Nanoleakage at the dentin adhesive interface vs microtensile bond strength.

S. J. Paul, D. A. Welter, M. Ghazi, David Henry Pashley

Research output: Contribution to journalArticle

96 Citations (Scopus)

Abstract

Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond and the leakage of silver ions within the hybrid layer. After etching occlusal dentin for 15, 30, or 60 seconds with 35% phosphoric acid gel, Single Bond was applied and cured for 10 seconds. Z100 was added and cured for 60 seconds. After 24 hours of water immersion, the teeth were sectioned into slices 0.7 mm thick, and hour-glass-shaped specimens were prepared. Alternate slices were either dried for 30 minutes in air, kept wet, or they were coated with fingernail varnish except for 0.5 mm around the bonded area. Only the varnished samples were then stained with 50% AgNO3. Microtensile bond strength was tested using a Vitrodyne V-1000 universal tester. The samples of the stained group were embedded in self-curing PMMA and polished. All samples were observed with an SEM. Nanoleakage of silver ions was measured by exposure to laser ablation with an inductively connected plasma mass spectrometer and by electron dispersive elemental analysis. Increasing etching times seemed to have a negligible effect on bond strength of Single Bond, producing an average value of ca 38 MPa. However, the silver uptake increased upon prolonged etching times. Short-term results suggest that overetching has no detrimental effect on bond strength values of Single Bond. However, increased silver uptake, depending on the etching time, raises concern about the long-term stability of the bond.

Original languageEnglish (US)
Pages (from-to)181-188
Number of pages8
JournalOperative dentistry
Volume24
Issue number3
StatePublished - Jan 1 1999

Fingerprint

Dentin
Silver
Adhesives
Ions
Paint
Laser Therapy
Immersion
Polymethyl Methacrylate
Nails
Glass
Tooth
Collagen
Gels
Air
Electrons
single bond
Water

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Paul, S. J., Welter, D. A., Ghazi, M., & Pashley, D. H. (1999). Nanoleakage at the dentin adhesive interface vs microtensile bond strength. Operative dentistry, 24(3), 181-188.

Nanoleakage at the dentin adhesive interface vs microtensile bond strength. / Paul, S. J.; Welter, D. A.; Ghazi, M.; Pashley, David Henry.

In: Operative dentistry, Vol. 24, No. 3, 01.01.1999, p. 181-188.

Research output: Contribution to journalArticle

Paul, SJ, Welter, DA, Ghazi, M & Pashley, DH 1999, 'Nanoleakage at the dentin adhesive interface vs microtensile bond strength.', Operative dentistry, vol. 24, no. 3, pp. 181-188.
Paul SJ, Welter DA, Ghazi M, Pashley DH. Nanoleakage at the dentin adhesive interface vs microtensile bond strength. Operative dentistry. 1999 Jan 1;24(3):181-188.
Paul, S. J. ; Welter, D. A. ; Ghazi, M. ; Pashley, David Henry. / Nanoleakage at the dentin adhesive interface vs microtensile bond strength. In: Operative dentistry. 1999 ; Vol. 24, No. 3. pp. 181-188.
@article{17777673db4342468b743b17e3f0cf2b,
title = "Nanoleakage at the dentin adhesive interface vs microtensile bond strength.",
abstract = "Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond and the leakage of silver ions within the hybrid layer. After etching occlusal dentin for 15, 30, or 60 seconds with 35{\%} phosphoric acid gel, Single Bond was applied and cured for 10 seconds. Z100 was added and cured for 60 seconds. After 24 hours of water immersion, the teeth were sectioned into slices 0.7 mm thick, and hour-glass-shaped specimens were prepared. Alternate slices were either dried for 30 minutes in air, kept wet, or they were coated with fingernail varnish except for 0.5 mm around the bonded area. Only the varnished samples were then stained with 50{\%} AgNO3. Microtensile bond strength was tested using a Vitrodyne V-1000 universal tester. The samples of the stained group were embedded in self-curing PMMA and polished. All samples were observed with an SEM. Nanoleakage of silver ions was measured by exposure to laser ablation with an inductively connected plasma mass spectrometer and by electron dispersive elemental analysis. Increasing etching times seemed to have a negligible effect on bond strength of Single Bond, producing an average value of ca 38 MPa. However, the silver uptake increased upon prolonged etching times. Short-term results suggest that overetching has no detrimental effect on bond strength values of Single Bond. However, increased silver uptake, depending on the etching time, raises concern about the long-term stability of the bond.",
author = "Paul, {S. J.} and Welter, {D. A.} and M. Ghazi and Pashley, {David Henry}",
year = "1999",
month = "1",
day = "1",
language = "English (US)",
volume = "24",
pages = "181--188",
journal = "Operative Dentistry",
issn = "0361-7734",
publisher = "Indiana University School of Dentistry",
number = "3",

}

TY - JOUR

T1 - Nanoleakage at the dentin adhesive interface vs microtensile bond strength.

AU - Paul, S. J.

AU - Welter, D. A.

AU - Ghazi, M.

AU - Pashley, David Henry

PY - 1999/1/1

Y1 - 1999/1/1

N2 - Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond and the leakage of silver ions within the hybrid layer. After etching occlusal dentin for 15, 30, or 60 seconds with 35% phosphoric acid gel, Single Bond was applied and cured for 10 seconds. Z100 was added and cured for 60 seconds. After 24 hours of water immersion, the teeth were sectioned into slices 0.7 mm thick, and hour-glass-shaped specimens were prepared. Alternate slices were either dried for 30 minutes in air, kept wet, or they were coated with fingernail varnish except for 0.5 mm around the bonded area. Only the varnished samples were then stained with 50% AgNO3. Microtensile bond strength was tested using a Vitrodyne V-1000 universal tester. The samples of the stained group were embedded in self-curing PMMA and polished. All samples were observed with an SEM. Nanoleakage of silver ions was measured by exposure to laser ablation with an inductively connected plasma mass spectrometer and by electron dispersive elemental analysis. Increasing etching times seemed to have a negligible effect on bond strength of Single Bond, producing an average value of ca 38 MPa. However, the silver uptake increased upon prolonged etching times. Short-term results suggest that overetching has no detrimental effect on bond strength values of Single Bond. However, increased silver uptake, depending on the etching time, raises concern about the long-term stability of the bond.

AB - Excessive etching of the dentin may decrease bond strength because the adhesive may fail to completely infiltrate to the base of the over-etched demineralized collagen network. The purpose of the present study was to evaluate the influence of increasing etching times on the microtensile bond strength of Single Bond and the leakage of silver ions within the hybrid layer. After etching occlusal dentin for 15, 30, or 60 seconds with 35% phosphoric acid gel, Single Bond was applied and cured for 10 seconds. Z100 was added and cured for 60 seconds. After 24 hours of water immersion, the teeth were sectioned into slices 0.7 mm thick, and hour-glass-shaped specimens were prepared. Alternate slices were either dried for 30 minutes in air, kept wet, or they were coated with fingernail varnish except for 0.5 mm around the bonded area. Only the varnished samples were then stained with 50% AgNO3. Microtensile bond strength was tested using a Vitrodyne V-1000 universal tester. The samples of the stained group were embedded in self-curing PMMA and polished. All samples were observed with an SEM. Nanoleakage of silver ions was measured by exposure to laser ablation with an inductively connected plasma mass spectrometer and by electron dispersive elemental analysis. Increasing etching times seemed to have a negligible effect on bond strength of Single Bond, producing an average value of ca 38 MPa. However, the silver uptake increased upon prolonged etching times. Short-term results suggest that overetching has no detrimental effect on bond strength values of Single Bond. However, increased silver uptake, depending on the etching time, raises concern about the long-term stability of the bond.

UR - http://www.scopus.com/inward/record.url?scp=0033127821&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033127821&partnerID=8YFLogxK

M3 - Article

C2 - 10530280

AN - SCOPUS:0033127821

VL - 24

SP - 181

EP - 188

JO - Operative Dentistry

JF - Operative Dentistry

SN - 0361-7734

IS - 3

ER -