Nanoscopic dynamic mechanical properties of intertubular and peritubular dentin

Heonjune Ryou, Elaine Romberg, David Henry Pashley, Franklin Chi Meng Tay, Dwayne Arola

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency dependent. Specimens of hydrated coronal dentin were evaluated by DMA using single indents over a range of parametric conditions and using scanning probe microscopy. The complex (E *), storage (E ') and loss moduli (E ) of the intertubular and peritubular dentin were evaluated as a function of the dynamic loading frequency and static load in the fully hydrated condition. The mean complex E * (19.6 GPa) and storage E ' (19.2 GPa) moduli of the intertubular dentin were significantly lower than those for peritubular dentin (E *=31.1 GPa, p<0.05; E '=30.3 GPa, p<0.05). There was no significant influence of dynamic loading frequency on these measures. Although there was no significant difference in the loss modulus (E ) between the two materials (p>0.05), both constituents exhibited a significant increase in E with dynamic load frequency and reduction in the quasi-static component of indentation load. The largest difference in dynamic behavior of the two tissues was noted at small quasi-static indentation loads and the highest frequency.

Original languageEnglish (US)
Pages (from-to)3-16
Number of pages14
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume7
DOIs
StatePublished - Mar 1 2012

Fingerprint

Dynamic mechanical analysis
Indentation
Mechanical properties
Scanning probe microscopy
Nanoindentation
Dynamic loads
Frequency response
Tissue

Keywords

  • Dentin
  • Dynamic Mechanical Analysis (DMA)
  • Elastic modulus
  • Nanoindentation

ASJC Scopus subject areas

  • Biomaterials
  • Biomedical Engineering
  • Mechanics of Materials

Cite this

Nanoscopic dynamic mechanical properties of intertubular and peritubular dentin. / Ryou, Heonjune; Romberg, Elaine; Pashley, David Henry; Tay, Franklin Chi Meng; Arola, Dwayne.

In: Journal of the Mechanical Behavior of Biomedical Materials, Vol. 7, 01.03.2012, p. 3-16.

Research output: Contribution to journalArticle

@article{78fcda2598e64f1fae888e88af28bdd8,
title = "Nanoscopic dynamic mechanical properties of intertubular and peritubular dentin",
abstract = "An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency dependent. Specimens of hydrated coronal dentin were evaluated by DMA using single indents over a range of parametric conditions and using scanning probe microscopy. The complex (E *), storage (E ') and loss moduli (E ″) of the intertubular and peritubular dentin were evaluated as a function of the dynamic loading frequency and static load in the fully hydrated condition. The mean complex E * (19.6 GPa) and storage E ' (19.2 GPa) moduli of the intertubular dentin were significantly lower than those for peritubular dentin (E *=31.1 GPa, p<0.05; E '=30.3 GPa, p<0.05). There was no significant influence of dynamic loading frequency on these measures. Although there was no significant difference in the loss modulus (E ″) between the two materials (p>0.05), both constituents exhibited a significant increase in E ″ with dynamic load frequency and reduction in the quasi-static component of indentation load. The largest difference in dynamic behavior of the two tissues was noted at small quasi-static indentation loads and the highest frequency.",
keywords = "Dentin, Dynamic Mechanical Analysis (DMA), Elastic modulus, Nanoindentation",
author = "Heonjune Ryou and Elaine Romberg and Pashley, {David Henry} and Tay, {Franklin Chi Meng} and Dwayne Arola",
year = "2012",
month = "3",
day = "1",
doi = "10.1016/j.jmbbm.2011.08.010",
language = "English (US)",
volume = "7",
pages = "3--16",
journal = "Journal of the Mechanical Behavior of Biomedical Materials",
issn = "1751-6161",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Nanoscopic dynamic mechanical properties of intertubular and peritubular dentin

AU - Ryou, Heonjune

AU - Romberg, Elaine

AU - Pashley, David Henry

AU - Tay, Franklin Chi Meng

AU - Arola, Dwayne

PY - 2012/3/1

Y1 - 2012/3/1

N2 - An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency dependent. Specimens of hydrated coronal dentin were evaluated by DMA using single indents over a range of parametric conditions and using scanning probe microscopy. The complex (E *), storage (E ') and loss moduli (E ″) of the intertubular and peritubular dentin were evaluated as a function of the dynamic loading frequency and static load in the fully hydrated condition. The mean complex E * (19.6 GPa) and storage E ' (19.2 GPa) moduli of the intertubular dentin were significantly lower than those for peritubular dentin (E *=31.1 GPa, p<0.05; E '=30.3 GPa, p<0.05). There was no significant influence of dynamic loading frequency on these measures. Although there was no significant difference in the loss modulus (E ″) between the two materials (p>0.05), both constituents exhibited a significant increase in E ″ with dynamic load frequency and reduction in the quasi-static component of indentation load. The largest difference in dynamic behavior of the two tissues was noted at small quasi-static indentation loads and the highest frequency.

AB - An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency dependent. Specimens of hydrated coronal dentin were evaluated by DMA using single indents over a range of parametric conditions and using scanning probe microscopy. The complex (E *), storage (E ') and loss moduli (E ″) of the intertubular and peritubular dentin were evaluated as a function of the dynamic loading frequency and static load in the fully hydrated condition. The mean complex E * (19.6 GPa) and storage E ' (19.2 GPa) moduli of the intertubular dentin were significantly lower than those for peritubular dentin (E *=31.1 GPa, p<0.05; E '=30.3 GPa, p<0.05). There was no significant influence of dynamic loading frequency on these measures. Although there was no significant difference in the loss modulus (E ″) between the two materials (p>0.05), both constituents exhibited a significant increase in E ″ with dynamic load frequency and reduction in the quasi-static component of indentation load. The largest difference in dynamic behavior of the two tissues was noted at small quasi-static indentation loads and the highest frequency.

KW - Dentin

KW - Dynamic Mechanical Analysis (DMA)

KW - Elastic modulus

KW - Nanoindentation

UR - http://www.scopus.com/inward/record.url?scp=84857122512&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84857122512&partnerID=8YFLogxK

U2 - 10.1016/j.jmbbm.2011.08.010

DO - 10.1016/j.jmbbm.2011.08.010

M3 - Article

VL - 7

SP - 3

EP - 16

JO - Journal of the Mechanical Behavior of Biomedical Materials

JF - Journal of the Mechanical Behavior of Biomedical Materials

SN - 1751-6161

ER -