Use of 3-D Freehand Endorectal Ultrasound System with Appropriate Rectal Phantom

J. R. Warmath, Alan Joseph Herline, R. L. Galloway

Research output: Contribution to journalConference article

1 Citation (Scopus)

Abstract

Rectal cancer is a growing problem, and more accurate diagnostic and treatment procedures are needed to improve patient care. The initial study reporting the accuracy of an optically tracked endorectal ultrasound (TERUS) probe using an appropriately designed rectal phantom, for the purpose of improving the care of rectal cancer, is presented here. This work describes the need for a more accurate ERUS system and why the incorporation of image guidance makes this goal feasible. We present the methods of constructing an appropriate rectal phantom and the results of accuracy testing of the TERUS system with the phantom. This study presents a very promising outcome because the required tumor margins for rectal cancer are on the order of centimeters and the proven accuracy is on the order of millimeters.

Original languageEnglish (US)
Pages (from-to)1137-1140
Number of pages4
JournalAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
Volume2
StatePublished - Dec 1 2003
EventA New Beginning for Human Health: Proceddings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society - Cancun, Mexico
Duration: Sep 17 2003Sep 21 2003

Fingerprint

Rectal Neoplasms
Ultrasonics
Tumors
Patient Care
Testing
Neoplasms
Therapeutics

Keywords

  • Endorectal Ultrasound
  • Image-guidance
  • Rectal Cancer

ASJC Scopus subject areas

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Cite this

Use of 3-D Freehand Endorectal Ultrasound System with Appropriate Rectal Phantom. / Warmath, J. R.; Herline, Alan Joseph; Galloway, R. L.

In: Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, Vol. 2, 01.12.2003, p. 1137-1140.

Research output: Contribution to journalConference article

@article{1087cd63fb33434ead5d23d2ec5213a0,
title = "Use of 3-D Freehand Endorectal Ultrasound System with Appropriate Rectal Phantom",
abstract = "Rectal cancer is a growing problem, and more accurate diagnostic and treatment procedures are needed to improve patient care. The initial study reporting the accuracy of an optically tracked endorectal ultrasound (TERUS) probe using an appropriately designed rectal phantom, for the purpose of improving the care of rectal cancer, is presented here. This work describes the need for a more accurate ERUS system and why the incorporation of image guidance makes this goal feasible. We present the methods of constructing an appropriate rectal phantom and the results of accuracy testing of the TERUS system with the phantom. This study presents a very promising outcome because the required tumor margins for rectal cancer are on the order of centimeters and the proven accuracy is on the order of millimeters.",
keywords = "Endorectal Ultrasound, Image-guidance, Rectal Cancer",
author = "Warmath, {J. R.} and Herline, {Alan Joseph} and Galloway, {R. L.}",
year = "2003",
month = "12",
day = "1",
language = "English (US)",
volume = "2",
pages = "1137--1140",
journal = "Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference",
issn = "1557-170X",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - JOUR

T1 - Use of 3-D Freehand Endorectal Ultrasound System with Appropriate Rectal Phantom

AU - Warmath, J. R.

AU - Herline, Alan Joseph

AU - Galloway, R. L.

PY - 2003/12/1

Y1 - 2003/12/1

N2 - Rectal cancer is a growing problem, and more accurate diagnostic and treatment procedures are needed to improve patient care. The initial study reporting the accuracy of an optically tracked endorectal ultrasound (TERUS) probe using an appropriately designed rectal phantom, for the purpose of improving the care of rectal cancer, is presented here. This work describes the need for a more accurate ERUS system and why the incorporation of image guidance makes this goal feasible. We present the methods of constructing an appropriate rectal phantom and the results of accuracy testing of the TERUS system with the phantom. This study presents a very promising outcome because the required tumor margins for rectal cancer are on the order of centimeters and the proven accuracy is on the order of millimeters.

AB - Rectal cancer is a growing problem, and more accurate diagnostic and treatment procedures are needed to improve patient care. The initial study reporting the accuracy of an optically tracked endorectal ultrasound (TERUS) probe using an appropriately designed rectal phantom, for the purpose of improving the care of rectal cancer, is presented here. This work describes the need for a more accurate ERUS system and why the incorporation of image guidance makes this goal feasible. We present the methods of constructing an appropriate rectal phantom and the results of accuracy testing of the TERUS system with the phantom. This study presents a very promising outcome because the required tumor margins for rectal cancer are on the order of centimeters and the proven accuracy is on the order of millimeters.

KW - Endorectal Ultrasound

KW - Image-guidance

KW - Rectal Cancer

UR - http://www.scopus.com/inward/record.url?scp=1542361576&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1542361576&partnerID=8YFLogxK

M3 - Conference article

AN - SCOPUS:1542361576

VL - 2

SP - 1137

EP - 1140

JO - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference

JF - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference

SN - 1557-170X

ER -