Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods: A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results: Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion: The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values.

Original languageEnglish (US)
Pages (from-to)3-12
Number of pages10
JournalCaries Research
Volume45
Issue number1
DOIs
StatePublished - Apr 1 2011

Fingerprint

Ion-Selective Electrodes
Fluorides
Dental Research
Food and Beverages
Saliva

Keywords

  • Fluoride
  • Fluoride analysis
  • Fluoride ion-selective electrode
  • Public dental health
  • Validity

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Martínez-Mier, E. A., Cury, J. A., Heilman, J. R., Katz, B. P., Levy, S. M., Li, Y., ... Zohouri, V. (2011). Development of gold standard ion-selective electrode-based methods for fluoride analysis. Caries Research, 45(1), 3-12. https://doi.org/10.1159/000321657

Development of gold standard ion-selective electrode-based methods for fluoride analysis. / Martínez-Mier, E. A.; Cury, J. A.; Heilman, J. R.; Katz, B. P.; Levy, S. M.; Li, Y.; Maguire, A.; Margineda, J.; O'Mullane, D.; Phantumvanit, P.; Soto-Rojas, A. E.; Stookey, G. K.; Villa, A.; Wefel, J. S.; Whelton, H.; Whitford, Gary M.; Zero, D. T.; Zhang, W.; Zohouri, V.

In: Caries Research, Vol. 45, No. 1, 01.04.2011, p. 3-12.

Research output: Contribution to journalArticle

Martínez-Mier, EA, Cury, JA, Heilman, JR, Katz, BP, Levy, SM, Li, Y, Maguire, A, Margineda, J, O'Mullane, D, Phantumvanit, P, Soto-Rojas, AE, Stookey, GK, Villa, A, Wefel, JS, Whelton, H, Whitford, GM, Zero, DT, Zhang, W & Zohouri, V 2011, 'Development of gold standard ion-selective electrode-based methods for fluoride analysis', Caries Research, vol. 45, no. 1, pp. 3-12. https://doi.org/10.1159/000321657
Martínez-Mier EA, Cury JA, Heilman JR, Katz BP, Levy SM, Li Y et al. Development of gold standard ion-selective electrode-based methods for fluoride analysis. Caries Research. 2011 Apr 1;45(1):3-12. https://doi.org/10.1159/000321657
Martínez-Mier, E. A. ; Cury, J. A. ; Heilman, J. R. ; Katz, B. P. ; Levy, S. M. ; Li, Y. ; Maguire, A. ; Margineda, J. ; O'Mullane, D. ; Phantumvanit, P. ; Soto-Rojas, A. E. ; Stookey, G. K. ; Villa, A. ; Wefel, J. S. ; Whelton, H. ; Whitford, Gary M. ; Zero, D. T. ; Zhang, W. ; Zohouri, V. / Development of gold standard ion-selective electrode-based methods for fluoride analysis. In: Caries Research. 2011 ; Vol. 45, No. 1. pp. 3-12.
@article{aca3f63922af4a948a9805de6ab18ae0,
title = "Development of gold standard ion-selective electrode-based methods for fluoride analysis",
abstract = "Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods: A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results: Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion: The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values.",
keywords = "Fluoride, Fluoride analysis, Fluoride ion-selective electrode, Public dental health, Validity",
author = "Mart{\'i}nez-Mier, {E. A.} and Cury, {J. A.} and Heilman, {J. R.} and Katz, {B. P.} and Levy, {S. M.} and Y. Li and A. Maguire and J. Margineda and D. O'Mullane and P. Phantumvanit and Soto-Rojas, {A. E.} and Stookey, {G. K.} and A. Villa and Wefel, {J. S.} and H. Whelton and Whitford, {Gary M.} and Zero, {D. T.} and W. Zhang and V. Zohouri",
year = "2011",
month = "4",
day = "1",
doi = "10.1159/000321657",
language = "English (US)",
volume = "45",
pages = "3--12",
journal = "Caries Research",
issn = "0008-6568",
publisher = "S. Karger AG",
number = "1",

}

TY - JOUR

T1 - Development of gold standard ion-selective electrode-based methods for fluoride analysis

AU - Martínez-Mier, E. A.

AU - Cury, J. A.

AU - Heilman, J. R.

AU - Katz, B. P.

AU - Levy, S. M.

AU - Li, Y.

AU - Maguire, A.

AU - Margineda, J.

AU - O'Mullane, D.

AU - Phantumvanit, P.

AU - Soto-Rojas, A. E.

AU - Stookey, G. K.

AU - Villa, A.

AU - Wefel, J. S.

AU - Whelton, H.

AU - Whitford, Gary M.

AU - Zero, D. T.

AU - Zhang, W.

AU - Zohouri, V.

PY - 2011/4/1

Y1 - 2011/4/1

N2 - Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods: A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results: Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion: The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values.

AB - Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods: A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results: Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion: The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values.

KW - Fluoride

KW - Fluoride analysis

KW - Fluoride ion-selective electrode

KW - Public dental health

KW - Validity

UR - http://www.scopus.com/inward/record.url?scp=78650073559&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78650073559&partnerID=8YFLogxK

U2 - 10.1159/000321657

DO - 10.1159/000321657

M3 - Article

C2 - 21160184

AN - SCOPUS:78650073559

VL - 45

SP - 3

EP - 12

JO - Caries Research

JF - Caries Research

SN - 0008-6568

IS - 1

ER -