M-mode ultrasound for the detection of pneumothorax during helicopter transport

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Background: The presence of the sonographic sliding lung sign (SLS) is a sensitive indicator for the absence of a pneumothorax. The addition of M-mode ultrasound (US) can be a useful adjunct in detecting the SLS. Objective: The objective of this study is to determine the feasibility of using M-mode US in evaluating the SLS during helicopter transport. Methods: A model simulating human lung was used during image acquisition. M-mode images of the SLS were obtained during 3 distinct phases of transport: without rotor rotation, with rotor rotation while on the ground, and at level flight. Four US-credentialed emergency physicians evaluated M-mode US tracings of the model along with examples from human lungs, both with and without pneumothorax, in random fashion. Results: A total of 104 images were reviewed (26 images per reviewer). All of the M-mode images were correctly identified. Motion artifact was noted on the M-mode tracings taken during rotor rotation, which was greatest during level flight. The rotor artifact was not felt to affect the diagnostic utility of the M-mode US tracing. Conclusion: M-mode US may be used successfully to detect the SLS during helicopter transport.

Original languageEnglish (US)
Pages (from-to)1577-1580
Number of pages4
JournalAmerican Journal of Emergency Medicine
Volume30
Issue number8
DOIs
StatePublished - Jan 1 2012

Fingerprint

Aircraft
Pneumothorax
Lung
Artifacts
Emergencies
Physicians

ASJC Scopus subject areas

  • Emergency Medicine

Cite this

M-mode ultrasound for the detection of pneumothorax during helicopter transport. / Lyon, Matthew L; Shiver, Stephen A; Walton, Perry.

In: American Journal of Emergency Medicine, Vol. 30, No. 8, 01.01.2012, p. 1577-1580.

Research output: Contribution to journalArticle

@article{6beaaa47123640c1be5074723a46dc5f,
title = "M-mode ultrasound for the detection of pneumothorax during helicopter transport",
abstract = "Background: The presence of the sonographic sliding lung sign (SLS) is a sensitive indicator for the absence of a pneumothorax. The addition of M-mode ultrasound (US) can be a useful adjunct in detecting the SLS. Objective: The objective of this study is to determine the feasibility of using M-mode US in evaluating the SLS during helicopter transport. Methods: A model simulating human lung was used during image acquisition. M-mode images of the SLS were obtained during 3 distinct phases of transport: without rotor rotation, with rotor rotation while on the ground, and at level flight. Four US-credentialed emergency physicians evaluated M-mode US tracings of the model along with examples from human lungs, both with and without pneumothorax, in random fashion. Results: A total of 104 images were reviewed (26 images per reviewer). All of the M-mode images were correctly identified. Motion artifact was noted on the M-mode tracings taken during rotor rotation, which was greatest during level flight. The rotor artifact was not felt to affect the diagnostic utility of the M-mode US tracing. Conclusion: M-mode US may be used successfully to detect the SLS during helicopter transport.",
author = "Lyon, {Matthew L} and Shiver, {Stephen A} and Perry Walton",
year = "2012",
month = "1",
day = "1",
doi = "10.1016/j.ajem.2011.08.022",
language = "English (US)",
volume = "30",
pages = "1577--1580",
journal = "American Journal of Emergency Medicine",
issn = "0735-6757",
publisher = "W.B. Saunders Ltd",
number = "8",

}

TY - JOUR

T1 - M-mode ultrasound for the detection of pneumothorax during helicopter transport

AU - Lyon, Matthew L

AU - Shiver, Stephen A

AU - Walton, Perry

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Background: The presence of the sonographic sliding lung sign (SLS) is a sensitive indicator for the absence of a pneumothorax. The addition of M-mode ultrasound (US) can be a useful adjunct in detecting the SLS. Objective: The objective of this study is to determine the feasibility of using M-mode US in evaluating the SLS during helicopter transport. Methods: A model simulating human lung was used during image acquisition. M-mode images of the SLS were obtained during 3 distinct phases of transport: without rotor rotation, with rotor rotation while on the ground, and at level flight. Four US-credentialed emergency physicians evaluated M-mode US tracings of the model along with examples from human lungs, both with and without pneumothorax, in random fashion. Results: A total of 104 images were reviewed (26 images per reviewer). All of the M-mode images were correctly identified. Motion artifact was noted on the M-mode tracings taken during rotor rotation, which was greatest during level flight. The rotor artifact was not felt to affect the diagnostic utility of the M-mode US tracing. Conclusion: M-mode US may be used successfully to detect the SLS during helicopter transport.

AB - Background: The presence of the sonographic sliding lung sign (SLS) is a sensitive indicator for the absence of a pneumothorax. The addition of M-mode ultrasound (US) can be a useful adjunct in detecting the SLS. Objective: The objective of this study is to determine the feasibility of using M-mode US in evaluating the SLS during helicopter transport. Methods: A model simulating human lung was used during image acquisition. M-mode images of the SLS were obtained during 3 distinct phases of transport: without rotor rotation, with rotor rotation while on the ground, and at level flight. Four US-credentialed emergency physicians evaluated M-mode US tracings of the model along with examples from human lungs, both with and without pneumothorax, in random fashion. Results: A total of 104 images were reviewed (26 images per reviewer). All of the M-mode images were correctly identified. Motion artifact was noted on the M-mode tracings taken during rotor rotation, which was greatest during level flight. The rotor artifact was not felt to affect the diagnostic utility of the M-mode US tracing. Conclusion: M-mode US may be used successfully to detect the SLS during helicopter transport.

UR - http://www.scopus.com/inward/record.url?scp=84869451092&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84869451092&partnerID=8YFLogxK

U2 - 10.1016/j.ajem.2011.08.022

DO - 10.1016/j.ajem.2011.08.022

M3 - Article

C2 - 22033387

AN - SCOPUS:84869451092

VL - 30

SP - 1577

EP - 1580

JO - American Journal of Emergency Medicine

JF - American Journal of Emergency Medicine

SN - 0735-6757

IS - 8

ER -