Localization of fossa ovalis and Brockenbrough needle prior to left atrial ablation using three-dimensional mapping with EnSite Fusion™

Sumit Verma, Stuart Adler, Adam Eric Berman, Aurillo Duran, Diane Loar

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Background: Transseptal catheterization of the interatrial septum has traditionally been performed under the guidance of fluoroscopy, echocardiography, and hemodynamic pressure monitoring. We hypothesized that the fossa ovalis could be identified on pre-ablation chest computerized tomography (CT) scan utilizing EnSite Verismo™ and Fusion™ software thereby permitting its real-time visualization during transseptal puncture. Objective: The purpose of this study is to generate multi-center data demonstrating the feasibility of the identification of the fossa ovalis and visualization of the transseptal needle tip using EnSite Verismo™ segmentation and EnSite Fusion™ prior to transseptal puncture. Methods: Patients scheduled to undergo transseptal puncture for ablation were enrolled. Pre-ablation CT scans were performed in all patients. The Verismo™ software tool was used to import and segmentally manipulate a three-dimensional CT image on the EnSite™ system workstation. EnSite Fusion™ registration was used to register the right atrial image and label and confirm the fossa ovalis' location prior to transseptal puncture. Results: Analysis of the pre-ablation CT scan using EnSite Fusion™ successfully allowed assessment of the anatomy and location of the fossa ovalis. Additionally, the transseptal needle tip location was located within the CT scan designated fossa ovalis location in 96% of cases. Conclusion: It is possible to visualize the fossa ovalis on pre-ablation CT and localize the transseptal needle accurately within the margins of the fossa ovalis utilizing EnSite Fusion™ and Verismo™ software.

Original languageEnglish (US)
Pages (from-to)37-44
Number of pages8
JournalJournal of Interventional Cardiac Electrophysiology
Volume30
Issue number1
DOIs
StatePublished - Jan 1 2011

Fingerprint

Needles
Tomography
Punctures
Software
Fluoroscopy
Catheterization
Echocardiography
Anatomy
Thorax
Hemodynamics
Pressure

Keywords

  • 3D mapping
  • Cardiac CT
  • Cardiac anatomy
  • Cardiac imaging
  • Transseptal puncture

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Localization of fossa ovalis and Brockenbrough needle prior to left atrial ablation using three-dimensional mapping with EnSite Fusion™. / Verma, Sumit; Adler, Stuart; Berman, Adam Eric; Duran, Aurillo; Loar, Diane.

In: Journal of Interventional Cardiac Electrophysiology, Vol. 30, No. 1, 01.01.2011, p. 37-44.

Research output: Contribution to journalArticle

@article{cf9eb5208ca14becaa6bb31cdbe76d6a,
title = "Localization of fossa ovalis and Brockenbrough needle prior to left atrial ablation using three-dimensional mapping with EnSite Fusion™",
abstract = "Background: Transseptal catheterization of the interatrial septum has traditionally been performed under the guidance of fluoroscopy, echocardiography, and hemodynamic pressure monitoring. We hypothesized that the fossa ovalis could be identified on pre-ablation chest computerized tomography (CT) scan utilizing EnSite Verismo™ and Fusion™ software thereby permitting its real-time visualization during transseptal puncture. Objective: The purpose of this study is to generate multi-center data demonstrating the feasibility of the identification of the fossa ovalis and visualization of the transseptal needle tip using EnSite Verismo™ segmentation and EnSite Fusion™ prior to transseptal puncture. Methods: Patients scheduled to undergo transseptal puncture for ablation were enrolled. Pre-ablation CT scans were performed in all patients. The Verismo™ software tool was used to import and segmentally manipulate a three-dimensional CT image on the EnSite™ system workstation. EnSite Fusion™ registration was used to register the right atrial image and label and confirm the fossa ovalis' location prior to transseptal puncture. Results: Analysis of the pre-ablation CT scan using EnSite Fusion™ successfully allowed assessment of the anatomy and location of the fossa ovalis. Additionally, the transseptal needle tip location was located within the CT scan designated fossa ovalis location in 96{\%} of cases. Conclusion: It is possible to visualize the fossa ovalis on pre-ablation CT and localize the transseptal needle accurately within the margins of the fossa ovalis utilizing EnSite Fusion™ and Verismo™ software.",
keywords = "3D mapping, Cardiac CT, Cardiac anatomy, Cardiac imaging, Transseptal puncture",
author = "Sumit Verma and Stuart Adler and Berman, {Adam Eric} and Aurillo Duran and Diane Loar",
year = "2011",
month = "1",
day = "1",
doi = "10.1007/s10840-010-9525-1",
language = "English (US)",
volume = "30",
pages = "37--44",
journal = "Journal of Interventional Cardiac Electrophysiology",
issn = "1383-875X",
publisher = "Springer Netherlands",
number = "1",

}

TY - JOUR

T1 - Localization of fossa ovalis and Brockenbrough needle prior to left atrial ablation using three-dimensional mapping with EnSite Fusion™

AU - Verma, Sumit

AU - Adler, Stuart

AU - Berman, Adam Eric

AU - Duran, Aurillo

AU - Loar, Diane

PY - 2011/1/1

Y1 - 2011/1/1

N2 - Background: Transseptal catheterization of the interatrial septum has traditionally been performed under the guidance of fluoroscopy, echocardiography, and hemodynamic pressure monitoring. We hypothesized that the fossa ovalis could be identified on pre-ablation chest computerized tomography (CT) scan utilizing EnSite Verismo™ and Fusion™ software thereby permitting its real-time visualization during transseptal puncture. Objective: The purpose of this study is to generate multi-center data demonstrating the feasibility of the identification of the fossa ovalis and visualization of the transseptal needle tip using EnSite Verismo™ segmentation and EnSite Fusion™ prior to transseptal puncture. Methods: Patients scheduled to undergo transseptal puncture for ablation were enrolled. Pre-ablation CT scans were performed in all patients. The Verismo™ software tool was used to import and segmentally manipulate a three-dimensional CT image on the EnSite™ system workstation. EnSite Fusion™ registration was used to register the right atrial image and label and confirm the fossa ovalis' location prior to transseptal puncture. Results: Analysis of the pre-ablation CT scan using EnSite Fusion™ successfully allowed assessment of the anatomy and location of the fossa ovalis. Additionally, the transseptal needle tip location was located within the CT scan designated fossa ovalis location in 96% of cases. Conclusion: It is possible to visualize the fossa ovalis on pre-ablation CT and localize the transseptal needle accurately within the margins of the fossa ovalis utilizing EnSite Fusion™ and Verismo™ software.

AB - Background: Transseptal catheterization of the interatrial septum has traditionally been performed under the guidance of fluoroscopy, echocardiography, and hemodynamic pressure monitoring. We hypothesized that the fossa ovalis could be identified on pre-ablation chest computerized tomography (CT) scan utilizing EnSite Verismo™ and Fusion™ software thereby permitting its real-time visualization during transseptal puncture. Objective: The purpose of this study is to generate multi-center data demonstrating the feasibility of the identification of the fossa ovalis and visualization of the transseptal needle tip using EnSite Verismo™ segmentation and EnSite Fusion™ prior to transseptal puncture. Methods: Patients scheduled to undergo transseptal puncture for ablation were enrolled. Pre-ablation CT scans were performed in all patients. The Verismo™ software tool was used to import and segmentally manipulate a three-dimensional CT image on the EnSite™ system workstation. EnSite Fusion™ registration was used to register the right atrial image and label and confirm the fossa ovalis' location prior to transseptal puncture. Results: Analysis of the pre-ablation CT scan using EnSite Fusion™ successfully allowed assessment of the anatomy and location of the fossa ovalis. Additionally, the transseptal needle tip location was located within the CT scan designated fossa ovalis location in 96% of cases. Conclusion: It is possible to visualize the fossa ovalis on pre-ablation CT and localize the transseptal needle accurately within the margins of the fossa ovalis utilizing EnSite Fusion™ and Verismo™ software.

KW - 3D mapping

KW - Cardiac CT

KW - Cardiac anatomy

KW - Cardiac imaging

KW - Transseptal puncture

UR - http://www.scopus.com/inward/record.url?scp=79952005231&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79952005231&partnerID=8YFLogxK

U2 - 10.1007/s10840-010-9525-1

DO - 10.1007/s10840-010-9525-1

M3 - Article

C2 - 21153915

AN - SCOPUS:79952005231

VL - 30

SP - 37

EP - 44

JO - Journal of Interventional Cardiac Electrophysiology

JF - Journal of Interventional Cardiac Electrophysiology

SN - 1383-875X

IS - 1

ER -