Dimensional changes and ultimate tensile strengths of wet decalcified dentin applied with one-bottle adhesives

M. Nakajima, M. Okuda, P. N.R. Pereira, J. Tagami, David Henry Pashley

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

Objectives: The objectives of this study were to test the null hypothesis that no dimensional changes in wet decalcified dentin matrices will occur during the application of one-bottle adhesives, and to evaluate the ultimate tensile strengths (UTS) of resin-infiltrated dentin matrices using the microtensile test. Methods: Dentin disks 0.2mm thick were prepared from mid-coronal dentin of human unerupted third molars. They were completely decalcified in 0.5M EDTA (pH 7.4) for 5 days at 25°C and then placed in the bottom of an aluminum well to permit use of the LVDT portion of a thermal mechanical analyzer. Changes in matrix height in response to the application of Single Bond, One-Step or Prime & Bond NT were measured along with the UTS of resin-infiltrated specimens that were compared using a one-way ANOVA and Fisher's PLSD test. Results: All one-bottle adhesives produced a gradual, progressive shrinkage of the decalcified matrix of 26-33%. The shrinkage produced by Single Bond was significantly greater (p<0.05) than that produced by the other adhesives. The UTS of One-Step was significantly higher (<0.05) than that of Prime & Bond NT (42.0±13.6 vs 29.7±1.9MPa, respectively), with Single Bond producing intermediate UTS (34.3±7.4MPa). Significance: If the durability of resin-dentin bonds depends upon the size of interfibrillar spaces for both diffusion channels and resin uptake, then adhesive formulations should be designed to minimize matrix shrinkage during resin infiltration.

Original languageEnglish (US)
Pages (from-to)603-608
Number of pages6
JournalDental Materials
Volume18
Issue number8
DOIs
StatePublished - Dec 1 2002

Fingerprint

Tensile Strength
Bottles
Dentin
Adhesives
Tensile strength
Resins
Third Molar
Ethylenediaminetetraacetic acid
Analysis of variance (ANOVA)
Aluminum
Infiltration
Edetic Acid
Analysis of Variance
Durability
Hot Temperature
single bond

Keywords

  • Adhesive
  • Decalcified dentin
  • Shrinkage
  • Tensile strength

ASJC Scopus subject areas

  • Materials Science(all)
  • Dentistry(all)
  • Mechanics of Materials

Cite this

Dimensional changes and ultimate tensile strengths of wet decalcified dentin applied with one-bottle adhesives. / Nakajima, M.; Okuda, M.; Pereira, P. N.R.; Tagami, J.; Pashley, David Henry.

In: Dental Materials, Vol. 18, No. 8, 01.12.2002, p. 603-608.

Research output: Contribution to journalArticle

Nakajima, M. ; Okuda, M. ; Pereira, P. N.R. ; Tagami, J. ; Pashley, David Henry. / Dimensional changes and ultimate tensile strengths of wet decalcified dentin applied with one-bottle adhesives. In: Dental Materials. 2002 ; Vol. 18, No. 8. pp. 603-608.
@article{4d5f802ee4b948e6953ed134a5ff37a8,
title = "Dimensional changes and ultimate tensile strengths of wet decalcified dentin applied with one-bottle adhesives",
abstract = "Objectives: The objectives of this study were to test the null hypothesis that no dimensional changes in wet decalcified dentin matrices will occur during the application of one-bottle adhesives, and to evaluate the ultimate tensile strengths (UTS) of resin-infiltrated dentin matrices using the microtensile test. Methods: Dentin disks 0.2mm thick were prepared from mid-coronal dentin of human unerupted third molars. They were completely decalcified in 0.5M EDTA (pH 7.4) for 5 days at 25°C and then placed in the bottom of an aluminum well to permit use of the LVDT portion of a thermal mechanical analyzer. Changes in matrix height in response to the application of Single Bond, One-Step or Prime & Bond NT were measured along with the UTS of resin-infiltrated specimens that were compared using a one-way ANOVA and Fisher's PLSD test. Results: All one-bottle adhesives produced a gradual, progressive shrinkage of the decalcified matrix of 26-33{\%}. The shrinkage produced by Single Bond was significantly greater (p<0.05) than that produced by the other adhesives. The UTS of One-Step was significantly higher (<0.05) than that of Prime & Bond NT (42.0±13.6 vs 29.7±1.9MPa, respectively), with Single Bond producing intermediate UTS (34.3±7.4MPa). Significance: If the durability of resin-dentin bonds depends upon the size of interfibrillar spaces for both diffusion channels and resin uptake, then adhesive formulations should be designed to minimize matrix shrinkage during resin infiltration.",
keywords = "Adhesive, Decalcified dentin, Shrinkage, Tensile strength",
author = "M. Nakajima and M. Okuda and Pereira, {P. N.R.} and J. Tagami and Pashley, {David Henry}",
year = "2002",
month = "12",
day = "1",
doi = "10.1016/S0109-5641(02)00004-0",
language = "English (US)",
volume = "18",
pages = "603--608",
journal = "Dental Materials",
issn = "0109-5641",
publisher = "Elsevier Science",
number = "8",

}

TY - JOUR

T1 - Dimensional changes and ultimate tensile strengths of wet decalcified dentin applied with one-bottle adhesives

AU - Nakajima, M.

AU - Okuda, M.

AU - Pereira, P. N.R.

AU - Tagami, J.

AU - Pashley, David Henry

PY - 2002/12/1

Y1 - 2002/12/1

N2 - Objectives: The objectives of this study were to test the null hypothesis that no dimensional changes in wet decalcified dentin matrices will occur during the application of one-bottle adhesives, and to evaluate the ultimate tensile strengths (UTS) of resin-infiltrated dentin matrices using the microtensile test. Methods: Dentin disks 0.2mm thick were prepared from mid-coronal dentin of human unerupted third molars. They were completely decalcified in 0.5M EDTA (pH 7.4) for 5 days at 25°C and then placed in the bottom of an aluminum well to permit use of the LVDT portion of a thermal mechanical analyzer. Changes in matrix height in response to the application of Single Bond, One-Step or Prime & Bond NT were measured along with the UTS of resin-infiltrated specimens that were compared using a one-way ANOVA and Fisher's PLSD test. Results: All one-bottle adhesives produced a gradual, progressive shrinkage of the decalcified matrix of 26-33%. The shrinkage produced by Single Bond was significantly greater (p<0.05) than that produced by the other adhesives. The UTS of One-Step was significantly higher (<0.05) than that of Prime & Bond NT (42.0±13.6 vs 29.7±1.9MPa, respectively), with Single Bond producing intermediate UTS (34.3±7.4MPa). Significance: If the durability of resin-dentin bonds depends upon the size of interfibrillar spaces for both diffusion channels and resin uptake, then adhesive formulations should be designed to minimize matrix shrinkage during resin infiltration.

AB - Objectives: The objectives of this study were to test the null hypothesis that no dimensional changes in wet decalcified dentin matrices will occur during the application of one-bottle adhesives, and to evaluate the ultimate tensile strengths (UTS) of resin-infiltrated dentin matrices using the microtensile test. Methods: Dentin disks 0.2mm thick were prepared from mid-coronal dentin of human unerupted third molars. They were completely decalcified in 0.5M EDTA (pH 7.4) for 5 days at 25°C and then placed in the bottom of an aluminum well to permit use of the LVDT portion of a thermal mechanical analyzer. Changes in matrix height in response to the application of Single Bond, One-Step or Prime & Bond NT were measured along with the UTS of resin-infiltrated specimens that were compared using a one-way ANOVA and Fisher's PLSD test. Results: All one-bottle adhesives produced a gradual, progressive shrinkage of the decalcified matrix of 26-33%. The shrinkage produced by Single Bond was significantly greater (p<0.05) than that produced by the other adhesives. The UTS of One-Step was significantly higher (<0.05) than that of Prime & Bond NT (42.0±13.6 vs 29.7±1.9MPa, respectively), with Single Bond producing intermediate UTS (34.3±7.4MPa). Significance: If the durability of resin-dentin bonds depends upon the size of interfibrillar spaces for both diffusion channels and resin uptake, then adhesive formulations should be designed to minimize matrix shrinkage during resin infiltration.

KW - Adhesive

KW - Decalcified dentin

KW - Shrinkage

KW - Tensile strength

UR - http://www.scopus.com/inward/record.url?scp=0036886349&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036886349&partnerID=8YFLogxK

U2 - 10.1016/S0109-5641(02)00004-0

DO - 10.1016/S0109-5641(02)00004-0

M3 - Article

C2 - 12385902

AN - SCOPUS:0036886349

VL - 18

SP - 603

EP - 608

JO - Dental Materials

JF - Dental Materials

SN - 0109-5641

IS - 8

ER -