Abstract

Introduction: A missing intrauterine device (IUD) poses challenges in diagnosis and treatment. Extrauterine placement of IUDs may cause difficulty in localization. We report a case where use of fluoroscopy just prior to laparoscopic intervention to remove the missing IUD was beneficial. Case: This case report involves a 35-year-old woman who was diagnosed with a missing thread 2 years after insertion of a levonorgestrel IUD (Mirena). Initial diagnostic workup consisting of abdominal X-ray, an ultrasound and diagnostic laparoscopy failed to localize the IUD. We performed an office pelvic ultrasound which confirmed that an IUD was present but could not specifically localize the IUD in the pelvic or abdominal cavity. Hence, we utilized fluoroscopy just prior to laparoscopy to localize and remove the missing device and allow its removal. Conclusion: Various imaging modalities aid in detecting a missing IUD, but proper selection of fluoroscopy helped to localize extrauterine placement of an IUD device. We suggest that utilization of this imaging method just prior to laparoscopy may be of value in selected cases.

Original languageEnglish (US)
Pages (from-to)285-287
Number of pages3
JournalContraception
Volume86
Issue number3
DOIs
StatePublished - Sep 1 2012

Fingerprint

Intrauterine Devices
Fluoroscopy
Case Management
Laparoscopy
Levonorgestrel
Equipment and Supplies
Abdominal Cavity
Radiography

Keywords

  • Fluoroscopy
  • Intra uterine device
  • Laparoscopy
  • Levonorgestrel IUD
  • Migration of IUD
  • Missing IUD

ASJC Scopus subject areas

  • Reproductive Medicine
  • Obstetrics and Gynecology

Cite this

Missing IUD and utilization of fluoroscopy for management : A case report. / Banerjee, Jashoman; Jeelani, Roohi; Berman, Jay M.; Diamond, Michael Peter.

In: Contraception, Vol. 86, No. 3, 01.09.2012, p. 285-287.

Research output: Contribution to journalArticle

Banerjee, Jashoman ; Jeelani, Roohi ; Berman, Jay M. ; Diamond, Michael Peter. / Missing IUD and utilization of fluoroscopy for management : A case report. In: Contraception. 2012 ; Vol. 86, No. 3. pp. 285-287.
@article{73dfbbfead78486fb5274994dac0754c,
title = "Missing IUD and utilization of fluoroscopy for management: A case report",
abstract = "Introduction: A missing intrauterine device (IUD) poses challenges in diagnosis and treatment. Extrauterine placement of IUDs may cause difficulty in localization. We report a case where use of fluoroscopy just prior to laparoscopic intervention to remove the missing IUD was beneficial. Case: This case report involves a 35-year-old woman who was diagnosed with a missing thread 2 years after insertion of a levonorgestrel IUD (Mirena). Initial diagnostic workup consisting of abdominal X-ray, an ultrasound and diagnostic laparoscopy failed to localize the IUD. We performed an office pelvic ultrasound which confirmed that an IUD was present but could not specifically localize the IUD in the pelvic or abdominal cavity. Hence, we utilized fluoroscopy just prior to laparoscopy to localize and remove the missing device and allow its removal. Conclusion: Various imaging modalities aid in detecting a missing IUD, but proper selection of fluoroscopy helped to localize extrauterine placement of an IUD device. We suggest that utilization of this imaging method just prior to laparoscopy may be of value in selected cases.",
keywords = "Fluoroscopy, Intra uterine device, Laparoscopy, Levonorgestrel IUD, Migration of IUD, Missing IUD",
author = "Jashoman Banerjee and Roohi Jeelani and Berman, {Jay M.} and Diamond, {Michael Peter}",
year = "2012",
month = "9",
day = "1",
doi = "10.1016/j.contraception.2011.12.003",
language = "English (US)",
volume = "86",
pages = "285--287",
journal = "Contraception",
issn = "0010-7824",
publisher = "Elsevier USA",
number = "3",

}

TY - JOUR

T1 - Missing IUD and utilization of fluoroscopy for management

T2 - A case report

AU - Banerjee, Jashoman

AU - Jeelani, Roohi

AU - Berman, Jay M.

AU - Diamond, Michael Peter

PY - 2012/9/1

Y1 - 2012/9/1

N2 - Introduction: A missing intrauterine device (IUD) poses challenges in diagnosis and treatment. Extrauterine placement of IUDs may cause difficulty in localization. We report a case where use of fluoroscopy just prior to laparoscopic intervention to remove the missing IUD was beneficial. Case: This case report involves a 35-year-old woman who was diagnosed with a missing thread 2 years after insertion of a levonorgestrel IUD (Mirena). Initial diagnostic workup consisting of abdominal X-ray, an ultrasound and diagnostic laparoscopy failed to localize the IUD. We performed an office pelvic ultrasound which confirmed that an IUD was present but could not specifically localize the IUD in the pelvic or abdominal cavity. Hence, we utilized fluoroscopy just prior to laparoscopy to localize and remove the missing device and allow its removal. Conclusion: Various imaging modalities aid in detecting a missing IUD, but proper selection of fluoroscopy helped to localize extrauterine placement of an IUD device. We suggest that utilization of this imaging method just prior to laparoscopy may be of value in selected cases.

AB - Introduction: A missing intrauterine device (IUD) poses challenges in diagnosis and treatment. Extrauterine placement of IUDs may cause difficulty in localization. We report a case where use of fluoroscopy just prior to laparoscopic intervention to remove the missing IUD was beneficial. Case: This case report involves a 35-year-old woman who was diagnosed with a missing thread 2 years after insertion of a levonorgestrel IUD (Mirena). Initial diagnostic workup consisting of abdominal X-ray, an ultrasound and diagnostic laparoscopy failed to localize the IUD. We performed an office pelvic ultrasound which confirmed that an IUD was present but could not specifically localize the IUD in the pelvic or abdominal cavity. Hence, we utilized fluoroscopy just prior to laparoscopy to localize and remove the missing device and allow its removal. Conclusion: Various imaging modalities aid in detecting a missing IUD, but proper selection of fluoroscopy helped to localize extrauterine placement of an IUD device. We suggest that utilization of this imaging method just prior to laparoscopy may be of value in selected cases.

KW - Fluoroscopy

KW - Intra uterine device

KW - Laparoscopy

KW - Levonorgestrel IUD

KW - Migration of IUD

KW - Missing IUD

UR - http://www.scopus.com/inward/record.url?scp=84865081878&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84865081878&partnerID=8YFLogxK

U2 - 10.1016/j.contraception.2011.12.003

DO - 10.1016/j.contraception.2011.12.003

M3 - Article

C2 - 22305915

AN - SCOPUS:84865081878

VL - 86

SP - 285

EP - 287

JO - Contraception

JF - Contraception

SN - 0010-7824

IS - 3

ER -