Measurement of lower-limb muscle spasticity

Intrarater reliability of Modified Modified Ashworth Scale

Nastaran Ghotbi, Noureddin Nakhostin Ansari, Soofia Naghdi, Scott Hasson

Research output: Contribution to journalArticle

52 Citations (Scopus)

Abstract

The Modified Modified Ashworth Scale (MMAS) is a clinical instrument for measuring spasticity. Few studies have been performed on the reliability of the MMAS. The aim of the present study was to investigate the intrarater reliability of the MMAS for the assessment of spasticity in the lower limb. We conducted a test-retest study on spasticity in the hip adductors, knee extensors, and ankle plantar flexors. Each patient was measured by a hospital-based clinical physiotherapist. Twenty-three patients with stroke or multiple sclerosis (fourteen women, nine men) and a mean +/- standard deviation age of 37.3 +/- 14.1 years participated. The weighted kappa was moderate for the hip adductors (weighted kappa = 0.45, standard error [SE] = 0.16, p = 0.007), good for the knee extensors (weighted kappa = 0.62, SE = 0.12, p < 0.001), and very good for the ankle plantar flexors (weighted kappa = 0.85, SE = 0.05, p < 0.001). The kappa value for overall agreement was very good (weighted kappa = 0.87, SE = 0.03, p < 0.001). The reliability for the ankle plantar flexors was significantly higher than that for the hip adductors. The intrarater reliability of the MMAS in patients with lower-limb muscle spasticity was very good, and it can be used as a measure of spasticity over time.

Original languageEnglish (US)
Pages (from-to)83-88
Number of pages6
JournalJournal of Rehabilitation Research and Development
Volume48
Issue number1
DOIs
StatePublished - Feb 16 2011

Fingerprint

Muscle Spasticity
Ankle
Hip
Lower Extremity
Knee
Physical Therapists
Multiple Sclerosis
Stroke

Keywords

  • Ankle plantar flexors
  • Hip adductors
  • Intrarater
  • Knee extensors
  • Lower limb
  • MMAS
  • Modified Modified Ashworth Scale
  • Muscle spasticity
  • Rehabilitation
  • Reliability

ASJC Scopus subject areas

  • Rehabilitation

Cite this

Measurement of lower-limb muscle spasticity : Intrarater reliability of Modified Modified Ashworth Scale. / Ghotbi, Nastaran; Ansari, Noureddin Nakhostin; Naghdi, Soofia; Hasson, Scott.

In: Journal of Rehabilitation Research and Development, Vol. 48, No. 1, 16.02.2011, p. 83-88.

Research output: Contribution to journalArticle

Ghotbi, Nastaran ; Ansari, Noureddin Nakhostin ; Naghdi, Soofia ; Hasson, Scott. / Measurement of lower-limb muscle spasticity : Intrarater reliability of Modified Modified Ashworth Scale. In: Journal of Rehabilitation Research and Development. 2011 ; Vol. 48, No. 1. pp. 83-88.
@article{8c54c6b5475f418091ae4dc435a7b1aa,
title = "Measurement of lower-limb muscle spasticity: Intrarater reliability of Modified Modified Ashworth Scale",
abstract = "The Modified Modified Ashworth Scale (MMAS) is a clinical instrument for measuring spasticity. Few studies have been performed on the reliability of the MMAS. The aim of the present study was to investigate the intrarater reliability of the MMAS for the assessment of spasticity in the lower limb. We conducted a test-retest study on spasticity in the hip adductors, knee extensors, and ankle plantar flexors. Each patient was measured by a hospital-based clinical physiotherapist. Twenty-three patients with stroke or multiple sclerosis (fourteen women, nine men) and a mean +/- standard deviation age of 37.3 +/- 14.1 years participated. The weighted kappa was moderate for the hip adductors (weighted kappa = 0.45, standard error [SE] = 0.16, p = 0.007), good for the knee extensors (weighted kappa = 0.62, SE = 0.12, p < 0.001), and very good for the ankle plantar flexors (weighted kappa = 0.85, SE = 0.05, p < 0.001). The kappa value for overall agreement was very good (weighted kappa = 0.87, SE = 0.03, p < 0.001). The reliability for the ankle plantar flexors was significantly higher than that for the hip adductors. The intrarater reliability of the MMAS in patients with lower-limb muscle spasticity was very good, and it can be used as a measure of spasticity over time.",
keywords = "Ankle plantar flexors, Hip adductors, Intrarater, Knee extensors, Lower limb, MMAS, Modified Modified Ashworth Scale, Muscle spasticity, Rehabilitation, Reliability",
author = "Nastaran Ghotbi and Ansari, {Noureddin Nakhostin} and Soofia Naghdi and Scott Hasson",
year = "2011",
month = "2",
day = "16",
doi = "10.1682/JRRD.2010.02.0020",
language = "English (US)",
volume = "48",
pages = "83--88",
journal = "Journal of rehabilitation R&D",
issn = "0748-7711",
publisher = "Department of Veterans Affairs",
number = "1",

}

TY - JOUR

T1 - Measurement of lower-limb muscle spasticity

T2 - Intrarater reliability of Modified Modified Ashworth Scale

AU - Ghotbi, Nastaran

AU - Ansari, Noureddin Nakhostin

AU - Naghdi, Soofia

AU - Hasson, Scott

PY - 2011/2/16

Y1 - 2011/2/16

N2 - The Modified Modified Ashworth Scale (MMAS) is a clinical instrument for measuring spasticity. Few studies have been performed on the reliability of the MMAS. The aim of the present study was to investigate the intrarater reliability of the MMAS for the assessment of spasticity in the lower limb. We conducted a test-retest study on spasticity in the hip adductors, knee extensors, and ankle plantar flexors. Each patient was measured by a hospital-based clinical physiotherapist. Twenty-three patients with stroke or multiple sclerosis (fourteen women, nine men) and a mean +/- standard deviation age of 37.3 +/- 14.1 years participated. The weighted kappa was moderate for the hip adductors (weighted kappa = 0.45, standard error [SE] = 0.16, p = 0.007), good for the knee extensors (weighted kappa = 0.62, SE = 0.12, p < 0.001), and very good for the ankle plantar flexors (weighted kappa = 0.85, SE = 0.05, p < 0.001). The kappa value for overall agreement was very good (weighted kappa = 0.87, SE = 0.03, p < 0.001). The reliability for the ankle plantar flexors was significantly higher than that for the hip adductors. The intrarater reliability of the MMAS in patients with lower-limb muscle spasticity was very good, and it can be used as a measure of spasticity over time.

AB - The Modified Modified Ashworth Scale (MMAS) is a clinical instrument for measuring spasticity. Few studies have been performed on the reliability of the MMAS. The aim of the present study was to investigate the intrarater reliability of the MMAS for the assessment of spasticity in the lower limb. We conducted a test-retest study on spasticity in the hip adductors, knee extensors, and ankle plantar flexors. Each patient was measured by a hospital-based clinical physiotherapist. Twenty-three patients with stroke or multiple sclerosis (fourteen women, nine men) and a mean +/- standard deviation age of 37.3 +/- 14.1 years participated. The weighted kappa was moderate for the hip adductors (weighted kappa = 0.45, standard error [SE] = 0.16, p = 0.007), good for the knee extensors (weighted kappa = 0.62, SE = 0.12, p < 0.001), and very good for the ankle plantar flexors (weighted kappa = 0.85, SE = 0.05, p < 0.001). The kappa value for overall agreement was very good (weighted kappa = 0.87, SE = 0.03, p < 0.001). The reliability for the ankle plantar flexors was significantly higher than that for the hip adductors. The intrarater reliability of the MMAS in patients with lower-limb muscle spasticity was very good, and it can be used as a measure of spasticity over time.

KW - Ankle plantar flexors

KW - Hip adductors

KW - Intrarater

KW - Knee extensors

KW - Lower limb

KW - MMAS

KW - Modified Modified Ashworth Scale

KW - Muscle spasticity

KW - Rehabilitation

KW - Reliability

UR - http://www.scopus.com/inward/record.url?scp=79951474825&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951474825&partnerID=8YFLogxK

U2 - 10.1682/JRRD.2010.02.0020

DO - 10.1682/JRRD.2010.02.0020

M3 - Article

VL - 48

SP - 83

EP - 88

JO - Journal of rehabilitation R&D

JF - Journal of rehabilitation R&D

SN - 0748-7711

IS - 1

ER -