Abstract

Circular dichroism and fluorescence polarization anisotropy are important tools for characterizing biomolecular systems. Both are used extensively in kinetic experiments involving stopped- or continuous flow systems as well as titrations and steady-state spectroscopy. This paper presents the theory for determining circular dichroism and fluorescence polarization anisotropy simultaneously, thus insuring the two parameters are recorded under exactly the same conditions and at exactly the same time in kinetic experiments. The approach to measuring circular dichroism is that used in almost all conventional dichrographs. Two arrangements for measuring fluorescence polarization anisotropy are described. One uses a single fluorescence detector and signal processing with a lock-in amplifier that is similar to the measurement of circular dichroism. The second approach uses classic "T" format detection optics, and thus can be used with conventional photon-counting detection electronics. Simple extensions permit the simultaneous measurement of the absorption and excitation intensity corrected fluorescence intensity.

Original languageEnglish (US)
Pages (from-to)126-136
Number of pages11
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume4625
DOIs
StatePublished - Jan 1 2002
EventClinical Diagnostic Systems: Technologies and Instrumentation - San Jose, CA, United States
Duration: Jan 22 2002Jan 24 2002

Fingerprint

Dichroism
Fluorescence
dichroism
Anisotropy
Polarization
fluorescence
anisotropy
polarization
Kinetics
Photon Counting
kinetics
Titration
titration
format
Experiment
Signal Processing
Two Parameters
Spectroscopy
Optics
signal processing

Keywords

  • Circular dichroism
  • Fluorescence polarization anisotropy
  • Photoelastic modulator
  • Stopped flow kinetics
  • Ultraviolet absorption spectra

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

Cite this

@article{4d6e5892b9a344b1af5b28db5f887efd,
title = "Simultaneous measurement of circular dichroism and fluorescence polarization anisotropy",
abstract = "Circular dichroism and fluorescence polarization anisotropy are important tools for characterizing biomolecular systems. Both are used extensively in kinetic experiments involving stopped- or continuous flow systems as well as titrations and steady-state spectroscopy. This paper presents the theory for determining circular dichroism and fluorescence polarization anisotropy simultaneously, thus insuring the two parameters are recorded under exactly the same conditions and at exactly the same time in kinetic experiments. The approach to measuring circular dichroism is that used in almost all conventional dichrographs. Two arrangements for measuring fluorescence polarization anisotropy are described. One uses a single fluorescence detector and signal processing with a lock-in amplifier that is similar to the measurement of circular dichroism. The second approach uses classic {"}T{"} format detection optics, and thus can be used with conventional photon-counting detection electronics. Simple extensions permit the simultaneous measurement of the absorption and excitation intensity corrected fluorescence intensity.",
keywords = "Circular dichroism, Fluorescence polarization anisotropy, Photoelastic modulator, Stopped flow kinetics, Ultraviolet absorption spectra",
author = "Sutherland, {John C.}",
year = "2002",
month = "1",
day = "1",
doi = "10.1117/12.469782",
language = "English (US)",
volume = "4625",
pages = "126--136",
journal = "Proceedings of SPIE - The International Society for Optical Engineering",
issn = "0277-786X",
publisher = "SPIE",

}

TY - JOUR

T1 - Simultaneous measurement of circular dichroism and fluorescence polarization anisotropy

AU - Sutherland, John C.

PY - 2002/1/1

Y1 - 2002/1/1

N2 - Circular dichroism and fluorescence polarization anisotropy are important tools for characterizing biomolecular systems. Both are used extensively in kinetic experiments involving stopped- or continuous flow systems as well as titrations and steady-state spectroscopy. This paper presents the theory for determining circular dichroism and fluorescence polarization anisotropy simultaneously, thus insuring the two parameters are recorded under exactly the same conditions and at exactly the same time in kinetic experiments. The approach to measuring circular dichroism is that used in almost all conventional dichrographs. Two arrangements for measuring fluorescence polarization anisotropy are described. One uses a single fluorescence detector and signal processing with a lock-in amplifier that is similar to the measurement of circular dichroism. The second approach uses classic "T" format detection optics, and thus can be used with conventional photon-counting detection electronics. Simple extensions permit the simultaneous measurement of the absorption and excitation intensity corrected fluorescence intensity.

AB - Circular dichroism and fluorescence polarization anisotropy are important tools for characterizing biomolecular systems. Both are used extensively in kinetic experiments involving stopped- or continuous flow systems as well as titrations and steady-state spectroscopy. This paper presents the theory for determining circular dichroism and fluorescence polarization anisotropy simultaneously, thus insuring the two parameters are recorded under exactly the same conditions and at exactly the same time in kinetic experiments. The approach to measuring circular dichroism is that used in almost all conventional dichrographs. Two arrangements for measuring fluorescence polarization anisotropy are described. One uses a single fluorescence detector and signal processing with a lock-in amplifier that is similar to the measurement of circular dichroism. The second approach uses classic "T" format detection optics, and thus can be used with conventional photon-counting detection electronics. Simple extensions permit the simultaneous measurement of the absorption and excitation intensity corrected fluorescence intensity.

KW - Circular dichroism

KW - Fluorescence polarization anisotropy

KW - Photoelastic modulator

KW - Stopped flow kinetics

KW - Ultraviolet absorption spectra

UR - http://www.scopus.com/inward/record.url?scp=0036407159&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036407159&partnerID=8YFLogxK

U2 - 10.1117/12.469782

DO - 10.1117/12.469782

M3 - Conference article

AN - SCOPUS:0036407159

VL - 4625

SP - 126

EP - 136

JO - Proceedings of SPIE - The International Society for Optical Engineering

JF - Proceedings of SPIE - The International Society for Optical Engineering

SN - 0277-786X

ER -