Effect of perfusion and blood content on ultrasonic backscattering of liver tissue

Hiroshi Kimitsuki, Richard E. Parsons, Bernard Sigel, Ernest J. Feleppa, Robert M. Golub, Jeffery Justin, Junji Machi, Mary Rorke, Joan Sokil-Melgar, Issei Kodama, Toshihiko Kurohiji, Teruo Kakegawa, Howard A. Zaren

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

The purpose of this study was to determine the effect of blood flow perfusion and red cell content on ultrasonic scattering by liver tissue. Data acquisition for ultrasonic tissue characterization (UTC) employing analysis of the backscattered echoes from the power spectrum was obtained from the same region of pig liver tissue under four conditions: 1) normal perfusion in situ, 2) ischemia in situ in the living pig, 3) ischemia in situ immediately postmortem, and 4) immediately after excision of the liver. Discriminant function analysis was used to evaluate differences in the two basic parameters from the normalized power spectrum: slope and intercept. Normal perfused liver had significantly higher intercept values and lower slope values than liver under the other three conditions. Excised liver showed the lowest intercept and highest slope values (p < 0.01). These experiments indicate that differences in perfusion produce significant differences in ultrasonic scattering by liver tissue (ischemia caused a 3 dB drop in intercept amplitude). Normal or ischemic in vivo and in vitro liver tissue is associated with different patterns of ultrasonic scattering, and scattering data under these various circumstances are not equivalent.

Original languageEnglish (US)
Pages (from-to)39-43
Number of pages5
JournalUltrasound in Medicine and Biology
Volume19
Issue number1
DOIs
StatePublished - Jan 1 1993
Externally publishedYes

Fingerprint

liver
Ultrasonics
blood
backscattering
Perfusion
ultrasonics
Liver
ischemia
swine
Ischemia
slopes
scattering
power spectra
Swine
Discriminant Analysis
blood flow
data acquisition
echoes

Keywords

  • Backscattering from perfused and nonperfused liver tissue
  • In vivo and in vitro scattering
  • Perfusion of liver tissue
  • Power spectrum analysis
  • Ultrasonic backscattering from liver tissue
  • Ultrasonic tissue characterization

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Biophysics
  • Acoustics and Ultrasonics

Cite this

Kimitsuki, H., Parsons, R. E., Sigel, B., Feleppa, E. J., Golub, R. M., Justin, J., ... Zaren, H. A. (1993). Effect of perfusion and blood content on ultrasonic backscattering of liver tissue. Ultrasound in Medicine and Biology, 19(1), 39-43. https://doi.org/10.1016/0301-5629(93)90016-H

Effect of perfusion and blood content on ultrasonic backscattering of liver tissue. / Kimitsuki, Hiroshi; Parsons, Richard E.; Sigel, Bernard; Feleppa, Ernest J.; Golub, Robert M.; Justin, Jeffery; Machi, Junji; Rorke, Mary; Sokil-Melgar, Joan; Kodama, Issei; Kurohiji, Toshihiko; Kakegawa, Teruo; Zaren, Howard A.

In: Ultrasound in Medicine and Biology, Vol. 19, No. 1, 01.01.1993, p. 39-43.

Research output: Contribution to journalArticle

Kimitsuki, H, Parsons, RE, Sigel, B, Feleppa, EJ, Golub, RM, Justin, J, Machi, J, Rorke, M, Sokil-Melgar, J, Kodama, I, Kurohiji, T, Kakegawa, T & Zaren, HA 1993, 'Effect of perfusion and blood content on ultrasonic backscattering of liver tissue', Ultrasound in Medicine and Biology, vol. 19, no. 1, pp. 39-43. https://doi.org/10.1016/0301-5629(93)90016-H
Kimitsuki, Hiroshi ; Parsons, Richard E. ; Sigel, Bernard ; Feleppa, Ernest J. ; Golub, Robert M. ; Justin, Jeffery ; Machi, Junji ; Rorke, Mary ; Sokil-Melgar, Joan ; Kodama, Issei ; Kurohiji, Toshihiko ; Kakegawa, Teruo ; Zaren, Howard A. / Effect of perfusion and blood content on ultrasonic backscattering of liver tissue. In: Ultrasound in Medicine and Biology. 1993 ; Vol. 19, No. 1. pp. 39-43.
@article{885807c453994ba09751cb1314bca5a4,
title = "Effect of perfusion and blood content on ultrasonic backscattering of liver tissue",
abstract = "The purpose of this study was to determine the effect of blood flow perfusion and red cell content on ultrasonic scattering by liver tissue. Data acquisition for ultrasonic tissue characterization (UTC) employing analysis of the backscattered echoes from the power spectrum was obtained from the same region of pig liver tissue under four conditions: 1) normal perfusion in situ, 2) ischemia in situ in the living pig, 3) ischemia in situ immediately postmortem, and 4) immediately after excision of the liver. Discriminant function analysis was used to evaluate differences in the two basic parameters from the normalized power spectrum: slope and intercept. Normal perfused liver had significantly higher intercept values and lower slope values than liver under the other three conditions. Excised liver showed the lowest intercept and highest slope values (p < 0.01). These experiments indicate that differences in perfusion produce significant differences in ultrasonic scattering by liver tissue (ischemia caused a 3 dB drop in intercept amplitude). Normal or ischemic in vivo and in vitro liver tissue is associated with different patterns of ultrasonic scattering, and scattering data under these various circumstances are not equivalent.",
keywords = "Backscattering from perfused and nonperfused liver tissue, In vivo and in vitro scattering, Perfusion of liver tissue, Power spectrum analysis, Ultrasonic backscattering from liver tissue, Ultrasonic tissue characterization",
author = "Hiroshi Kimitsuki and Parsons, {Richard E.} and Bernard Sigel and Feleppa, {Ernest J.} and Golub, {Robert M.} and Jeffery Justin and Junji Machi and Mary Rorke and Joan Sokil-Melgar and Issei Kodama and Toshihiko Kurohiji and Teruo Kakegawa and Zaren, {Howard A.}",
year = "1993",
month = "1",
day = "1",
doi = "10.1016/0301-5629(93)90016-H",
language = "English (US)",
volume = "19",
pages = "39--43",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier USA",
number = "1",

}

TY - JOUR

T1 - Effect of perfusion and blood content on ultrasonic backscattering of liver tissue

AU - Kimitsuki, Hiroshi

AU - Parsons, Richard E.

AU - Sigel, Bernard

AU - Feleppa, Ernest J.

AU - Golub, Robert M.

AU - Justin, Jeffery

AU - Machi, Junji

AU - Rorke, Mary

AU - Sokil-Melgar, Joan

AU - Kodama, Issei

AU - Kurohiji, Toshihiko

AU - Kakegawa, Teruo

AU - Zaren, Howard A.

PY - 1993/1/1

Y1 - 1993/1/1

N2 - The purpose of this study was to determine the effect of blood flow perfusion and red cell content on ultrasonic scattering by liver tissue. Data acquisition for ultrasonic tissue characterization (UTC) employing analysis of the backscattered echoes from the power spectrum was obtained from the same region of pig liver tissue under four conditions: 1) normal perfusion in situ, 2) ischemia in situ in the living pig, 3) ischemia in situ immediately postmortem, and 4) immediately after excision of the liver. Discriminant function analysis was used to evaluate differences in the two basic parameters from the normalized power spectrum: slope and intercept. Normal perfused liver had significantly higher intercept values and lower slope values than liver under the other three conditions. Excised liver showed the lowest intercept and highest slope values (p < 0.01). These experiments indicate that differences in perfusion produce significant differences in ultrasonic scattering by liver tissue (ischemia caused a 3 dB drop in intercept amplitude). Normal or ischemic in vivo and in vitro liver tissue is associated with different patterns of ultrasonic scattering, and scattering data under these various circumstances are not equivalent.

AB - The purpose of this study was to determine the effect of blood flow perfusion and red cell content on ultrasonic scattering by liver tissue. Data acquisition for ultrasonic tissue characterization (UTC) employing analysis of the backscattered echoes from the power spectrum was obtained from the same region of pig liver tissue under four conditions: 1) normal perfusion in situ, 2) ischemia in situ in the living pig, 3) ischemia in situ immediately postmortem, and 4) immediately after excision of the liver. Discriminant function analysis was used to evaluate differences in the two basic parameters from the normalized power spectrum: slope and intercept. Normal perfused liver had significantly higher intercept values and lower slope values than liver under the other three conditions. Excised liver showed the lowest intercept and highest slope values (p < 0.01). These experiments indicate that differences in perfusion produce significant differences in ultrasonic scattering by liver tissue (ischemia caused a 3 dB drop in intercept amplitude). Normal or ischemic in vivo and in vitro liver tissue is associated with different patterns of ultrasonic scattering, and scattering data under these various circumstances are not equivalent.

KW - Backscattering from perfused and nonperfused liver tissue

KW - In vivo and in vitro scattering

KW - Perfusion of liver tissue

KW - Power spectrum analysis

KW - Ultrasonic backscattering from liver tissue

KW - Ultrasonic tissue characterization

UR - http://www.scopus.com/inward/record.url?scp=0027499755&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027499755&partnerID=8YFLogxK

U2 - 10.1016/0301-5629(93)90016-H

DO - 10.1016/0301-5629(93)90016-H

M3 - Article

VL - 19

SP - 39

EP - 43

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 1

ER -