Silicone-coated thin film array cochlear implantation in a feline model

Jessica M. Van Beek-King, Pamela T. Bhatti, David Trumbull Blake, Jonathan Crawford, Brian J. McKinnon

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

OBJECTIVES: Some limitations of cochlear implants can be attributed to a restricted spectral representation of sound provided by contemporary electrode arrays. Microfabricated high-density thin film array (TFA) technology enables a greater density of stimulating sites and, thus, a more complete spectral representation. Previous pilot cadaveric studies have documented insertion characteristics, although not electrical characteristics. STUDY DESIGN: Electrode evoked auditory brainstem response (ABR) testing in a feline model. METHODS: Six healthy, normal hearing cats were unilaterally deafened and implanted with a silicone coated TFA, measuring 27.8 × 0.4 × 80μm (L × W × H). Monopolar stimulation of single electrodes was used to evoke a triple peaked ABR. Thresholds to evoke a minimal ABR were determined. RESULTS: All 6 cats underwent successful full insertion and activation. Thresholds to evoke minimal ABR's varied among implants ranging from 75 to 450 μA. Over the basal portion of the array, thresholds were either larger or unable to evoke an ABR. CONCLUSION: Two-thirds of the implants showed ABR's along the entire array, whereas the others evoked ABR's at the apical end and less robustly more basally. This may reflect increased distance of the electrodes from the modiolus, as the basal half of the array is narrower relative to the width of the scala. A tapered design to ensure array distance to modiolus is minimized may enable the basal half of the arrays to stimulate more consistently.

Original languageEnglish (US)
JournalOtology and Neurotology
Volume35
Issue number1
DOIs
StatePublished - Jan 1 2014

Fingerprint

Cochlear Implantation
Brain Stem Auditory Evoked Potentials
Felidae
Silicones
Electrodes
Cats
Cochlear Implants
Hearing
Technology

Keywords

  • Cochlear implant
  • Thin film array
  • microfabricated array

ASJC Scopus subject areas

  • Otorhinolaryngology
  • Sensory Systems
  • Clinical Neurology

Cite this

Silicone-coated thin film array cochlear implantation in a feline model. / Van Beek-King, Jessica M.; Bhatti, Pamela T.; Blake, David Trumbull; Crawford, Jonathan; McKinnon, Brian J.

In: Otology and Neurotology, Vol. 35, No. 1, 01.01.2014.

Research output: Contribution to journalArticle

Van Beek-King, Jessica M. ; Bhatti, Pamela T. ; Blake, David Trumbull ; Crawford, Jonathan ; McKinnon, Brian J. / Silicone-coated thin film array cochlear implantation in a feline model. In: Otology and Neurotology. 2014 ; Vol. 35, No. 1.
@article{94e9921787b64d2ab867c402b7677bdb,
title = "Silicone-coated thin film array cochlear implantation in a feline model",
abstract = "OBJECTIVES: Some limitations of cochlear implants can be attributed to a restricted spectral representation of sound provided by contemporary electrode arrays. Microfabricated high-density thin film array (TFA) technology enables a greater density of stimulating sites and, thus, a more complete spectral representation. Previous pilot cadaveric studies have documented insertion characteristics, although not electrical characteristics. STUDY DESIGN: Electrode evoked auditory brainstem response (ABR) testing in a feline model. METHODS: Six healthy, normal hearing cats were unilaterally deafened and implanted with a silicone coated TFA, measuring 27.8 × 0.4 × 80μm (L × W × H). Monopolar stimulation of single electrodes was used to evoke a triple peaked ABR. Thresholds to evoke a minimal ABR were determined. RESULTS: All 6 cats underwent successful full insertion and activation. Thresholds to evoke minimal ABR's varied among implants ranging from 75 to 450 μA. Over the basal portion of the array, thresholds were either larger or unable to evoke an ABR. CONCLUSION: Two-thirds of the implants showed ABR's along the entire array, whereas the others evoked ABR's at the apical end and less robustly more basally. This may reflect increased distance of the electrodes from the modiolus, as the basal half of the array is narrower relative to the width of the scala. A tapered design to ensure array distance to modiolus is minimized may enable the basal half of the arrays to stimulate more consistently.",
keywords = "Cochlear implant, Thin film array, microfabricated array",
author = "{Van Beek-King}, {Jessica M.} and Bhatti, {Pamela T.} and Blake, {David Trumbull} and Jonathan Crawford and McKinnon, {Brian J.}",
year = "2014",
month = "1",
day = "1",
doi = "10.1097/MAO.0000000000000186",
language = "English (US)",
volume = "35",
journal = "Otology and Neurotology",
issn = "1531-7129",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Silicone-coated thin film array cochlear implantation in a feline model

AU - Van Beek-King, Jessica M.

AU - Bhatti, Pamela T.

AU - Blake, David Trumbull

AU - Crawford, Jonathan

AU - McKinnon, Brian J.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - OBJECTIVES: Some limitations of cochlear implants can be attributed to a restricted spectral representation of sound provided by contemporary electrode arrays. Microfabricated high-density thin film array (TFA) technology enables a greater density of stimulating sites and, thus, a more complete spectral representation. Previous pilot cadaveric studies have documented insertion characteristics, although not electrical characteristics. STUDY DESIGN: Electrode evoked auditory brainstem response (ABR) testing in a feline model. METHODS: Six healthy, normal hearing cats were unilaterally deafened and implanted with a silicone coated TFA, measuring 27.8 × 0.4 × 80μm (L × W × H). Monopolar stimulation of single electrodes was used to evoke a triple peaked ABR. Thresholds to evoke a minimal ABR were determined. RESULTS: All 6 cats underwent successful full insertion and activation. Thresholds to evoke minimal ABR's varied among implants ranging from 75 to 450 μA. Over the basal portion of the array, thresholds were either larger or unable to evoke an ABR. CONCLUSION: Two-thirds of the implants showed ABR's along the entire array, whereas the others evoked ABR's at the apical end and less robustly more basally. This may reflect increased distance of the electrodes from the modiolus, as the basal half of the array is narrower relative to the width of the scala. A tapered design to ensure array distance to modiolus is minimized may enable the basal half of the arrays to stimulate more consistently.

AB - OBJECTIVES: Some limitations of cochlear implants can be attributed to a restricted spectral representation of sound provided by contemporary electrode arrays. Microfabricated high-density thin film array (TFA) technology enables a greater density of stimulating sites and, thus, a more complete spectral representation. Previous pilot cadaveric studies have documented insertion characteristics, although not electrical characteristics. STUDY DESIGN: Electrode evoked auditory brainstem response (ABR) testing in a feline model. METHODS: Six healthy, normal hearing cats were unilaterally deafened and implanted with a silicone coated TFA, measuring 27.8 × 0.4 × 80μm (L × W × H). Monopolar stimulation of single electrodes was used to evoke a triple peaked ABR. Thresholds to evoke a minimal ABR were determined. RESULTS: All 6 cats underwent successful full insertion and activation. Thresholds to evoke minimal ABR's varied among implants ranging from 75 to 450 μA. Over the basal portion of the array, thresholds were either larger or unable to evoke an ABR. CONCLUSION: Two-thirds of the implants showed ABR's along the entire array, whereas the others evoked ABR's at the apical end and less robustly more basally. This may reflect increased distance of the electrodes from the modiolus, as the basal half of the array is narrower relative to the width of the scala. A tapered design to ensure array distance to modiolus is minimized may enable the basal half of the arrays to stimulate more consistently.

KW - Cochlear implant

KW - Thin film array

KW - microfabricated array

UR - http://www.scopus.com/inward/record.url?scp=84891836775&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84891836775&partnerID=8YFLogxK

U2 - 10.1097/MAO.0000000000000186

DO - 10.1097/MAO.0000000000000186

M3 - Article

VL - 35

JO - Otology and Neurotology

JF - Otology and Neurotology

SN - 1531-7129

IS - 1

ER -