[Effects of application methods of self-etching adhesives on resin-dentin bonding].

Ling Yu, Xiao yan Wang, Fucong Tian, Xue jun Gao

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

To investigate the effects of application time and rubbing action of self-etching adhesives on resin-dentin bond strength and interface morphology in vitro. Caries-free human third molars were wet ground to expose dentin surface. Three self-etching bonding agents were applied with varying application time and with/without rubbing. The microtensile bond strength and interface morphology were evaluated. When etching time was shortened, normal and prolonged, the bond strength was bonding agent 1 (Adper Prompt): (16.30 +/- 2.59), (23.13 +/- 2.56), (22.28 +/- 2.83) MPa, bonding agent 2 (Xeno III): (15.17 +/- 6.07), (34.50 +/- 3.64), (24.87 +/- 7.01) MPa, bonding agent 3 (Clearfil SE Bond): (29.92 +/- 3.32), (42.21 +/- 6.28), (41.07 +/- 3.93) MPa. When etching was applied with and without rubbing, the bond strength was bonding agent 1 (23.13 +/- 2.56), (12.53 +/- 3.73) MPa, bonding agent 2 (23.98 +/- 3.86), (34.50 +/- 3.64) MPa, bonding agent 3 (48.37 +/- 4.95), (42.21 +/- 6.28) MPa. Shortening application time decreased bond strength of self-etching adhesives, while prolonging application time did not increase bond strength of self-etching adhesives. Not all self-etching adhesives applied with rubbing showed increased bond strength to dentin, which is product-dependent. Manufactures' instructions should be followed to achieve optimum bonding.

Original languageEnglish (US)
Pages (from-to)426-428
Number of pages3
JournalZhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology
Volume43
Issue number7
StatePublished - Jul 2008
Externally publishedYes

Fingerprint

Dentin
Adhesives
Third Molar

ASJC Scopus subject areas

  • Medicine(all)

Cite this

[Effects of application methods of self-etching adhesives on resin-dentin bonding]. / Yu, Ling; Wang, Xiao yan; Tian, Fucong; Gao, Xue jun.

In: Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology, Vol. 43, No. 7, 07.2008, p. 426-428.

Research output: Contribution to journalArticle

@article{0a36aebf2ae842a4afef67defe974473,
title = "[Effects of application methods of self-etching adhesives on resin-dentin bonding].",
abstract = "To investigate the effects of application time and rubbing action of self-etching adhesives on resin-dentin bond strength and interface morphology in vitro. Caries-free human third molars were wet ground to expose dentin surface. Three self-etching bonding agents were applied with varying application time and with/without rubbing. The microtensile bond strength and interface morphology were evaluated. When etching time was shortened, normal and prolonged, the bond strength was bonding agent 1 (Adper Prompt): (16.30 +/- 2.59), (23.13 +/- 2.56), (22.28 +/- 2.83) MPa, bonding agent 2 (Xeno III): (15.17 +/- 6.07), (34.50 +/- 3.64), (24.87 +/- 7.01) MPa, bonding agent 3 (Clearfil SE Bond): (29.92 +/- 3.32), (42.21 +/- 6.28), (41.07 +/- 3.93) MPa. When etching was applied with and without rubbing, the bond strength was bonding agent 1 (23.13 +/- 2.56), (12.53 +/- 3.73) MPa, bonding agent 2 (23.98 +/- 3.86), (34.50 +/- 3.64) MPa, bonding agent 3 (48.37 +/- 4.95), (42.21 +/- 6.28) MPa. Shortening application time decreased bond strength of self-etching adhesives, while prolonging application time did not increase bond strength of self-etching adhesives. Not all self-etching adhesives applied with rubbing showed increased bond strength to dentin, which is product-dependent. Manufactures' instructions should be followed to achieve optimum bonding.",
author = "Ling Yu and Wang, {Xiao yan} and Fucong Tian and Gao, {Xue jun}",
year = "2008",
month = "7",
language = "English (US)",
volume = "43",
pages = "426--428",
journal = "Zhonghua kou qiang ke za zhi [Chinese journal of stomatology]",
issn = "1002-0098",
publisher = "Zhonghua Yixuehui Zazhishe",
number = "7",

}

TY - JOUR

T1 - [Effects of application methods of self-etching adhesives on resin-dentin bonding].

AU - Yu, Ling

AU - Wang, Xiao yan

AU - Tian, Fucong

AU - Gao, Xue jun

PY - 2008/7

Y1 - 2008/7

N2 - To investigate the effects of application time and rubbing action of self-etching adhesives on resin-dentin bond strength and interface morphology in vitro. Caries-free human third molars were wet ground to expose dentin surface. Three self-etching bonding agents were applied with varying application time and with/without rubbing. The microtensile bond strength and interface morphology were evaluated. When etching time was shortened, normal and prolonged, the bond strength was bonding agent 1 (Adper Prompt): (16.30 +/- 2.59), (23.13 +/- 2.56), (22.28 +/- 2.83) MPa, bonding agent 2 (Xeno III): (15.17 +/- 6.07), (34.50 +/- 3.64), (24.87 +/- 7.01) MPa, bonding agent 3 (Clearfil SE Bond): (29.92 +/- 3.32), (42.21 +/- 6.28), (41.07 +/- 3.93) MPa. When etching was applied with and without rubbing, the bond strength was bonding agent 1 (23.13 +/- 2.56), (12.53 +/- 3.73) MPa, bonding agent 2 (23.98 +/- 3.86), (34.50 +/- 3.64) MPa, bonding agent 3 (48.37 +/- 4.95), (42.21 +/- 6.28) MPa. Shortening application time decreased bond strength of self-etching adhesives, while prolonging application time did not increase bond strength of self-etching adhesives. Not all self-etching adhesives applied with rubbing showed increased bond strength to dentin, which is product-dependent. Manufactures' instructions should be followed to achieve optimum bonding.

AB - To investigate the effects of application time and rubbing action of self-etching adhesives on resin-dentin bond strength and interface morphology in vitro. Caries-free human third molars were wet ground to expose dentin surface. Three self-etching bonding agents were applied with varying application time and with/without rubbing. The microtensile bond strength and interface morphology were evaluated. When etching time was shortened, normal and prolonged, the bond strength was bonding agent 1 (Adper Prompt): (16.30 +/- 2.59), (23.13 +/- 2.56), (22.28 +/- 2.83) MPa, bonding agent 2 (Xeno III): (15.17 +/- 6.07), (34.50 +/- 3.64), (24.87 +/- 7.01) MPa, bonding agent 3 (Clearfil SE Bond): (29.92 +/- 3.32), (42.21 +/- 6.28), (41.07 +/- 3.93) MPa. When etching was applied with and without rubbing, the bond strength was bonding agent 1 (23.13 +/- 2.56), (12.53 +/- 3.73) MPa, bonding agent 2 (23.98 +/- 3.86), (34.50 +/- 3.64) MPa, bonding agent 3 (48.37 +/- 4.95), (42.21 +/- 6.28) MPa. Shortening application time decreased bond strength of self-etching adhesives, while prolonging application time did not increase bond strength of self-etching adhesives. Not all self-etching adhesives applied with rubbing showed increased bond strength to dentin, which is product-dependent. Manufactures' instructions should be followed to achieve optimum bonding.

UR - http://www.scopus.com/inward/record.url?scp=79952466456&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79952466456&partnerID=8YFLogxK

M3 - Article

C2 - 19031821

AN - SCOPUS:79952466456

VL - 43

SP - 426

EP - 428

JO - Zhonghua kou qiang ke za zhi [Chinese journal of stomatology]

JF - Zhonghua kou qiang ke za zhi [Chinese journal of stomatology]

SN - 1002-0098

IS - 7