Transcranial Doppler penetrance of methyl methacrylate: Technical note

Th K. Hillers, A. M. Roseland, C. A. Giller

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Methyl methacrylate is often used in cranioplasties and reconstructions of crainiectomies at sites through which transcranial Doppler (TCD) examinations are performed for assessment of cerebral hemodynamics. To assess the penetrance of methyl methacrylate by a transcranial Doppler ultrasound beam, methyl methacrylate discs of thickness from 4 to 10 mm were constructed and placed in the path of the ultrasound beam during routine-insonation of the middle cerebral artery and femoral artery in a healthy volunteer. The quality of ultrasound signals obtainable markedly deteriorated as thicker discs were used, and was almost completely absent at a thickness of 10 mm. The impairment of ultrasound transmission at frequencies used for transcranial Doppler ultrasound by methyl methacrylate is significant and represents a limitation in TCD studies that sould be recognized by the clinician.

Original languageEnglish (US)
Pages (from-to)93-94
Number of pages2
JournalActa Neurochirurgica
Volume133
Issue number1-2
DOIs
StatePublished - Mar 1 1995

Fingerprint

Methacrylates
Penetrance
Doppler Ultrasonography
Middle Cerebral Artery
Femoral Artery
Healthy Volunteers
Hemodynamics

Keywords

  • Cranioplasty
  • methyl methacrylate
  • transcranial Doppler

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Cite this

Transcranial Doppler penetrance of methyl methacrylate : Technical note. / Hillers, Th K.; Roseland, A. M.; Giller, C. A.

In: Acta Neurochirurgica, Vol. 133, No. 1-2, 01.03.1995, p. 93-94.

Research output: Contribution to journalArticle

Hillers, Th K. ; Roseland, A. M. ; Giller, C. A. / Transcranial Doppler penetrance of methyl methacrylate : Technical note. In: Acta Neurochirurgica. 1995 ; Vol. 133, No. 1-2. pp. 93-94.
@article{40c80700958f4b3caef4a7714975fe83,
title = "Transcranial Doppler penetrance of methyl methacrylate: Technical note",
abstract = "Methyl methacrylate is often used in cranioplasties and reconstructions of crainiectomies at sites through which transcranial Doppler (TCD) examinations are performed for assessment of cerebral hemodynamics. To assess the penetrance of methyl methacrylate by a transcranial Doppler ultrasound beam, methyl methacrylate discs of thickness from 4 to 10 mm were constructed and placed in the path of the ultrasound beam during routine-insonation of the middle cerebral artery and femoral artery in a healthy volunteer. The quality of ultrasound signals obtainable markedly deteriorated as thicker discs were used, and was almost completely absent at a thickness of 10 mm. The impairment of ultrasound transmission at frequencies used for transcranial Doppler ultrasound by methyl methacrylate is significant and represents a limitation in TCD studies that sould be recognized by the clinician.",
keywords = "Cranioplasty, methyl methacrylate, transcranial Doppler",
author = "Hillers, {Th K.} and Roseland, {A. M.} and Giller, {C. A.}",
year = "1995",
month = "3",
day = "1",
doi = "10.1007/BF01404956",
language = "English (US)",
volume = "133",
pages = "93--94",
journal = "Acta Neurochirurgica",
issn = "0001-6268",
publisher = "Springer Wien",
number = "1-2",

}

TY - JOUR

T1 - Transcranial Doppler penetrance of methyl methacrylate

T2 - Technical note

AU - Hillers, Th K.

AU - Roseland, A. M.

AU - Giller, C. A.

PY - 1995/3/1

Y1 - 1995/3/1

N2 - Methyl methacrylate is often used in cranioplasties and reconstructions of crainiectomies at sites through which transcranial Doppler (TCD) examinations are performed for assessment of cerebral hemodynamics. To assess the penetrance of methyl methacrylate by a transcranial Doppler ultrasound beam, methyl methacrylate discs of thickness from 4 to 10 mm were constructed and placed in the path of the ultrasound beam during routine-insonation of the middle cerebral artery and femoral artery in a healthy volunteer. The quality of ultrasound signals obtainable markedly deteriorated as thicker discs were used, and was almost completely absent at a thickness of 10 mm. The impairment of ultrasound transmission at frequencies used for transcranial Doppler ultrasound by methyl methacrylate is significant and represents a limitation in TCD studies that sould be recognized by the clinician.

AB - Methyl methacrylate is often used in cranioplasties and reconstructions of crainiectomies at sites through which transcranial Doppler (TCD) examinations are performed for assessment of cerebral hemodynamics. To assess the penetrance of methyl methacrylate by a transcranial Doppler ultrasound beam, methyl methacrylate discs of thickness from 4 to 10 mm were constructed and placed in the path of the ultrasound beam during routine-insonation of the middle cerebral artery and femoral artery in a healthy volunteer. The quality of ultrasound signals obtainable markedly deteriorated as thicker discs were used, and was almost completely absent at a thickness of 10 mm. The impairment of ultrasound transmission at frequencies used for transcranial Doppler ultrasound by methyl methacrylate is significant and represents a limitation in TCD studies that sould be recognized by the clinician.

KW - Cranioplasty

KW - methyl methacrylate

KW - transcranial Doppler

UR - http://www.scopus.com/inward/record.url?scp=0028926124&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028926124&partnerID=8YFLogxK

U2 - 10.1007/BF01404956

DO - 10.1007/BF01404956

M3 - Article

C2 - 8561046

AN - SCOPUS:0028926124

VL - 133

SP - 93

EP - 94

JO - Acta Neurochirurgica

JF - Acta Neurochirurgica

SN - 0001-6268

IS - 1-2