Reliability of electromyographic normalization methods for evaluating the hip musculature

Lori Ann Bolgla, Timothy L. Uhl

Research output: Contribution to journalArticle

93 Citations (Scopus)

Abstract

The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum voluntary isometric contraction (MVIC), mean dynamic (m-DYN), and peak dynamic activity (pk-DYN). Intraclass coefficient correlations (ICCs), intersubject coefficients of variation (CVs), and intrasubject CVs were then calculated for each normalization method. MVIC ICCs exceeded 0.93 for all exercises. M-DYN and pk-DYN ICCs exceeded 0.85 for all exercises except for the sidelying abduction exercise. Intersubject CVs ranged from 55% to 77% and 19% to 61% for the MVIC and dynamic methods, respectively. Intrasubject CVs ranged from 11% to 22% for all exercises under all normalization methods. The MVIC method provided the highest measurement reliability for determining differences in activation amplitudes between hip abductor exercises in healthy subjects. Future research should determine if these same results would apply to a symptomatic patient population.

Original languageEnglish (US)
Pages (from-to)102-111
Number of pages10
JournalJournal of Electromyography and Kinesiology
Volume17
Issue number1
DOIs
StatePublished - Feb 1 2007

Fingerprint

Hip
Exercise
Isometric Contraction
Healthy Volunteers
Exercise Therapy
Population

Keywords

  • Electromyography
  • Gluteus medius
  • Hip exercises
  • Measurement
  • Normalization
  • Rehabilitation
  • Reproducibility

ASJC Scopus subject areas

  • Neuroscience (miscellaneous)
  • Biophysics
  • Clinical Neurology

Cite this

Reliability of electromyographic normalization methods for evaluating the hip musculature. / Bolgla, Lori Ann; Uhl, Timothy L.

In: Journal of Electromyography and Kinesiology, Vol. 17, No. 1, 01.02.2007, p. 102-111.

Research output: Contribution to journalArticle

@article{5392193edcb241fc9c4ae244147e6c06,
title = "Reliability of electromyographic normalization methods for evaluating the hip musculature",
abstract = "The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum voluntary isometric contraction (MVIC), mean dynamic (m-DYN), and peak dynamic activity (pk-DYN). Intraclass coefficient correlations (ICCs), intersubject coefficients of variation (CVs), and intrasubject CVs were then calculated for each normalization method. MVIC ICCs exceeded 0.93 for all exercises. M-DYN and pk-DYN ICCs exceeded 0.85 for all exercises except for the sidelying abduction exercise. Intersubject CVs ranged from 55{\%} to 77{\%} and 19{\%} to 61{\%} for the MVIC and dynamic methods, respectively. Intrasubject CVs ranged from 11{\%} to 22{\%} for all exercises under all normalization methods. The MVIC method provided the highest measurement reliability for determining differences in activation amplitudes between hip abductor exercises in healthy subjects. Future research should determine if these same results would apply to a symptomatic patient population.",
keywords = "Electromyography, Gluteus medius, Hip exercises, Measurement, Normalization, Rehabilitation, Reproducibility",
author = "Bolgla, {Lori Ann} and Uhl, {Timothy L.}",
year = "2007",
month = "2",
day = "1",
doi = "10.1016/j.jelekin.2005.11.007",
language = "English (US)",
volume = "17",
pages = "102--111",
journal = "Journal of Electromyography and Kinesiology",
issn = "1050-6411",
publisher = "Elsevier Limited",
number = "1",

}

TY - JOUR

T1 - Reliability of electromyographic normalization methods for evaluating the hip musculature

AU - Bolgla, Lori Ann

AU - Uhl, Timothy L.

PY - 2007/2/1

Y1 - 2007/2/1

N2 - The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum voluntary isometric contraction (MVIC), mean dynamic (m-DYN), and peak dynamic activity (pk-DYN). Intraclass coefficient correlations (ICCs), intersubject coefficients of variation (CVs), and intrasubject CVs were then calculated for each normalization method. MVIC ICCs exceeded 0.93 for all exercises. M-DYN and pk-DYN ICCs exceeded 0.85 for all exercises except for the sidelying abduction exercise. Intersubject CVs ranged from 55% to 77% and 19% to 61% for the MVIC and dynamic methods, respectively. Intrasubject CVs ranged from 11% to 22% for all exercises under all normalization methods. The MVIC method provided the highest measurement reliability for determining differences in activation amplitudes between hip abductor exercises in healthy subjects. Future research should determine if these same results would apply to a symptomatic patient population.

AB - The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum voluntary isometric contraction (MVIC), mean dynamic (m-DYN), and peak dynamic activity (pk-DYN). Intraclass coefficient correlations (ICCs), intersubject coefficients of variation (CVs), and intrasubject CVs were then calculated for each normalization method. MVIC ICCs exceeded 0.93 for all exercises. M-DYN and pk-DYN ICCs exceeded 0.85 for all exercises except for the sidelying abduction exercise. Intersubject CVs ranged from 55% to 77% and 19% to 61% for the MVIC and dynamic methods, respectively. Intrasubject CVs ranged from 11% to 22% for all exercises under all normalization methods. The MVIC method provided the highest measurement reliability for determining differences in activation amplitudes between hip abductor exercises in healthy subjects. Future research should determine if these same results would apply to a symptomatic patient population.

KW - Electromyography

KW - Gluteus medius

KW - Hip exercises

KW - Measurement

KW - Normalization

KW - Rehabilitation

KW - Reproducibility

UR - http://www.scopus.com/inward/record.url?scp=33750976379&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750976379&partnerID=8YFLogxK

U2 - 10.1016/j.jelekin.2005.11.007

DO - 10.1016/j.jelekin.2005.11.007

M3 - Article

C2 - 16423539

AN - SCOPUS:33750976379

VL - 17

SP - 102

EP - 111

JO - Journal of Electromyography and Kinesiology

JF - Journal of Electromyography and Kinesiology

SN - 1050-6411

IS - 1

ER -