Calculation of hemoglobin saturation from in vivo human brain tissues using a modified diffusion theory model

M. Johns, Cole A. Giller, H. Liu

Research output: Contribution to journalConference article

3 Citations (Scopus)

Abstract

During deep brain stimulation, a neurosurgical procedure to relieve tremors, a thin electrode is inserted into deep brain regions to provide stimulation. Accurate electrode placement is crucial to provide tremor suppression without damaging adjacent optical and motor regions. A portable, real-time display fiber optic reflectance probe is used to obtain reflected signals from living, human brain tissues. The optical results are compared to pre-operative MRI scans to confirm anatomical structures and verify electrode placement. In addition to reflectance, tissue oxygen saturation may assist brain tissue identification. A modified diffusion model has been developed and tested using Monte Carlo data for small source-detector separations between 500 to 600 nm for hemoglobin oxygen saturation levels of 100% and 0%. In turn, curve fitting between the spectral curves and the model was performed, producing errors of 5.24% and 5.43%, respectively, for cases of 100% and 0% hemoglobin saturation. Additional validation was performed through in vitro studies. Following validation, the model was then used to extract oxygen saturation values from in vivo reflectance spectra. This method permits calculations for hemoglobin saturation and absorption and scattering coefficients from in vivo tissues. Those parameters may be used as clinical markers for neurological localization in the future.

Original languageEnglish (US)
Pages (from-to)194-203
Number of pages10
JournalProceedings of SPIE - The International Society for Optical Engineering
Volume4254
DOIs
StatePublished - Jan 1 2001
Externally publishedYes
EventBiomedical Diagnostic, Guidance, and Surgical-Assist Systems III - San Jose, CA, United States
Duration: Jan 21 2001Jan 22 2001

Fingerprint

diffusion theory
Hemoglobin
hemoglobin
Model Theory
brain
Saturation
Brain
Hemoglobins
Tissue
saturation
Reflectance
Electrode
Oxygen
tremors
Electrodes
Hemoglobin oxygen saturation
reflectance
stimulation
Placement
electrodes

Keywords

  • Absorption
  • Fiber optic applications
  • Reflectance
  • Scattering
  • Spectroscopy

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Computer Science Applications
  • Applied Mathematics
  • Electrical and Electronic Engineering

Cite this

Calculation of hemoglobin saturation from in vivo human brain tissues using a modified diffusion theory model. / Johns, M.; Giller, Cole A.; Liu, H.

In: Proceedings of SPIE - The International Society for Optical Engineering, Vol. 4254, 01.01.2001, p. 194-203.

Research output: Contribution to journalConference article

@article{ac506b6135f744a0bc7881aa53d33db8,
title = "Calculation of hemoglobin saturation from in vivo human brain tissues using a modified diffusion theory model",
abstract = "During deep brain stimulation, a neurosurgical procedure to relieve tremors, a thin electrode is inserted into deep brain regions to provide stimulation. Accurate electrode placement is crucial to provide tremor suppression without damaging adjacent optical and motor regions. A portable, real-time display fiber optic reflectance probe is used to obtain reflected signals from living, human brain tissues. The optical results are compared to pre-operative MRI scans to confirm anatomical structures and verify electrode placement. In addition to reflectance, tissue oxygen saturation may assist brain tissue identification. A modified diffusion model has been developed and tested using Monte Carlo data for small source-detector separations between 500 to 600 nm for hemoglobin oxygen saturation levels of 100{\%} and 0{\%}. In turn, curve fitting between the spectral curves and the model was performed, producing errors of 5.24{\%} and 5.43{\%}, respectively, for cases of 100{\%} and 0{\%} hemoglobin saturation. Additional validation was performed through in vitro studies. Following validation, the model was then used to extract oxygen saturation values from in vivo reflectance spectra. This method permits calculations for hemoglobin saturation and absorption and scattering coefficients from in vivo tissues. Those parameters may be used as clinical markers for neurological localization in the future.",
keywords = "Absorption, Fiber optic applications, Reflectance, Scattering, Spectroscopy",
author = "M. Johns and Giller, {Cole A.} and H. Liu",
year = "2001",
month = "1",
day = "1",
doi = "10.1117/12.427934",
language = "English (US)",
volume = "4254",
pages = "194--203",
journal = "Proceedings of SPIE - The International Society for Optical Engineering",
issn = "0277-786X",
publisher = "SPIE",

}

TY - JOUR

T1 - Calculation of hemoglobin saturation from in vivo human brain tissues using a modified diffusion theory model

AU - Johns, M.

AU - Giller, Cole A.

AU - Liu, H.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - During deep brain stimulation, a neurosurgical procedure to relieve tremors, a thin electrode is inserted into deep brain regions to provide stimulation. Accurate electrode placement is crucial to provide tremor suppression without damaging adjacent optical and motor regions. A portable, real-time display fiber optic reflectance probe is used to obtain reflected signals from living, human brain tissues. The optical results are compared to pre-operative MRI scans to confirm anatomical structures and verify electrode placement. In addition to reflectance, tissue oxygen saturation may assist brain tissue identification. A modified diffusion model has been developed and tested using Monte Carlo data for small source-detector separations between 500 to 600 nm for hemoglobin oxygen saturation levels of 100% and 0%. In turn, curve fitting between the spectral curves and the model was performed, producing errors of 5.24% and 5.43%, respectively, for cases of 100% and 0% hemoglobin saturation. Additional validation was performed through in vitro studies. Following validation, the model was then used to extract oxygen saturation values from in vivo reflectance spectra. This method permits calculations for hemoglobin saturation and absorption and scattering coefficients from in vivo tissues. Those parameters may be used as clinical markers for neurological localization in the future.

AB - During deep brain stimulation, a neurosurgical procedure to relieve tremors, a thin electrode is inserted into deep brain regions to provide stimulation. Accurate electrode placement is crucial to provide tremor suppression without damaging adjacent optical and motor regions. A portable, real-time display fiber optic reflectance probe is used to obtain reflected signals from living, human brain tissues. The optical results are compared to pre-operative MRI scans to confirm anatomical structures and verify electrode placement. In addition to reflectance, tissue oxygen saturation may assist brain tissue identification. A modified diffusion model has been developed and tested using Monte Carlo data for small source-detector separations between 500 to 600 nm for hemoglobin oxygen saturation levels of 100% and 0%. In turn, curve fitting between the spectral curves and the model was performed, producing errors of 5.24% and 5.43%, respectively, for cases of 100% and 0% hemoglobin saturation. Additional validation was performed through in vitro studies. Following validation, the model was then used to extract oxygen saturation values from in vivo reflectance spectra. This method permits calculations for hemoglobin saturation and absorption and scattering coefficients from in vivo tissues. Those parameters may be used as clinical markers for neurological localization in the future.

KW - Absorption

KW - Fiber optic applications

KW - Reflectance

KW - Scattering

KW - Spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=0034864405&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034864405&partnerID=8YFLogxK

U2 - 10.1117/12.427934

DO - 10.1117/12.427934

M3 - Conference article

AN - SCOPUS:0034864405

VL - 4254

SP - 194

EP - 203

JO - Proceedings of SPIE - The International Society for Optical Engineering

JF - Proceedings of SPIE - The International Society for Optical Engineering

SN - 0277-786X

ER -