Precision for Computer-Guided Implant Placement: Using 3D Planning Software and Fixed Intraoral Reference Points

Stefan Holst, Markus B. Blatz, Stephan Eitner

Research output: Contribution to journalArticle

38 Citations (Scopus)

Abstract

Purpose: The aim of this article is to describe the application of screws as fixed intraoral reference points for stable, precise, and repeatable positioning of diagnostic and surgical templates for implant placement. Materials and Methods: Currently available software programs in combination with computed tomography data allow 3-dimensional treatment planning in demanding clinical situations prior to implant placement. One drawback of most systems is the lack of stability and support of both radiographic and surgical templates in edentulous patients. The characteristics and application of a new screw system in combination with computer assisted 3-dimensional implant placement are specified. Results: Implants were placed exactly as projected without impairment of the mandibular nerve despite close proximity of the mental foramen. Conclusion: Precision and accuracy of computer-based or -supported implant placement is valuable only if an exact transfer to the intraoral situation is granted. Depending on the clinical patient situation, fixed intraoral reference points can improve precision in an efficient manner.

Original languageEnglish (US)
Pages (from-to)393-399
Number of pages7
JournalJournal of Oral and Maxillofacial Surgery
Volume65
Issue number3
DOIs
StatePublished - Mar 1 2007

Fingerprint

Software
Mandibular Nerve
Tomography
Therapeutics

ASJC Scopus subject areas

  • Surgery
  • Oral Surgery
  • Otorhinolaryngology

Cite this

Precision for Computer-Guided Implant Placement : Using 3D Planning Software and Fixed Intraoral Reference Points. / Holst, Stefan; Blatz, Markus B.; Eitner, Stephan.

In: Journal of Oral and Maxillofacial Surgery, Vol. 65, No. 3, 01.03.2007, p. 393-399.

Research output: Contribution to journalArticle

@article{5107747b2225458d84d7359bb3de6b74,
title = "Precision for Computer-Guided Implant Placement: Using 3D Planning Software and Fixed Intraoral Reference Points",
abstract = "Purpose: The aim of this article is to describe the application of screws as fixed intraoral reference points for stable, precise, and repeatable positioning of diagnostic and surgical templates for implant placement. Materials and Methods: Currently available software programs in combination with computed tomography data allow 3-dimensional treatment planning in demanding clinical situations prior to implant placement. One drawback of most systems is the lack of stability and support of both radiographic and surgical templates in edentulous patients. The characteristics and application of a new screw system in combination with computer assisted 3-dimensional implant placement are specified. Results: Implants were placed exactly as projected without impairment of the mandibular nerve despite close proximity of the mental foramen. Conclusion: Precision and accuracy of computer-based or -supported implant placement is valuable only if an exact transfer to the intraoral situation is granted. Depending on the clinical patient situation, fixed intraoral reference points can improve precision in an efficient manner.",
author = "Stefan Holst and Blatz, {Markus B.} and Stephan Eitner",
year = "2007",
month = "3",
day = "1",
doi = "10.1016/j.joms.2006.10.050",
language = "English (US)",
volume = "65",
pages = "393--399",
journal = "Journal of Oral and Maxillofacial Surgery",
issn = "0278-2391",
publisher = "W.B. Saunders Ltd",
number = "3",

}

TY - JOUR

T1 - Precision for Computer-Guided Implant Placement

T2 - Using 3D Planning Software and Fixed Intraoral Reference Points

AU - Holst, Stefan

AU - Blatz, Markus B.

AU - Eitner, Stephan

PY - 2007/3/1

Y1 - 2007/3/1

N2 - Purpose: The aim of this article is to describe the application of screws as fixed intraoral reference points for stable, precise, and repeatable positioning of diagnostic and surgical templates for implant placement. Materials and Methods: Currently available software programs in combination with computed tomography data allow 3-dimensional treatment planning in demanding clinical situations prior to implant placement. One drawback of most systems is the lack of stability and support of both radiographic and surgical templates in edentulous patients. The characteristics and application of a new screw system in combination with computer assisted 3-dimensional implant placement are specified. Results: Implants were placed exactly as projected without impairment of the mandibular nerve despite close proximity of the mental foramen. Conclusion: Precision and accuracy of computer-based or -supported implant placement is valuable only if an exact transfer to the intraoral situation is granted. Depending on the clinical patient situation, fixed intraoral reference points can improve precision in an efficient manner.

AB - Purpose: The aim of this article is to describe the application of screws as fixed intraoral reference points for stable, precise, and repeatable positioning of diagnostic and surgical templates for implant placement. Materials and Methods: Currently available software programs in combination with computed tomography data allow 3-dimensional treatment planning in demanding clinical situations prior to implant placement. One drawback of most systems is the lack of stability and support of both radiographic and surgical templates in edentulous patients. The characteristics and application of a new screw system in combination with computer assisted 3-dimensional implant placement are specified. Results: Implants were placed exactly as projected without impairment of the mandibular nerve despite close proximity of the mental foramen. Conclusion: Precision and accuracy of computer-based or -supported implant placement is valuable only if an exact transfer to the intraoral situation is granted. Depending on the clinical patient situation, fixed intraoral reference points can improve precision in an efficient manner.

UR - http://www.scopus.com/inward/record.url?scp=33847284114&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33847284114&partnerID=8YFLogxK

U2 - 10.1016/j.joms.2006.10.050

DO - 10.1016/j.joms.2006.10.050

M3 - Article

C2 - 17307583

AN - SCOPUS:33847284114

VL - 65

SP - 393

EP - 399

JO - Journal of Oral and Maxillofacial Surgery

JF - Journal of Oral and Maxillofacial Surgery

SN - 0278-2391

IS - 3

ER -