Abstract

We have studied reconstruction methods currently available for use in quantitative brain SPECT imaging. The conventional reconstruction methods are based on the filtered backprojection algorithm. Assuming uniform attenuation, the Chang algorithm is effective in attenuation compensation. The collimator response can be compensated for by restoration filter with an average collimator response function. Scatter compensation can be achieved by the dual window subtraction method or by incorporating an average scatter response function in the restoration filter. The dual window subtraction method is an approximate but efficient means of providing scatter compensated projection data. Iteration reconstruction method can be applied to these data for addition compensation for attenuation and the spatially variant collimator response. The latter is accomplished by incorporating the exact model of attenuation and detector response function in the projector / backprojector of the iterative algorithm. A three-dimensional brain phantom was used in the evaluation study. Projection data were collected into the photopeak and a lower scatter energy windows for scatter compensation. The images obtained from various reconstruction methods were compared for quantitative accuracy with respect to the known 3D phantom activity distribution.

Original languageEnglish (US)
Pages (from-to)214-220
Number of pages7
JournalIEEE Transactions on Nuclear Science
Volume40
Issue number2
DOIs
StatePublished - Jan 1 1993

Fingerprint

brain
Brain
collimators
attenuation
Restoration
subtraction
restoration
projection
photopeak
filters
projectors
iteration
Detectors
Imaging techniques
Compensation and Redress
evaluation
detectors
energy

ASJC Scopus subject areas

  • Nuclear Energy and Engineering
  • Electrical and Electronic Engineering
  • Nuclear and High Energy Physics

Cite this

Tsui, B. M. W., Zhao, X. D., Cao, Z. J., & Frey, E. C. (1993). Reconstruction Methods for Quantitative Brain SPECT. IEEE Transactions on Nuclear Science, 40(2), 214-220. https://doi.org/10.1109/23.212344

Reconstruction Methods for Quantitative Brain SPECT. / Tsui, B. M W; Zhao, X. D.; Cao, Z. J.; Frey, E. C.

In: IEEE Transactions on Nuclear Science, Vol. 40, No. 2, 01.01.1993, p. 214-220.

Research output: Contribution to journalArticle

Tsui, BMW, Zhao, XD, Cao, ZJ & Frey, EC 1993, 'Reconstruction Methods for Quantitative Brain SPECT', IEEE Transactions on Nuclear Science, vol. 40, no. 2, pp. 214-220. https://doi.org/10.1109/23.212344
Tsui, B. M W ; Zhao, X. D. ; Cao, Z. J. ; Frey, E. C. / Reconstruction Methods for Quantitative Brain SPECT. In: IEEE Transactions on Nuclear Science. 1993 ; Vol. 40, No. 2. pp. 214-220.
@article{b2f81198644049bfafef3ba4eda4d990,
title = "Reconstruction Methods for Quantitative Brain SPECT",
abstract = "We have studied reconstruction methods currently available for use in quantitative brain SPECT imaging. The conventional reconstruction methods are based on the filtered backprojection algorithm. Assuming uniform attenuation, the Chang algorithm is effective in attenuation compensation. The collimator response can be compensated for by restoration filter with an average collimator response function. Scatter compensation can be achieved by the dual window subtraction method or by incorporating an average scatter response function in the restoration filter. The dual window subtraction method is an approximate but efficient means of providing scatter compensated projection data. Iteration reconstruction method can be applied to these data for addition compensation for attenuation and the spatially variant collimator response. The latter is accomplished by incorporating the exact model of attenuation and detector response function in the projector / backprojector of the iterative algorithm. A three-dimensional brain phantom was used in the evaluation study. Projection data were collected into the photopeak and a lower scatter energy windows for scatter compensation. The images obtained from various reconstruction methods were compared for quantitative accuracy with respect to the known 3D phantom activity distribution.",
author = "Tsui, {B. M W} and Zhao, {X. D.} and Cao, {Z. J.} and Frey, {E. C.}",
year = "1993",
month = "1",
day = "1",
doi = "10.1109/23.212344",
language = "English (US)",
volume = "40",
pages = "214--220",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

TY - JOUR

T1 - Reconstruction Methods for Quantitative Brain SPECT

AU - Tsui, B. M W

AU - Zhao, X. D.

AU - Cao, Z. J.

AU - Frey, E. C.

PY - 1993/1/1

Y1 - 1993/1/1

N2 - We have studied reconstruction methods currently available for use in quantitative brain SPECT imaging. The conventional reconstruction methods are based on the filtered backprojection algorithm. Assuming uniform attenuation, the Chang algorithm is effective in attenuation compensation. The collimator response can be compensated for by restoration filter with an average collimator response function. Scatter compensation can be achieved by the dual window subtraction method or by incorporating an average scatter response function in the restoration filter. The dual window subtraction method is an approximate but efficient means of providing scatter compensated projection data. Iteration reconstruction method can be applied to these data for addition compensation for attenuation and the spatially variant collimator response. The latter is accomplished by incorporating the exact model of attenuation and detector response function in the projector / backprojector of the iterative algorithm. A three-dimensional brain phantom was used in the evaluation study. Projection data were collected into the photopeak and a lower scatter energy windows for scatter compensation. The images obtained from various reconstruction methods were compared for quantitative accuracy with respect to the known 3D phantom activity distribution.

AB - We have studied reconstruction methods currently available for use in quantitative brain SPECT imaging. The conventional reconstruction methods are based on the filtered backprojection algorithm. Assuming uniform attenuation, the Chang algorithm is effective in attenuation compensation. The collimator response can be compensated for by restoration filter with an average collimator response function. Scatter compensation can be achieved by the dual window subtraction method or by incorporating an average scatter response function in the restoration filter. The dual window subtraction method is an approximate but efficient means of providing scatter compensated projection data. Iteration reconstruction method can be applied to these data for addition compensation for attenuation and the spatially variant collimator response. The latter is accomplished by incorporating the exact model of attenuation and detector response function in the projector / backprojector of the iterative algorithm. A three-dimensional brain phantom was used in the evaluation study. Projection data were collected into the photopeak and a lower scatter energy windows for scatter compensation. The images obtained from various reconstruction methods were compared for quantitative accuracy with respect to the known 3D phantom activity distribution.

UR - http://www.scopus.com/inward/record.url?scp=0027574651&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027574651&partnerID=8YFLogxK

U2 - 10.1109/23.212344

DO - 10.1109/23.212344

M3 - Article

VL - 40

SP - 214

EP - 220

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 2

ER -