7) as a part of operative laparoscopic procedures.",
author = "Diamond, {Michael Peter} and Tim Cunningham and Linsky, {Cary B.} and DeCherney, {Alan H.}",
year = "1989",
month = "1",
day = "1",
doi = "10.1089/gyn.1989.5.145",
language = "English (US)",
volume = "5",
pages = "145--148",
journal = "Journal of Gynecologic Surgery",
issn = "1042-4067",
publisher = "Mary Ann Liebert Inc.",
number = "2",

}

TY - JOUR

T1 - Laparoscopic Application of Interceed (TC7) in the Pig

AU - Diamond, Michael Peter

AU - Cunningham, Tim

AU - Linsky, Cary B.

AU - DeCherney, Alan H.

PY - 1989/1/1

Y1 - 1989/1/1

N2 - Interceed (TC7) is an absorbable barrier that has been shown to be efficacious in reducing postoperative adhesions in animal models and in a human clinical trial. In these studies, Interceed (TC7) was applied at the time of laparotomy. However, increasingly more operative procedures are being performed at laparoscopy. Because of the concern that postoperative adhesion development would limit pregnancy outcome following these laparoscopic procedures, we evaluated the possibility of placement of Interceed (TC7) laparoscopically. Trials were conducted in anesthetized pigs using a three-puncture approach. Small pieces (<1 × 2 cm) of Interceed (TC7) were able to be pushed through a 5 mm second puncture probe, although larger pieces could not be introduced in this fashion. Larger pieces (up to 5 × 7 cm) were introduced as follows. The operating laparoscope was removed from the trocar, a grasping instrument was placed through the operating channel, the material was grasped, the Interceed (TC7) was drawn into the operating channel of the laparoscope, the laparoscope was reintroduced into the abdominal cavity, and the grasping probe was extended through the operating channel. The Interceed (TC7) could then be grasped by instruments introduced through the second puncture sheaths. The material was manipulated to cover parietal and visceral peritoneal surfaces. Once in place, the material was moistened, and it remained in place without suturing. We conclude that it is feasible to consider clinical application of Interceed (TC7) as a part of operative laparoscopic procedures.

AB - Interceed (TC7) is an absorbable barrier that has been shown to be efficacious in reducing postoperative adhesions in animal models and in a human clinical trial. In these studies, Interceed (TC7) was applied at the time of laparotomy. However, increasingly more operative procedures are being performed at laparoscopy. Because of the concern that postoperative adhesion development would limit pregnancy outcome following these laparoscopic procedures, we evaluated the possibility of placement of Interceed (TC7) laparoscopically. Trials were conducted in anesthetized pigs using a three-puncture approach. Small pieces (<1 × 2 cm) of Interceed (TC7) were able to be pushed through a 5 mm second puncture probe, although larger pieces could not be introduced in this fashion. Larger pieces (up to 5 × 7 cm) were introduced as follows. The operating laparoscope was removed from the trocar, a grasping instrument was placed through the operating channel, the material was grasped, the Interceed (TC7) was drawn into the operating channel of the laparoscope, the laparoscope was reintroduced into the abdominal cavity, and the grasping probe was extended through the operating channel. The Interceed (TC7) could then be grasped by instruments introduced through the second puncture sheaths. The material was manipulated to cover parietal and visceral peritoneal surfaces. Once in place, the material was moistened, and it remained in place without suturing. We conclude that it is feasible to consider clinical application of Interceed (TC7) as a part of operative laparoscopic procedures.

UR - http://www.scopus.com/inward/record.url?scp=0024427701&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024427701&partnerID=8YFLogxK

U2 - 10.1089/gyn.1989.5.145

DO - 10.1089/gyn.1989.5.145

M3 - Article

VL - 5

SP - 145

EP - 148

JO - Journal of Gynecologic Surgery

JF - Journal of Gynecologic Surgery

SN - 1042-4067

IS - 2

ER -