New design of the amplatzer membranous VSD occluder

A step forward?

Kiran Mallula, Najma Patel, Zahid Amin

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Closure of perimembranous ventricular septal defects (PmVSDs) [4] with the original Amplatzer membranous VSD occluder (mVSD1) has been associated with an increased risk of complications, the most notable of which has been complete heart block. This has led to the introduction of a new device to close PmVSDs. The authors describe their experience with the new Amplatzer membranous VSD occluder (mVSD2) in two patients and critique the new device design and delivery system, comparing it with the mVSD1 occluder. Two patients underwent attempted closure of PmVSDs with the new mVSD2 device. One patient had successful closure of the defect with no residual shunt and no evidence of heart block at follow-up evaluation. Trace to mild aortic insufficiency was observed at the time of closure and at the last follow-up visit. The rhythm remained sinus. In the second patient, the device was placed but removed before release because of inability to orient the device in optimal position. Percutaneous closure of PmVSD is feasible with the new mVSD2 occluder. The change in the design may reduce the incidence of complete heart block. It remains to be seen whether the device will be suitable for smaller patients.

Original languageEnglish (US)
Pages (from-to)2068-2072
Number of pages5
JournalPediatric Cardiology
Volume34
Issue number8
DOIs
StatePublished - Dec 1 2013
Externally publishedYes

Fingerprint

Ventricular Heart Septal Defects
Heart Block
Equipment and Supplies
Equipment Design
Incidence

Keywords

  • Percutaneous
  • Perimembranous
  • Transcatheter
  • VSD
  • Ventricular septal defect

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Cardiology and Cardiovascular Medicine

Cite this

New design of the amplatzer membranous VSD occluder : A step forward? / Mallula, Kiran; Patel, Najma; Amin, Zahid.

In: Pediatric Cardiology, Vol. 34, No. 8, 01.12.2013, p. 2068-2072.

Research output: Contribution to journalArticle

Mallula, Kiran ; Patel, Najma ; Amin, Zahid. / New design of the amplatzer membranous VSD occluder : A step forward?. In: Pediatric Cardiology. 2013 ; Vol. 34, No. 8. pp. 2068-2072.
@article{843524118e584063b67cb5b6c7225b3c,
title = "New design of the amplatzer membranous VSD occluder: A step forward?",
abstract = "Closure of perimembranous ventricular septal defects (PmVSDs) [4] with the original Amplatzer membranous VSD occluder (mVSD1) has been associated with an increased risk of complications, the most notable of which has been complete heart block. This has led to the introduction of a new device to close PmVSDs. The authors describe their experience with the new Amplatzer membranous VSD occluder (mVSD2) in two patients and critique the new device design and delivery system, comparing it with the mVSD1 occluder. Two patients underwent attempted closure of PmVSDs with the new mVSD2 device. One patient had successful closure of the defect with no residual shunt and no evidence of heart block at follow-up evaluation. Trace to mild aortic insufficiency was observed at the time of closure and at the last follow-up visit. The rhythm remained sinus. In the second patient, the device was placed but removed before release because of inability to orient the device in optimal position. Percutaneous closure of PmVSD is feasible with the new mVSD2 occluder. The change in the design may reduce the incidence of complete heart block. It remains to be seen whether the device will be suitable for smaller patients.",
keywords = "Percutaneous, Perimembranous, Transcatheter, VSD, Ventricular septal defect",
author = "Kiran Mallula and Najma Patel and Zahid Amin",
year = "2013",
month = "12",
day = "1",
doi = "10.1007/s00246-013-0636-1",
language = "English (US)",
volume = "34",
pages = "2068--2072",
journal = "Pediatric Cardiology",
issn = "0172-0643",
publisher = "Springer New York",
number = "8",

}

TY - JOUR

T1 - New design of the amplatzer membranous VSD occluder

T2 - A step forward?

AU - Mallula, Kiran

AU - Patel, Najma

AU - Amin, Zahid

PY - 2013/12/1

Y1 - 2013/12/1

N2 - Closure of perimembranous ventricular septal defects (PmVSDs) [4] with the original Amplatzer membranous VSD occluder (mVSD1) has been associated with an increased risk of complications, the most notable of which has been complete heart block. This has led to the introduction of a new device to close PmVSDs. The authors describe their experience with the new Amplatzer membranous VSD occluder (mVSD2) in two patients and critique the new device design and delivery system, comparing it with the mVSD1 occluder. Two patients underwent attempted closure of PmVSDs with the new mVSD2 device. One patient had successful closure of the defect with no residual shunt and no evidence of heart block at follow-up evaluation. Trace to mild aortic insufficiency was observed at the time of closure and at the last follow-up visit. The rhythm remained sinus. In the second patient, the device was placed but removed before release because of inability to orient the device in optimal position. Percutaneous closure of PmVSD is feasible with the new mVSD2 occluder. The change in the design may reduce the incidence of complete heart block. It remains to be seen whether the device will be suitable for smaller patients.

AB - Closure of perimembranous ventricular septal defects (PmVSDs) [4] with the original Amplatzer membranous VSD occluder (mVSD1) has been associated with an increased risk of complications, the most notable of which has been complete heart block. This has led to the introduction of a new device to close PmVSDs. The authors describe their experience with the new Amplatzer membranous VSD occluder (mVSD2) in two patients and critique the new device design and delivery system, comparing it with the mVSD1 occluder. Two patients underwent attempted closure of PmVSDs with the new mVSD2 device. One patient had successful closure of the defect with no residual shunt and no evidence of heart block at follow-up evaluation. Trace to mild aortic insufficiency was observed at the time of closure and at the last follow-up visit. The rhythm remained sinus. In the second patient, the device was placed but removed before release because of inability to orient the device in optimal position. Percutaneous closure of PmVSD is feasible with the new mVSD2 occluder. The change in the design may reduce the incidence of complete heart block. It remains to be seen whether the device will be suitable for smaller patients.

KW - Percutaneous

KW - Perimembranous

KW - Transcatheter

KW - VSD

KW - Ventricular septal defect

UR - http://www.scopus.com/inward/record.url?scp=84889573370&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84889573370&partnerID=8YFLogxK

U2 - 10.1007/s00246-013-0636-1

DO - 10.1007/s00246-013-0636-1

M3 - Article

VL - 34

SP - 2068

EP - 2072

JO - Pediatric Cardiology

JF - Pediatric Cardiology

SN - 0172-0643

IS - 8

ER -