Micromorphological changes in resin-dentin bonds after 1 year of water storage

Masanori Hashimoto, Hiroki Ohno, Hidehiko Sano, Franklin Chi Meng Tay, Masayuki Kaga, Yoshiyuki Kudou, Haruhisa Oguchi, Yoshima Araki, Minoru Kubota

Research output: Contribution to journalArticle

195 Citations (Scopus)

Abstract

The purpose of this study was to evaluate the degradation of resin-dentin bonds after 1 year of water storage. Resin-dentin-bonded specimens were prepared with the use of an adhesive resin system (One-Step: Bisco). Half of the experimental specimens were sectioned perpendicular to the adhesive interface to produce a beam (adhesive area: 0.9 mm2) before being stored in distilled water at 37°C for 1 year. The remaining half of the bonded specimens were sectioned into beams of similar dimensions after 1 year of water storage. Additional bonded specimens that had been stored in water for 24 h before sectioning into beams were used as controls. The beams in the two experimental groups and the control group were subjected to microtensile bond testing. Fractography was performed on all fractured beams with the use of FE-SEM. There were significant (p < .05) differences in bond strength among the control specimens (55.9 ± 12.9 MPa), specimens that had been sectioned into beams after water storage (68.9 ± 18.6 MPa), and specimens that had been sectioned into beams before water storage (28.1 ± 9.3 MPa). Fractography revealed that the resin material was gradually extracted from the periphery to the center portion of the beam. This probably accounted for the decrease in bond strength after 1 year of water storage.

Original languageEnglish (US)
Pages (from-to)306-311
Number of pages6
JournalJournal of Biomedical Materials Research
Volume63
Issue number3
DOIs
StatePublished - May 27 2002
Externally publishedYes

Fingerprint

Dentin
Resins
Water
Adhesives
Fractography
Degradation
Control Groups
Scanning electron microscopy
Testing

Keywords

  • Degradation
  • Fractographic analysis
  • Hybrid layer
  • Microtensile bond test
  • Water storage testing

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials

Cite this

Micromorphological changes in resin-dentin bonds after 1 year of water storage. / Hashimoto, Masanori; Ohno, Hiroki; Sano, Hidehiko; Tay, Franklin Chi Meng; Kaga, Masayuki; Kudou, Yoshiyuki; Oguchi, Haruhisa; Araki, Yoshima; Kubota, Minoru.

In: Journal of Biomedical Materials Research, Vol. 63, No. 3, 27.05.2002, p. 306-311.

Research output: Contribution to journalArticle

Hashimoto, M, Ohno, H, Sano, H, Tay, FCM, Kaga, M, Kudou, Y, Oguchi, H, Araki, Y & Kubota, M 2002, 'Micromorphological changes in resin-dentin bonds after 1 year of water storage', Journal of Biomedical Materials Research, vol. 63, no. 3, pp. 306-311. https://doi.org/10.1002/jbm.10208
Hashimoto, Masanori ; Ohno, Hiroki ; Sano, Hidehiko ; Tay, Franklin Chi Meng ; Kaga, Masayuki ; Kudou, Yoshiyuki ; Oguchi, Haruhisa ; Araki, Yoshima ; Kubota, Minoru. / Micromorphological changes in resin-dentin bonds after 1 year of water storage. In: Journal of Biomedical Materials Research. 2002 ; Vol. 63, No. 3. pp. 306-311.
@article{236174b7b199446da64ab567c06abcf4,
title = "Micromorphological changes in resin-dentin bonds after 1 year of water storage",
abstract = "The purpose of this study was to evaluate the degradation of resin-dentin bonds after 1 year of water storage. Resin-dentin-bonded specimens were prepared with the use of an adhesive resin system (One-Step: Bisco). Half of the experimental specimens were sectioned perpendicular to the adhesive interface to produce a beam (adhesive area: 0.9 mm2) before being stored in distilled water at 37°C for 1 year. The remaining half of the bonded specimens were sectioned into beams of similar dimensions after 1 year of water storage. Additional bonded specimens that had been stored in water for 24 h before sectioning into beams were used as controls. The beams in the two experimental groups and the control group were subjected to microtensile bond testing. Fractography was performed on all fractured beams with the use of FE-SEM. There were significant (p < .05) differences in bond strength among the control specimens (55.9 ± 12.9 MPa), specimens that had been sectioned into beams after water storage (68.9 ± 18.6 MPa), and specimens that had been sectioned into beams before water storage (28.1 ± 9.3 MPa). Fractography revealed that the resin material was gradually extracted from the periphery to the center portion of the beam. This probably accounted for the decrease in bond strength after 1 year of water storage.",
keywords = "Degradation, Fractographic analysis, Hybrid layer, Microtensile bond test, Water storage testing",
author = "Masanori Hashimoto and Hiroki Ohno and Hidehiko Sano and Tay, {Franklin Chi Meng} and Masayuki Kaga and Yoshiyuki Kudou and Haruhisa Oguchi and Yoshima Araki and Minoru Kubota",
year = "2002",
month = "5",
day = "27",
doi = "10.1002/jbm.10208",
language = "English (US)",
volume = "63",
pages = "306--311",
journal = "Journal of Biomedical Materials Research - Part A",
issn = "0021-9304",
publisher = "Heterocorporation",
number = "3",

}

TY - JOUR

T1 - Micromorphological changes in resin-dentin bonds after 1 year of water storage

AU - Hashimoto, Masanori

AU - Ohno, Hiroki

AU - Sano, Hidehiko

AU - Tay, Franklin Chi Meng

AU - Kaga, Masayuki

AU - Kudou, Yoshiyuki

AU - Oguchi, Haruhisa

AU - Araki, Yoshima

AU - Kubota, Minoru

PY - 2002/5/27

Y1 - 2002/5/27

N2 - The purpose of this study was to evaluate the degradation of resin-dentin bonds after 1 year of water storage. Resin-dentin-bonded specimens were prepared with the use of an adhesive resin system (One-Step: Bisco). Half of the experimental specimens were sectioned perpendicular to the adhesive interface to produce a beam (adhesive area: 0.9 mm2) before being stored in distilled water at 37°C for 1 year. The remaining half of the bonded specimens were sectioned into beams of similar dimensions after 1 year of water storage. Additional bonded specimens that had been stored in water for 24 h before sectioning into beams were used as controls. The beams in the two experimental groups and the control group were subjected to microtensile bond testing. Fractography was performed on all fractured beams with the use of FE-SEM. There were significant (p < .05) differences in bond strength among the control specimens (55.9 ± 12.9 MPa), specimens that had been sectioned into beams after water storage (68.9 ± 18.6 MPa), and specimens that had been sectioned into beams before water storage (28.1 ± 9.3 MPa). Fractography revealed that the resin material was gradually extracted from the periphery to the center portion of the beam. This probably accounted for the decrease in bond strength after 1 year of water storage.

AB - The purpose of this study was to evaluate the degradation of resin-dentin bonds after 1 year of water storage. Resin-dentin-bonded specimens were prepared with the use of an adhesive resin system (One-Step: Bisco). Half of the experimental specimens were sectioned perpendicular to the adhesive interface to produce a beam (adhesive area: 0.9 mm2) before being stored in distilled water at 37°C for 1 year. The remaining half of the bonded specimens were sectioned into beams of similar dimensions after 1 year of water storage. Additional bonded specimens that had been stored in water for 24 h before sectioning into beams were used as controls. The beams in the two experimental groups and the control group were subjected to microtensile bond testing. Fractography was performed on all fractured beams with the use of FE-SEM. There were significant (p < .05) differences in bond strength among the control specimens (55.9 ± 12.9 MPa), specimens that had been sectioned into beams after water storage (68.9 ± 18.6 MPa), and specimens that had been sectioned into beams before water storage (28.1 ± 9.3 MPa). Fractography revealed that the resin material was gradually extracted from the periphery to the center portion of the beam. This probably accounted for the decrease in bond strength after 1 year of water storage.

KW - Degradation

KW - Fractographic analysis

KW - Hybrid layer

KW - Microtensile bond test

KW - Water storage testing

UR - http://www.scopus.com/inward/record.url?scp=0036095030&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036095030&partnerID=8YFLogxK

U2 - 10.1002/jbm.10208

DO - 10.1002/jbm.10208

M3 - Article

C2 - 12115762

AN - SCOPUS:0036095030

VL - 63

SP - 306

EP - 311

JO - Journal of Biomedical Materials Research - Part A

JF - Journal of Biomedical Materials Research - Part A

SN - 0021-9304

IS - 3

ER -