Resistance to thermo-mechanical stress of different coupling agents used as intermediate layer in resin-fiber post bonds

Francesca Monticelli, Raquel Osorio, Franklin Chi Meng Tay, Fernanda T. Sadek, Marco Ferrari, Manuel Toledano

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Purpose: To evaluate the microtensile bond strength (MTBS) of different coupling agents used in fiber post-composite bonds to withstand different in vitro challenging procedures. Methods: 63 fiber posts (DT Light Post) etched with 10% hydrogen peroxide were divided into three groups according to the silane/adhesive system applied: (1) Porcelain Bond Activator (PBA) + Clearfil SE Bond; (2) PBA + Clearfil Tri S Bond; (3) Monobond-S. A composite build-up (Clearfil AP-X) was performed around the post producing cylindrical specimens that were divided into three subgroups according to the different aging protocol: (1) 24-hour storage at room temperature; (2) Thermocycling (5000 cycles, 5°/55°C dwell time: 30 seconds); (3) Cyclic loading (45° angle, 20,000 cycles, load 5-50 N at 3.0 Hz). Samples were then cut obtaining sticks that were loaded in tension until failure. Bond strength values were statistically analyzed with two-way ANOVA and Tukey test (α = 0.05). Failure mode was recorded and the morphologic aspect of post/core interface after aging was evaluated under SEM. Results: Both post superficial treatment, thermocycling and cyclic loading influenced bond strength. After 24 hours, samples treated with silane/adhesive couplings attained higher MTBS than those bonded with conventional silane. No significant differences in the microtensile bond strength at the post/core interface were recorded between the different silane/adhesive couplings. After challenging, no differences were found between the tested groups.

Original languageEnglish (US)
Pages (from-to)416-420
Number of pages5
JournalAmerican journal of dentistry
Volume20
Issue number6
StatePublished - Dec 1 2007

Fingerprint

Silanes
Mechanical Stress
Adhesives
Dental Porcelain
Hydrogen Peroxide
Analysis of Variance
Light
Temperature

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Resistance to thermo-mechanical stress of different coupling agents used as intermediate layer in resin-fiber post bonds. / Monticelli, Francesca; Osorio, Raquel; Tay, Franklin Chi Meng; Sadek, Fernanda T.; Ferrari, Marco; Toledano, Manuel.

In: American journal of dentistry, Vol. 20, No. 6, 01.12.2007, p. 416-420.

Research output: Contribution to journalArticle

Monticelli, Francesca ; Osorio, Raquel ; Tay, Franklin Chi Meng ; Sadek, Fernanda T. ; Ferrari, Marco ; Toledano, Manuel. / Resistance to thermo-mechanical stress of different coupling agents used as intermediate layer in resin-fiber post bonds. In: American journal of dentistry. 2007 ; Vol. 20, No. 6. pp. 416-420.
@article{52780f68603f4423a2e3a8052aaac3ea,
title = "Resistance to thermo-mechanical stress of different coupling agents used as intermediate layer in resin-fiber post bonds",
abstract = "Purpose: To evaluate the microtensile bond strength (MTBS) of different coupling agents used in fiber post-composite bonds to withstand different in vitro challenging procedures. Methods: 63 fiber posts (DT Light Post) etched with 10{\%} hydrogen peroxide were divided into three groups according to the silane/adhesive system applied: (1) Porcelain Bond Activator (PBA) + Clearfil SE Bond; (2) PBA + Clearfil Tri S Bond; (3) Monobond-S. A composite build-up (Clearfil AP-X) was performed around the post producing cylindrical specimens that were divided into three subgroups according to the different aging protocol: (1) 24-hour storage at room temperature; (2) Thermocycling (5000 cycles, 5°/55°C dwell time: 30 seconds); (3) Cyclic loading (45° angle, 20,000 cycles, load 5-50 N at 3.0 Hz). Samples were then cut obtaining sticks that were loaded in tension until failure. Bond strength values were statistically analyzed with two-way ANOVA and Tukey test (α = 0.05). Failure mode was recorded and the morphologic aspect of post/core interface after aging was evaluated under SEM. Results: Both post superficial treatment, thermocycling and cyclic loading influenced bond strength. After 24 hours, samples treated with silane/adhesive couplings attained higher MTBS than those bonded with conventional silane. No significant differences in the microtensile bond strength at the post/core interface were recorded between the different silane/adhesive couplings. After challenging, no differences were found between the tested groups.",
author = "Francesca Monticelli and Raquel Osorio and Tay, {Franklin Chi Meng} and Sadek, {Fernanda T.} and Marco Ferrari and Manuel Toledano",
year = "2007",
month = "12",
day = "1",
language = "English (US)",
volume = "20",
pages = "416--420",
journal = "American Journal of Dentistry",
issn = "0894-8275",
publisher = "Mosher and Linder, Inc",
number = "6",

}

TY - JOUR

T1 - Resistance to thermo-mechanical stress of different coupling agents used as intermediate layer in resin-fiber post bonds

AU - Monticelli, Francesca

AU - Osorio, Raquel

AU - Tay, Franklin Chi Meng

AU - Sadek, Fernanda T.

AU - Ferrari, Marco

AU - Toledano, Manuel

PY - 2007/12/1

Y1 - 2007/12/1

N2 - Purpose: To evaluate the microtensile bond strength (MTBS) of different coupling agents used in fiber post-composite bonds to withstand different in vitro challenging procedures. Methods: 63 fiber posts (DT Light Post) etched with 10% hydrogen peroxide were divided into three groups according to the silane/adhesive system applied: (1) Porcelain Bond Activator (PBA) + Clearfil SE Bond; (2) PBA + Clearfil Tri S Bond; (3) Monobond-S. A composite build-up (Clearfil AP-X) was performed around the post producing cylindrical specimens that were divided into three subgroups according to the different aging protocol: (1) 24-hour storage at room temperature; (2) Thermocycling (5000 cycles, 5°/55°C dwell time: 30 seconds); (3) Cyclic loading (45° angle, 20,000 cycles, load 5-50 N at 3.0 Hz). Samples were then cut obtaining sticks that were loaded in tension until failure. Bond strength values were statistically analyzed with two-way ANOVA and Tukey test (α = 0.05). Failure mode was recorded and the morphologic aspect of post/core interface after aging was evaluated under SEM. Results: Both post superficial treatment, thermocycling and cyclic loading influenced bond strength. After 24 hours, samples treated with silane/adhesive couplings attained higher MTBS than those bonded with conventional silane. No significant differences in the microtensile bond strength at the post/core interface were recorded between the different silane/adhesive couplings. After challenging, no differences were found between the tested groups.

AB - Purpose: To evaluate the microtensile bond strength (MTBS) of different coupling agents used in fiber post-composite bonds to withstand different in vitro challenging procedures. Methods: 63 fiber posts (DT Light Post) etched with 10% hydrogen peroxide were divided into three groups according to the silane/adhesive system applied: (1) Porcelain Bond Activator (PBA) + Clearfil SE Bond; (2) PBA + Clearfil Tri S Bond; (3) Monobond-S. A composite build-up (Clearfil AP-X) was performed around the post producing cylindrical specimens that were divided into three subgroups according to the different aging protocol: (1) 24-hour storage at room temperature; (2) Thermocycling (5000 cycles, 5°/55°C dwell time: 30 seconds); (3) Cyclic loading (45° angle, 20,000 cycles, load 5-50 N at 3.0 Hz). Samples were then cut obtaining sticks that were loaded in tension until failure. Bond strength values were statistically analyzed with two-way ANOVA and Tukey test (α = 0.05). Failure mode was recorded and the morphologic aspect of post/core interface after aging was evaluated under SEM. Results: Both post superficial treatment, thermocycling and cyclic loading influenced bond strength. After 24 hours, samples treated with silane/adhesive couplings attained higher MTBS than those bonded with conventional silane. No significant differences in the microtensile bond strength at the post/core interface were recorded between the different silane/adhesive couplings. After challenging, no differences were found between the tested groups.

UR - http://www.scopus.com/inward/record.url?scp=38349149836&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=38349149836&partnerID=8YFLogxK

M3 - Article

C2 - 18269136

AN - SCOPUS:38349149836

VL - 20

SP - 416

EP - 420

JO - American Journal of Dentistry

JF - American Journal of Dentistry

SN - 0894-8275

IS - 6

ER -