Tensile strength of human dentin as a function of tubule orientation and density

Ricardo M. Carvalho, Carlos A.O. Fernandes, Romel Villanueva, Linda Wang, David H. Pashley

Research output: Contribution to journalArticle

56 Citations (Scopus)

Abstract

Purpose: This study investigated the ultimate tensile strength (UTS) of human dentin as a function of tubule orientation and density. Materials and Methods: Slabs of dentin (ca 0.7 mm thick) were obtained from human third molars by either transversally or longitudinally sectioning the crowns with an Isomet saw. The slabs were gently trimmed to reduce the central area of the coronal dentin to a cross-sectional area of approximately 0.5 mm2. The longitudinally sectioned slabs were either trimmed from the mesial and distal sides or from the occlusal and pulpal aspects to permit the tensile load to be applied either parallel or perpendicular to the tubule orientation. The transversally sectioned specimens were obtained at several distances from the pulp and were used to evaluate the effects of tubule density. The trimmed specimens were tested in tension on a Kratos testing machine at 0.5 mm/min. After failure, the UTS of each was calculated and expressed in MPa. The fractured ends of the transversally sectioned specimens were viewed under SEM to calculate the number of tubules per mm2 at the site of fracture, and its relation with the UTS was investigated by regression analysis. Results: The UTS of dentin is higher when the load is applied perpendicular to the tubule orientation (80 ± 13 MPa) than when applied parallel to tubule orientation (58 ± 11 MPa, p < 0.05). There was a tendency for dentin to be weaker as the number of tubules at the site of fracture increased, although this relationship was not statistically significant (R2 = 0.051, p 0.05). Conclusion: The UTS of dentin is dependent on the tubule direction. Dentin tends to be weaker as the number of tubules per area increases.

Original languageEnglish (US)
Pages (from-to)309-314
Number of pages6
JournalJournal of Adhesive Dentistry
Volume3
Issue number4
StatePublished - Dec 1 2001

Fingerprint

Tensile Strength
Dentin
Third Molar
Crowns
Regression Analysis

ASJC Scopus subject areas

  • Orthodontics
  • Oral Surgery
  • Periodontics

Cite this

Carvalho, R. M., Fernandes, C. A. O., Villanueva, R., Wang, L., & Pashley, D. H. (2001). Tensile strength of human dentin as a function of tubule orientation and density. Journal of Adhesive Dentistry, 3(4), 309-314.

Tensile strength of human dentin as a function of tubule orientation and density. / Carvalho, Ricardo M.; Fernandes, Carlos A.O.; Villanueva, Romel; Wang, Linda; Pashley, David H.

In: Journal of Adhesive Dentistry, Vol. 3, No. 4, 01.12.2001, p. 309-314.

Research output: Contribution to journalArticle

Carvalho, RM, Fernandes, CAO, Villanueva, R, Wang, L & Pashley, DH 2001, 'Tensile strength of human dentin as a function of tubule orientation and density', Journal of Adhesive Dentistry, vol. 3, no. 4, pp. 309-314.
Carvalho RM, Fernandes CAO, Villanueva R, Wang L, Pashley DH. Tensile strength of human dentin as a function of tubule orientation and density. Journal of Adhesive Dentistry. 2001 Dec 1;3(4):309-314.
Carvalho, Ricardo M. ; Fernandes, Carlos A.O. ; Villanueva, Romel ; Wang, Linda ; Pashley, David H. / Tensile strength of human dentin as a function of tubule orientation and density. In: Journal of Adhesive Dentistry. 2001 ; Vol. 3, No. 4. pp. 309-314.
@article{09b5a320452d4896b796585a6813e45f,
title = "Tensile strength of human dentin as a function of tubule orientation and density",
abstract = "Purpose: This study investigated the ultimate tensile strength (UTS) of human dentin as a function of tubule orientation and density. Materials and Methods: Slabs of dentin (ca 0.7 mm thick) were obtained from human third molars by either transversally or longitudinally sectioning the crowns with an Isomet saw. The slabs were gently trimmed to reduce the central area of the coronal dentin to a cross-sectional area of approximately 0.5 mm2. The longitudinally sectioned slabs were either trimmed from the mesial and distal sides or from the occlusal and pulpal aspects to permit the tensile load to be applied either parallel or perpendicular to the tubule orientation. The transversally sectioned specimens were obtained at several distances from the pulp and were used to evaluate the effects of tubule density. The trimmed specimens were tested in tension on a Kratos testing machine at 0.5 mm/min. After failure, the UTS of each was calculated and expressed in MPa. The fractured ends of the transversally sectioned specimens were viewed under SEM to calculate the number of tubules per mm2 at the site of fracture, and its relation with the UTS was investigated by regression analysis. Results: The UTS of dentin is higher when the load is applied perpendicular to the tubule orientation (80 ± 13 MPa) than when applied parallel to tubule orientation (58 ± 11 MPa, p < 0.05). There was a tendency for dentin to be weaker as the number of tubules at the site of fracture increased, although this relationship was not statistically significant (R2 = 0.051, p 0.05). Conclusion: The UTS of dentin is dependent on the tubule direction. Dentin tends to be weaker as the number of tubules per area increases.",
author = "Carvalho, {Ricardo M.} and Fernandes, {Carlos A.O.} and Romel Villanueva and Linda Wang and Pashley, {David H.}",
year = "2001",
month = "12",
day = "1",
language = "English (US)",
volume = "3",
pages = "309--314",
journal = "The journal of adhesive dentistry",
issn = "1461-5185",
publisher = "Quintessence Publishing Company",
number = "4",

}

TY - JOUR

T1 - Tensile strength of human dentin as a function of tubule orientation and density

AU - Carvalho, Ricardo M.

AU - Fernandes, Carlos A.O.

AU - Villanueva, Romel

AU - Wang, Linda

AU - Pashley, David H.

PY - 2001/12/1

Y1 - 2001/12/1

N2 - Purpose: This study investigated the ultimate tensile strength (UTS) of human dentin as a function of tubule orientation and density. Materials and Methods: Slabs of dentin (ca 0.7 mm thick) were obtained from human third molars by either transversally or longitudinally sectioning the crowns with an Isomet saw. The slabs were gently trimmed to reduce the central area of the coronal dentin to a cross-sectional area of approximately 0.5 mm2. The longitudinally sectioned slabs were either trimmed from the mesial and distal sides or from the occlusal and pulpal aspects to permit the tensile load to be applied either parallel or perpendicular to the tubule orientation. The transversally sectioned specimens were obtained at several distances from the pulp and were used to evaluate the effects of tubule density. The trimmed specimens were tested in tension on a Kratos testing machine at 0.5 mm/min. After failure, the UTS of each was calculated and expressed in MPa. The fractured ends of the transversally sectioned specimens were viewed under SEM to calculate the number of tubules per mm2 at the site of fracture, and its relation with the UTS was investigated by regression analysis. Results: The UTS of dentin is higher when the load is applied perpendicular to the tubule orientation (80 ± 13 MPa) than when applied parallel to tubule orientation (58 ± 11 MPa, p < 0.05). There was a tendency for dentin to be weaker as the number of tubules at the site of fracture increased, although this relationship was not statistically significant (R2 = 0.051, p 0.05). Conclusion: The UTS of dentin is dependent on the tubule direction. Dentin tends to be weaker as the number of tubules per area increases.

AB - Purpose: This study investigated the ultimate tensile strength (UTS) of human dentin as a function of tubule orientation and density. Materials and Methods: Slabs of dentin (ca 0.7 mm thick) were obtained from human third molars by either transversally or longitudinally sectioning the crowns with an Isomet saw. The slabs were gently trimmed to reduce the central area of the coronal dentin to a cross-sectional area of approximately 0.5 mm2. The longitudinally sectioned slabs were either trimmed from the mesial and distal sides or from the occlusal and pulpal aspects to permit the tensile load to be applied either parallel or perpendicular to the tubule orientation. The transversally sectioned specimens were obtained at several distances from the pulp and were used to evaluate the effects of tubule density. The trimmed specimens were tested in tension on a Kratos testing machine at 0.5 mm/min. After failure, the UTS of each was calculated and expressed in MPa. The fractured ends of the transversally sectioned specimens were viewed under SEM to calculate the number of tubules per mm2 at the site of fracture, and its relation with the UTS was investigated by regression analysis. Results: The UTS of dentin is higher when the load is applied perpendicular to the tubule orientation (80 ± 13 MPa) than when applied parallel to tubule orientation (58 ± 11 MPa, p < 0.05). There was a tendency for dentin to be weaker as the number of tubules at the site of fracture increased, although this relationship was not statistically significant (R2 = 0.051, p 0.05). Conclusion: The UTS of dentin is dependent on the tubule direction. Dentin tends to be weaker as the number of tubules per area increases.

UR - http://www.scopus.com/inward/record.url?scp=0035749650&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035749650&partnerID=8YFLogxK

M3 - Article

C2 - 11893046

AN - SCOPUS:0035749650

VL - 3

SP - 309

EP - 314

JO - The journal of adhesive dentistry

JF - The journal of adhesive dentistry

SN - 1461-5185

IS - 4

ER -