Standard KTP laser (potassium titanyl phosphate) wavelength-specific protective eyewear often impairs visualization of tissue changes during laser treatment. This sometimes necessitates eyewear removal to evaluate tissue effects, which wastes time and poses safety concerns. The objective was to determine if “virtual” or “electronic” chromoendoscopy filters, as found on some endoscopy platforms, could alleviate the restricted visualization inherent to protective eyewear. A KTP laser was applied to porcine laryngeal tissue and recorded via video laryngoscopy with 1 optical (Olympus Narrow Band Imaging) and 8 digital (Pentax Medical I-scan) chromoendoscopy filters. Videos were viewed by 11 otolaryngologists wearing protective eyewear. Using a discrete visual analog scale, they rated each filter on its ability to improve visualization,. No filter impaired visualization; 5 of 9 improved visualization. Based on statistical significance, the number of positive responses, and the lack of negative responses, narrow band imaging and the I-scan tone enhancement filter for leukoplakia performed best. These filters could shorten procedure time and improve safety; therefore, further clinical evaluation is warranted.

Original languageEnglish (US)
Pages (from-to)637-640
Number of pages4
JournalOtolaryngology - Head and Neck Surgery (United States)
Volume158
Issue number4
DOIs
StatePublished - Apr 1 2018

Fingerprint

Narrow Band Imaging
Animal Models
Solid-State Lasers
Leukoplakia
Safety
Laryngoscopy
Visual Analog Scale
Endoscopy
Lasers
Swine
Therapeutics

Keywords

  • KTP laser
  • electronic chromoendoscopy
  • i-scan
  • in-office surgery
  • narrow band imaging
  • protective eyewear
  • virtual chromoendoscopy

ASJC Scopus subject areas

  • Surgery
  • Otorhinolaryngology

Cite this

Effect of Chromoendoscopy Filters on Visualization of KTP Laser–Associated Tissue Changes : A Cadaveric Animal Model. / Johnson, Christopher M.; Pate, Mariah B.; Postma, Gregory N.

In: Otolaryngology - Head and Neck Surgery (United States), Vol. 158, No. 4, 01.04.2018, p. 637-640.

Research output: Contribution to journalArticle

@article{a8bb027452f04138a10e6c20ad051c6b,
title = "Effect of Chromoendoscopy Filters on Visualization of KTP Laser–Associated Tissue Changes: A Cadaveric Animal Model",
abstract = "Standard KTP laser (potassium titanyl phosphate) wavelength-specific protective eyewear often impairs visualization of tissue changes during laser treatment. This sometimes necessitates eyewear removal to evaluate tissue effects, which wastes time and poses safety concerns. The objective was to determine if “virtual” or “electronic” chromoendoscopy filters, as found on some endoscopy platforms, could alleviate the restricted visualization inherent to protective eyewear. A KTP laser was applied to porcine laryngeal tissue and recorded via video laryngoscopy with 1 optical (Olympus Narrow Band Imaging) and 8 digital (Pentax Medical I-scan) chromoendoscopy filters. Videos were viewed by 11 otolaryngologists wearing protective eyewear. Using a discrete visual analog scale, they rated each filter on its ability to improve visualization,. No filter impaired visualization; 5 of 9 improved visualization. Based on statistical significance, the number of positive responses, and the lack of negative responses, narrow band imaging and the I-scan tone enhancement filter for leukoplakia performed best. These filters could shorten procedure time and improve safety; therefore, further clinical evaluation is warranted.",
keywords = "KTP laser, electronic chromoendoscopy, i-scan, in-office surgery, narrow band imaging, protective eyewear, virtual chromoendoscopy",
author = "Johnson, {Christopher M.} and Pate, {Mariah B.} and Postma, {Gregory N}",
year = "2018",
month = "4",
day = "1",
doi = "10.1177/0194599817746933",
language = "English (US)",
volume = "158",
pages = "637--640",
journal = "Otolaryngology - Head and Neck Surgery (United States)",
issn = "0194-5998",
publisher = "Mosby Inc.",
number = "4",

}

TY - JOUR

T1 - Effect of Chromoendoscopy Filters on Visualization of KTP Laser–Associated Tissue Changes

T2 - A Cadaveric Animal Model

AU - Johnson, Christopher M.

AU - Pate, Mariah B.

AU - Postma, Gregory N

PY - 2018/4/1

Y1 - 2018/4/1

N2 - Standard KTP laser (potassium titanyl phosphate) wavelength-specific protective eyewear often impairs visualization of tissue changes during laser treatment. This sometimes necessitates eyewear removal to evaluate tissue effects, which wastes time and poses safety concerns. The objective was to determine if “virtual” or “electronic” chromoendoscopy filters, as found on some endoscopy platforms, could alleviate the restricted visualization inherent to protective eyewear. A KTP laser was applied to porcine laryngeal tissue and recorded via video laryngoscopy with 1 optical (Olympus Narrow Band Imaging) and 8 digital (Pentax Medical I-scan) chromoendoscopy filters. Videos were viewed by 11 otolaryngologists wearing protective eyewear. Using a discrete visual analog scale, they rated each filter on its ability to improve visualization,. No filter impaired visualization; 5 of 9 improved visualization. Based on statistical significance, the number of positive responses, and the lack of negative responses, narrow band imaging and the I-scan tone enhancement filter for leukoplakia performed best. These filters could shorten procedure time and improve safety; therefore, further clinical evaluation is warranted.

AB - Standard KTP laser (potassium titanyl phosphate) wavelength-specific protective eyewear often impairs visualization of tissue changes during laser treatment. This sometimes necessitates eyewear removal to evaluate tissue effects, which wastes time and poses safety concerns. The objective was to determine if “virtual” or “electronic” chromoendoscopy filters, as found on some endoscopy platforms, could alleviate the restricted visualization inherent to protective eyewear. A KTP laser was applied to porcine laryngeal tissue and recorded via video laryngoscopy with 1 optical (Olympus Narrow Band Imaging) and 8 digital (Pentax Medical I-scan) chromoendoscopy filters. Videos were viewed by 11 otolaryngologists wearing protective eyewear. Using a discrete visual analog scale, they rated each filter on its ability to improve visualization,. No filter impaired visualization; 5 of 9 improved visualization. Based on statistical significance, the number of positive responses, and the lack of negative responses, narrow band imaging and the I-scan tone enhancement filter for leukoplakia performed best. These filters could shorten procedure time and improve safety; therefore, further clinical evaluation is warranted.

KW - KTP laser

KW - electronic chromoendoscopy

KW - i-scan

KW - in-office surgery

KW - narrow band imaging

KW - protective eyewear

KW - virtual chromoendoscopy

UR - http://www.scopus.com/inward/record.url?scp=85044997955&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044997955&partnerID=8YFLogxK

U2 - 10.1177/0194599817746933

DO - 10.1177/0194599817746933

M3 - Article

VL - 158

SP - 637

EP - 640

JO - Otolaryngology - Head and Neck Surgery (United States)

JF - Otolaryngology - Head and Neck Surgery (United States)

SN - 0194-5998

IS - 4

ER -