SU‐FF‐T‐199

Dosimetry Validation for Spinal Cord Irradiation In Extracranial Stereotactic Radiosurgery

S. li, Y. Liu, Q. Chen, JianYue Jin, S. Ryu, B. Movsas

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Purpose: A single large dose in the range of 16 to 20 Gray at 90% isodose line can be safely delivered to solitary or multiple metastases in the vertebral column via extracranial stereotactic radiosurgery. However, the spinal cord dose is usually limited to 10 Gy within the treatment segment. Thus, the dosimetry validation for the spinal cord is critical for this procedure and for further dose escalation. Methods and Materials: Bearing the challenges of the great dose gradient and irregular shape of the target around the cord, we have designed an experiment to measure the absolute dose to the cord using a farm chamber placed at the location of the spine cord inside the solid water phantom. The air‐cavity of the chamber is precisely delineated in the iPlan system (BrainLAB) and dose volume histogram for the air cavity was used for calculating the effective dose in the treatment plan. This can then be compared with measured doses by the chamber. Isodose distributions in two coronal planes through the center of tumor and through the cord are also measured with EDR2 films and compared with the planned dose distributions. Results: Our tests demonstrated that this dosimetry measurement is reliable with high accuracy and precision of < 3% deviation in such difficult dosimetry verification. Results from five spinal SRS cases show that the cord doses with IMRS plans are within 5 % from those of the treatment planned doses. Importantly, the isodose distributions at the cord and near the target volume are consistent with the planed dose distributions. Conclusions: The small discrepancies (up to 5%) for the absolute dose measurement show no gross errors in the dose delivery and dose calculation using a pencil beam algorithm in the planning system.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume33
Issue number6
DOIs
StatePublished - Jan 1 2006

Fingerprint

Radiosurgery
Spinal Cord
Spine
Therapeutics
Air
Neoplasm Metastasis
Water
Neoplasms

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐FF‐T‐199 : Dosimetry Validation for Spinal Cord Irradiation In Extracranial Stereotactic Radiosurgery. / li, S.; Liu, Y.; Chen, Q.; Jin, JianYue; Ryu, S.; Movsas, B.

In: Medical Physics, Vol. 33, No. 6, 01.01.2006.

Research output: Contribution to journalArticle

li, S. ; Liu, Y. ; Chen, Q. ; Jin, JianYue ; Ryu, S. ; Movsas, B. / SU‐FF‐T‐199 : Dosimetry Validation for Spinal Cord Irradiation In Extracranial Stereotactic Radiosurgery. In: Medical Physics. 2006 ; Vol. 33, No. 6.
@article{4a8dd7a0fd09424eab3555dbdaaeaac8,
title = "SU‐FF‐T‐199: Dosimetry Validation for Spinal Cord Irradiation In Extracranial Stereotactic Radiosurgery",
abstract = "Purpose: A single large dose in the range of 16 to 20 Gray at 90{\%} isodose line can be safely delivered to solitary or multiple metastases in the vertebral column via extracranial stereotactic radiosurgery. However, the spinal cord dose is usually limited to 10 Gy within the treatment segment. Thus, the dosimetry validation for the spinal cord is critical for this procedure and for further dose escalation. Methods and Materials: Bearing the challenges of the great dose gradient and irregular shape of the target around the cord, we have designed an experiment to measure the absolute dose to the cord using a farm chamber placed at the location of the spine cord inside the solid water phantom. The air‐cavity of the chamber is precisely delineated in the iPlan system (BrainLAB) and dose volume histogram for the air cavity was used for calculating the effective dose in the treatment plan. This can then be compared with measured doses by the chamber. Isodose distributions in two coronal planes through the center of tumor and through the cord are also measured with EDR2 films and compared with the planned dose distributions. Results: Our tests demonstrated that this dosimetry measurement is reliable with high accuracy and precision of < 3{\%} deviation in such difficult dosimetry verification. Results from five spinal SRS cases show that the cord doses with IMRS plans are within 5 {\%} from those of the treatment planned doses. Importantly, the isodose distributions at the cord and near the target volume are consistent with the planed dose distributions. Conclusions: The small discrepancies (up to 5{\%}) for the absolute dose measurement show no gross errors in the dose delivery and dose calculation using a pencil beam algorithm in the planning system.",
author = "S. li and Y. Liu and Q. Chen and JianYue Jin and S. Ryu and B. Movsas",
year = "2006",
month = "1",
day = "1",
doi = "10.1118/1.2241122",
language = "English (US)",
volume = "33",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐FF‐T‐199

T2 - Dosimetry Validation for Spinal Cord Irradiation In Extracranial Stereotactic Radiosurgery

AU - li, S.

AU - Liu, Y.

AU - Chen, Q.

AU - Jin, JianYue

AU - Ryu, S.

AU - Movsas, B.

PY - 2006/1/1

Y1 - 2006/1/1

N2 - Purpose: A single large dose in the range of 16 to 20 Gray at 90% isodose line can be safely delivered to solitary or multiple metastases in the vertebral column via extracranial stereotactic radiosurgery. However, the spinal cord dose is usually limited to 10 Gy within the treatment segment. Thus, the dosimetry validation for the spinal cord is critical for this procedure and for further dose escalation. Methods and Materials: Bearing the challenges of the great dose gradient and irregular shape of the target around the cord, we have designed an experiment to measure the absolute dose to the cord using a farm chamber placed at the location of the spine cord inside the solid water phantom. The air‐cavity of the chamber is precisely delineated in the iPlan system (BrainLAB) and dose volume histogram for the air cavity was used for calculating the effective dose in the treatment plan. This can then be compared with measured doses by the chamber. Isodose distributions in two coronal planes through the center of tumor and through the cord are also measured with EDR2 films and compared with the planned dose distributions. Results: Our tests demonstrated that this dosimetry measurement is reliable with high accuracy and precision of < 3% deviation in such difficult dosimetry verification. Results from five spinal SRS cases show that the cord doses with IMRS plans are within 5 % from those of the treatment planned doses. Importantly, the isodose distributions at the cord and near the target volume are consistent with the planed dose distributions. Conclusions: The small discrepancies (up to 5%) for the absolute dose measurement show no gross errors in the dose delivery and dose calculation using a pencil beam algorithm in the planning system.

AB - Purpose: A single large dose in the range of 16 to 20 Gray at 90% isodose line can be safely delivered to solitary or multiple metastases in the vertebral column via extracranial stereotactic radiosurgery. However, the spinal cord dose is usually limited to 10 Gy within the treatment segment. Thus, the dosimetry validation for the spinal cord is critical for this procedure and for further dose escalation. Methods and Materials: Bearing the challenges of the great dose gradient and irregular shape of the target around the cord, we have designed an experiment to measure the absolute dose to the cord using a farm chamber placed at the location of the spine cord inside the solid water phantom. The air‐cavity of the chamber is precisely delineated in the iPlan system (BrainLAB) and dose volume histogram for the air cavity was used for calculating the effective dose in the treatment plan. This can then be compared with measured doses by the chamber. Isodose distributions in two coronal planes through the center of tumor and through the cord are also measured with EDR2 films and compared with the planned dose distributions. Results: Our tests demonstrated that this dosimetry measurement is reliable with high accuracy and precision of < 3% deviation in such difficult dosimetry verification. Results from five spinal SRS cases show that the cord doses with IMRS plans are within 5 % from those of the treatment planned doses. Importantly, the isodose distributions at the cord and near the target volume are consistent with the planed dose distributions. Conclusions: The small discrepancies (up to 5%) for the absolute dose measurement show no gross errors in the dose delivery and dose calculation using a pencil beam algorithm in the planning system.

UR - http://www.scopus.com/inward/record.url?scp=79251604333&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79251604333&partnerID=8YFLogxK

U2 - 10.1118/1.2241122

DO - 10.1118/1.2241122

M3 - Article

VL - 33

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -