Multi-Centre Comparison of Abbott Matrix® Aero™ to Pharmacia Standard Rast®, Modified Rast and Skin Puncture Tests

Dennis Randall Ownby, R. G. Hamilton

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

ABBOTT MATRIX® Aero™ is an enzyme immunoassay which measures specific IgE antibodies to 14 individually calibräted airborne allergens using a single serum specimen. In this study, ABBOTT MATRIX performance was evaluated in comparison to the results of skin puncture test and the Standard and Modified RAST® procedures. The ABBOTT MATRIX demonstrated overall sensitivity of 89% vs. Standard RAST and Modified RAST, with specificity greater than 92% vs. both methods. ABBOTT MATRIX sensitivity vs. skin test (71%) exceeded that of the Standard and Modified RAST procedures (62% and 67% respectively). Positive results reported by ABBOTT MATRIX but not RAST were corroborated by skin test results for 3 of 5 allergens evaluated. All in vitro Systems demonstrated specificity of approximately 90% vs. skin test. The ABBOTT MATRIX System provided results which compared favoräbly with the results of skin test and RAST, but required less hands-on time to obtain quantitative specific IgE measurements to multiple allergens.

Original languageEnglish (US)
Pages (from-to)631-638
Number of pages8
JournalClinical Chemistry and Laboratory Medicine
Volume32
Issue number8
DOIs
StatePublished - Jan 1 1994
Externally publishedYes

Fingerprint

Skin Tests
Punctures
Skin
Allergens
Immunoglobulin E
Immunoenzyme Techniques
Antibodies
Enzymes
Serum

ASJC Scopus subject areas

  • Clinical Biochemistry
  • Biochemistry, medical

Cite this

@article{864b2e49bcd14c699e58127fd5345170,
title = "Multi-Centre Comparison of Abbott Matrix{\circledR} Aero™ to Pharmacia Standard Rast{\circledR}, Modified Rast and Skin Puncture Tests",
abstract = "ABBOTT MATRIX{\circledR} Aero™ is an enzyme immunoassay which measures specific IgE antibodies to 14 individually calibr{\"a}ted airborne allergens using a single serum specimen. In this study, ABBOTT MATRIX performance was evaluated in comparison to the results of skin puncture test and the Standard and Modified RAST{\circledR} procedures. The ABBOTT MATRIX demonstrated overall sensitivity of 89{\%} vs. Standard RAST and Modified RAST, with specificity greater than 92{\%} vs. both methods. ABBOTT MATRIX sensitivity vs. skin test (71{\%}) exceeded that of the Standard and Modified RAST procedures (62{\%} and 67{\%} respectively). Positive results reported by ABBOTT MATRIX but not RAST were corroborated by skin test results for 3 of 5 allergens evaluated. All in vitro Systems demonstrated specificity of approximately 90{\%} vs. skin test. The ABBOTT MATRIX System provided results which compared favor{\"a}bly with the results of skin test and RAST, but required less hands-on time to obtain quantitative specific IgE measurements to multiple allergens.",
author = "Ownby, {Dennis Randall} and Hamilton, {R. G.}",
year = "1994",
month = "1",
day = "1",
doi = "10.1515/cclm.1994.32.8.631",
language = "English (US)",
volume = "32",
pages = "631--638",
journal = "Clinical Chemistry and Laboratory Medicine",
issn = "1434-6621",
publisher = "Walter de Gruyter GmbH & Co. KG",
number = "8",

}

TY - JOUR

T1 - Multi-Centre Comparison of Abbott Matrix® Aero™ to Pharmacia Standard Rast®, Modified Rast and Skin Puncture Tests

AU - Ownby, Dennis Randall

AU - Hamilton, R. G.

PY - 1994/1/1

Y1 - 1994/1/1

N2 - ABBOTT MATRIX® Aero™ is an enzyme immunoassay which measures specific IgE antibodies to 14 individually calibräted airborne allergens using a single serum specimen. In this study, ABBOTT MATRIX performance was evaluated in comparison to the results of skin puncture test and the Standard and Modified RAST® procedures. The ABBOTT MATRIX demonstrated overall sensitivity of 89% vs. Standard RAST and Modified RAST, with specificity greater than 92% vs. both methods. ABBOTT MATRIX sensitivity vs. skin test (71%) exceeded that of the Standard and Modified RAST procedures (62% and 67% respectively). Positive results reported by ABBOTT MATRIX but not RAST were corroborated by skin test results for 3 of 5 allergens evaluated. All in vitro Systems demonstrated specificity of approximately 90% vs. skin test. The ABBOTT MATRIX System provided results which compared favoräbly with the results of skin test and RAST, but required less hands-on time to obtain quantitative specific IgE measurements to multiple allergens.

AB - ABBOTT MATRIX® Aero™ is an enzyme immunoassay which measures specific IgE antibodies to 14 individually calibräted airborne allergens using a single serum specimen. In this study, ABBOTT MATRIX performance was evaluated in comparison to the results of skin puncture test and the Standard and Modified RAST® procedures. The ABBOTT MATRIX demonstrated overall sensitivity of 89% vs. Standard RAST and Modified RAST, with specificity greater than 92% vs. both methods. ABBOTT MATRIX sensitivity vs. skin test (71%) exceeded that of the Standard and Modified RAST procedures (62% and 67% respectively). Positive results reported by ABBOTT MATRIX but not RAST were corroborated by skin test results for 3 of 5 allergens evaluated. All in vitro Systems demonstrated specificity of approximately 90% vs. skin test. The ABBOTT MATRIX System provided results which compared favoräbly with the results of skin test and RAST, but required less hands-on time to obtain quantitative specific IgE measurements to multiple allergens.

UR - http://www.scopus.com/inward/record.url?scp=84947003340&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84947003340&partnerID=8YFLogxK

U2 - 10.1515/cclm.1994.32.8.631

DO - 10.1515/cclm.1994.32.8.631

M3 - Article

VL - 32

SP - 631

EP - 638

JO - Clinical Chemistry and Laboratory Medicine

JF - Clinical Chemistry and Laboratory Medicine

SN - 1434-6621

IS - 8

ER -