A reporter assay for the next generation of biomaterials

Porous-wall hollow glass microspheres

Aaron Cunningham, Hunter Allen Faircloth, Matthew Jones, Christopher Johnson, Tiffany Coleman, George Wicks, Gregory N Postma, Paul Maurice Weinberger

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Objectives/Hypothesis The primary objective was to design a reporter assay to measure molecular release kinetics from a new porous-wall hollow glass microsphere biomaterial with great potential in regenerative medicine and drug delivery. Second, future avenues for research will be discussed specifically in regard to potential clinical uses in laryngology. Study Design Basic science data report. Methods We developed an assay using fluorescent nanocrystals or quantum dots (Qdot 605) as a reporter. A Nuance FX multispectral imaging system was used to detect fluorescence in aqueous phase. Spectral output of known concentrations of aqueous Qdot 605 was measured by the Nuance system to create a standard curve. Results These data were plotted and fit to a curve. Qdot 605 emission demonstrates excellent correlation with concentration in a log-log relationship [R2-=-0.99649, median error-=-9.9%], indicating that the Qdot 605 assay is reliable and should be explored regarding its ability to evaluate the drug-eluting properties of this material. Conclusions We have derived a method to measure Qdot concentration using fluorescent microscopy, which will facilitate future research on this exciting new biomaterial. This material has great potential for use in head and neck surgery. Specific avenues within laryngology to be investigated include laryngeal and tracheal reconstruction, vocal fold healing, and nerve regeneration. Furthermore, we believe this is the first documented use of the Nuance system to determine aqueous molecular concentrations. Level of Evidence NA Laryngoscope, 124:1392-1397, 2014

Original languageEnglish (US)
Pages (from-to)1392-1397
Number of pages6
JournalLaryngoscope
Volume124
Issue number6
DOIs
StatePublished - Jan 1 2014

Fingerprint

Otolaryngology
Biocompatible Materials
Microspheres
Glass
Laryngoscopes
Quantum Dots
Nerve Regeneration
Regenerative Medicine
Vocal Cords
Pharmaceutical Preparations
Nanoparticles
Microscopy
Neck
Fluorescence
Head
Research

Keywords

  • Nuance FX multispectral imaging system
  • Porous-wall hollow glass microspheres
  • assay
  • biomaterial
  • head and neck surgery
  • laryngology
  • nanocrystals
  • regenerative medicine
  • tracheal transplant

ASJC Scopus subject areas

  • Otorhinolaryngology

Cite this

Cunningham, A., Faircloth, H. A., Jones, M., Johnson, C., Coleman, T., Wicks, G., ... Weinberger, P. M. (2014). A reporter assay for the next generation of biomaterials: Porous-wall hollow glass microspheres. Laryngoscope, 124(6), 1392-1397. https://doi.org/10.1002/lary.24414

A reporter assay for the next generation of biomaterials : Porous-wall hollow glass microspheres. / Cunningham, Aaron; Faircloth, Hunter Allen; Jones, Matthew; Johnson, Christopher; Coleman, Tiffany; Wicks, George; Postma, Gregory N; Weinberger, Paul Maurice.

In: Laryngoscope, Vol. 124, No. 6, 01.01.2014, p. 1392-1397.

Research output: Contribution to journalArticle

Cunningham, A, Faircloth, HA, Jones, M, Johnson, C, Coleman, T, Wicks, G, Postma, GN & Weinberger, PM 2014, 'A reporter assay for the next generation of biomaterials: Porous-wall hollow glass microspheres', Laryngoscope, vol. 124, no. 6, pp. 1392-1397. https://doi.org/10.1002/lary.24414
Cunningham, Aaron ; Faircloth, Hunter Allen ; Jones, Matthew ; Johnson, Christopher ; Coleman, Tiffany ; Wicks, George ; Postma, Gregory N ; Weinberger, Paul Maurice. / A reporter assay for the next generation of biomaterials : Porous-wall hollow glass microspheres. In: Laryngoscope. 2014 ; Vol. 124, No. 6. pp. 1392-1397.
@article{cf4f03ced53a40f8872487d154c66b45,
title = "A reporter assay for the next generation of biomaterials: Porous-wall hollow glass microspheres",
abstract = "Objectives/Hypothesis The primary objective was to design a reporter assay to measure molecular release kinetics from a new porous-wall hollow glass microsphere biomaterial with great potential in regenerative medicine and drug delivery. Second, future avenues for research will be discussed specifically in regard to potential clinical uses in laryngology. Study Design Basic science data report. Methods We developed an assay using fluorescent nanocrystals or quantum dots (Qdot 605) as a reporter. A Nuance FX multispectral imaging system was used to detect fluorescence in aqueous phase. Spectral output of known concentrations of aqueous Qdot 605 was measured by the Nuance system to create a standard curve. Results These data were plotted and fit to a curve. Qdot 605 emission demonstrates excellent correlation with concentration in a log-log relationship [R2-=-0.99649, median error-=-9.9{\%}], indicating that the Qdot 605 assay is reliable and should be explored regarding its ability to evaluate the drug-eluting properties of this material. Conclusions We have derived a method to measure Qdot concentration using fluorescent microscopy, which will facilitate future research on this exciting new biomaterial. This material has great potential for use in head and neck surgery. Specific avenues within laryngology to be investigated include laryngeal and tracheal reconstruction, vocal fold healing, and nerve regeneration. Furthermore, we believe this is the first documented use of the Nuance system to determine aqueous molecular concentrations. Level of Evidence NA Laryngoscope, 124:1392-1397, 2014",
keywords = "Nuance FX multispectral imaging system, Porous-wall hollow glass microspheres, assay, biomaterial, head and neck surgery, laryngology, nanocrystals, regenerative medicine, tracheal transplant",
author = "Aaron Cunningham and Faircloth, {Hunter Allen} and Matthew Jones and Christopher Johnson and Tiffany Coleman and George Wicks and Postma, {Gregory N} and Weinberger, {Paul Maurice}",
year = "2014",
month = "1",
day = "1",
doi = "10.1002/lary.24414",
language = "English (US)",
volume = "124",
pages = "1392--1397",
journal = "Laryngoscope",
issn = "0023-852X",
publisher = "Wiley-Blackwell",
number = "6",

}

TY - JOUR

T1 - A reporter assay for the next generation of biomaterials

T2 - Porous-wall hollow glass microspheres

AU - Cunningham, Aaron

AU - Faircloth, Hunter Allen

AU - Jones, Matthew

AU - Johnson, Christopher

AU - Coleman, Tiffany

AU - Wicks, George

AU - Postma, Gregory N

AU - Weinberger, Paul Maurice

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Objectives/Hypothesis The primary objective was to design a reporter assay to measure molecular release kinetics from a new porous-wall hollow glass microsphere biomaterial with great potential in regenerative medicine and drug delivery. Second, future avenues for research will be discussed specifically in regard to potential clinical uses in laryngology. Study Design Basic science data report. Methods We developed an assay using fluorescent nanocrystals or quantum dots (Qdot 605) as a reporter. A Nuance FX multispectral imaging system was used to detect fluorescence in aqueous phase. Spectral output of known concentrations of aqueous Qdot 605 was measured by the Nuance system to create a standard curve. Results These data were plotted and fit to a curve. Qdot 605 emission demonstrates excellent correlation with concentration in a log-log relationship [R2-=-0.99649, median error-=-9.9%], indicating that the Qdot 605 assay is reliable and should be explored regarding its ability to evaluate the drug-eluting properties of this material. Conclusions We have derived a method to measure Qdot concentration using fluorescent microscopy, which will facilitate future research on this exciting new biomaterial. This material has great potential for use in head and neck surgery. Specific avenues within laryngology to be investigated include laryngeal and tracheal reconstruction, vocal fold healing, and nerve regeneration. Furthermore, we believe this is the first documented use of the Nuance system to determine aqueous molecular concentrations. Level of Evidence NA Laryngoscope, 124:1392-1397, 2014

AB - Objectives/Hypothesis The primary objective was to design a reporter assay to measure molecular release kinetics from a new porous-wall hollow glass microsphere biomaterial with great potential in regenerative medicine and drug delivery. Second, future avenues for research will be discussed specifically in regard to potential clinical uses in laryngology. Study Design Basic science data report. Methods We developed an assay using fluorescent nanocrystals or quantum dots (Qdot 605) as a reporter. A Nuance FX multispectral imaging system was used to detect fluorescence in aqueous phase. Spectral output of known concentrations of aqueous Qdot 605 was measured by the Nuance system to create a standard curve. Results These data were plotted and fit to a curve. Qdot 605 emission demonstrates excellent correlation with concentration in a log-log relationship [R2-=-0.99649, median error-=-9.9%], indicating that the Qdot 605 assay is reliable and should be explored regarding its ability to evaluate the drug-eluting properties of this material. Conclusions We have derived a method to measure Qdot concentration using fluorescent microscopy, which will facilitate future research on this exciting new biomaterial. This material has great potential for use in head and neck surgery. Specific avenues within laryngology to be investigated include laryngeal and tracheal reconstruction, vocal fold healing, and nerve regeneration. Furthermore, we believe this is the first documented use of the Nuance system to determine aqueous molecular concentrations. Level of Evidence NA Laryngoscope, 124:1392-1397, 2014

KW - Nuance FX multispectral imaging system

KW - Porous-wall hollow glass microspheres

KW - assay

KW - biomaterial

KW - head and neck surgery

KW - laryngology

KW - nanocrystals

KW - regenerative medicine

KW - tracheal transplant

UR - http://www.scopus.com/inward/record.url?scp=84901666434&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901666434&partnerID=8YFLogxK

U2 - 10.1002/lary.24414

DO - 10.1002/lary.24414

M3 - Article

VL - 124

SP - 1392

EP - 1397

JO - Laryngoscope

JF - Laryngoscope

SN - 0023-852X

IS - 6

ER -