Abstract

We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAGE® dosimeter (9.5cm diameter, 9.2cm height) with a 0.35cm channel drilled for source placement. The dosimeter was immersed in water and irradiated to 5.3Gy at 1cm. Pre- and post-irradiation optical CT scans were acquired with the Duke Large field of view Optical CT Scanner (DLOS) and dose was reconstructed with 0.5mm isotropic voxel size. The measured radial dose factor matched the published fit to within 3% for radii between 0.5-3.0cm, and the anisotropy function matched to within 4% except for θ near 0° and 180° and radii >3cm. Further improvements in measurement accuracy may be achieved by optimizing dose, using the high dynamic range scanning capability of DLOS, and irradiating multiple dosimeters. Initial simulations indicate an 8 fold increase in dose is possible while still allowing sufficient light transmission during optical CT. A more comprehensive measurement may be achieved by increasing dosimeter size and flipping the source orientation between irradiations.

Original languageEnglish (US)
Article number012100
JournalJournal of Physics: Conference Series
Volume444
Issue number1
DOIs
StatePublished - Jan 1 2013
Event7th International Conference on 3D Radiation Dosimetry, IC3DDose 2012 - Sydney, NSW, Australia
Duration: Dec 4 2012Dec 8 2012

Fingerprint

dosimeters
seeds
tomography
dosage
anisotropy
irradiation
radii
light transmission
scanners
field of view
dynamic range
scanning
water
simulation

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography. / Adamson, J.; Yang, Y.; Rankine, L.; Newton, J.; Adamovics, J.; Craciunescu, O.; Oldham, M.

In: Journal of Physics: Conference Series, Vol. 444, No. 1, 012100, 01.01.2013.

Research output: Contribution to journalConference article

Adamson, J. ; Yang, Y. ; Rankine, L. ; Newton, J. ; Adamovics, J. ; Craciunescu, O. ; Oldham, M. / Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography. In: Journal of Physics: Conference Series. 2013 ; Vol. 444, No. 1.
@article{32cbdea232f847aebb9ff6cfa690130b,
title = "Towards comprehensive characterization of Cs-137 Seeds using PRESAGE{\circledR} dosimetry with optical tomography",
abstract = "We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAGE{\circledR} dosimeter (9.5cm diameter, 9.2cm height) with a 0.35cm channel drilled for source placement. The dosimeter was immersed in water and irradiated to 5.3Gy at 1cm. Pre- and post-irradiation optical CT scans were acquired with the Duke Large field of view Optical CT Scanner (DLOS) and dose was reconstructed with 0.5mm isotropic voxel size. The measured radial dose factor matched the published fit to within 3{\%} for radii between 0.5-3.0cm, and the anisotropy function matched to within 4{\%} except for θ near 0° and 180° and radii >3cm. Further improvements in measurement accuracy may be achieved by optimizing dose, using the high dynamic range scanning capability of DLOS, and irradiating multiple dosimeters. Initial simulations indicate an 8 fold increase in dose is possible while still allowing sufficient light transmission during optical CT. A more comprehensive measurement may be achieved by increasing dosimeter size and flipping the source orientation between irradiations.",
author = "J. Adamson and Y. Yang and L. Rankine and J. Newton and J. Adamovics and O. Craciunescu and M. Oldham",
year = "2013",
month = "1",
day = "1",
doi = "10.1088/1742-6596/444/1/012100",
language = "English (US)",
volume = "444",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography

AU - Adamson, J.

AU - Yang, Y.

AU - Rankine, L.

AU - Newton, J.

AU - Adamovics, J.

AU - Craciunescu, O.

AU - Oldham, M.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAGE® dosimeter (9.5cm diameter, 9.2cm height) with a 0.35cm channel drilled for source placement. The dosimeter was immersed in water and irradiated to 5.3Gy at 1cm. Pre- and post-irradiation optical CT scans were acquired with the Duke Large field of view Optical CT Scanner (DLOS) and dose was reconstructed with 0.5mm isotropic voxel size. The measured radial dose factor matched the published fit to within 3% for radii between 0.5-3.0cm, and the anisotropy function matched to within 4% except for θ near 0° and 180° and radii >3cm. Further improvements in measurement accuracy may be achieved by optimizing dose, using the high dynamic range scanning capability of DLOS, and irradiating multiple dosimeters. Initial simulations indicate an 8 fold increase in dose is possible while still allowing sufficient light transmission during optical CT. A more comprehensive measurement may be achieved by increasing dosimeter size and flipping the source orientation between irradiations.

AB - We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAGE® dosimeter (9.5cm diameter, 9.2cm height) with a 0.35cm channel drilled for source placement. The dosimeter was immersed in water and irradiated to 5.3Gy at 1cm. Pre- and post-irradiation optical CT scans were acquired with the Duke Large field of view Optical CT Scanner (DLOS) and dose was reconstructed with 0.5mm isotropic voxel size. The measured radial dose factor matched the published fit to within 3% for radii between 0.5-3.0cm, and the anisotropy function matched to within 4% except for θ near 0° and 180° and radii >3cm. Further improvements in measurement accuracy may be achieved by optimizing dose, using the high dynamic range scanning capability of DLOS, and irradiating multiple dosimeters. Initial simulations indicate an 8 fold increase in dose is possible while still allowing sufficient light transmission during optical CT. A more comprehensive measurement may be achieved by increasing dosimeter size and flipping the source orientation between irradiations.

UR - http://www.scopus.com/inward/record.url?scp=84883418261&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84883418261&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/444/1/012100

DO - 10.1088/1742-6596/444/1/012100

M3 - Conference article

AN - SCOPUS:84883418261

VL - 444

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012100

ER -