Uncertainties in electron-absorbed fractions and lung doses from inhaled beta-emitters

Eduardo B. Farfán, Wesley E. Bolch, Thomas E. Huston, Didier A. Rajon, Chulhaeng Huh, W. Emmett Bolch

Research output: Contribution to journalReview article

5 Citations (Scopus)

Abstract

The computer code LUDUC (Lung Dose Uncertainty Code), developed at the University of Florida, was originally used to investigate the range of potential doses from the inhalation of either plutonium or uranium oxides. The code employs the ICRP Publication 66 Human Respiratory Tract model; however, rather than using simple point estimates for each of the model parameters associated with particle deposition, clearance, and lung-tissue dosimetry, probability density functions are ascribed to these parameters based upon detailed literature review. These distributions are subsequently sampled within LUDUC using Latin hypercube sampling techniques to generate multiple (e.g., ∼1,000) sets of input vectors (i.e., trials), each yielding a unique estimate of lung dose. In the present study, the dosimetry component of the ICRP-66 model within LUDUC has been extended to explicitly consider variations in the beta particle absorbed fraction due to corresponding uncertainties and biological variabilities in both source and target tissue depths and thicknesses within the bronchi and bronchioles of the thoracic airways. Example dose distributions are given for the inhalation of absorption Type S compounds of 90Sr (Tmax = 546 keV) and 90Y (Tmax = 2,284 keV) as a function of particle size. Over the particle size range of 0.001 to 1 μm, estimates of total lung dose vary by a factor of 10 for 90Sr particles and by a factor of 4 to 10 for 90Y particles. As the particle size increases to 10 μm, dose uncertainties reach a factor of 100 for both radionuclides. In comparisons to identical exposures scenarios run by the LUDEP 2.0 code, Reference Man doses for inhaled beta-emitters were shown to provide slightly conservative estimates of lung dose compared to those in this study where uncertainties in lung airway histology are considered.

Original languageEnglish (US)
Pages (from-to)37-47
Number of pages11
JournalHealth Physics
Volume88
Issue number1
DOIs
StatePublished - Jan 1 2005
Externally publishedYes

Fingerprint

Uncertainty
Electrons
Lung
Particle Size
Inhalation
Beta Particles
Plutonium
Bronchioles
Bronchi
Radioisotopes
Respiratory System
Publications
Histology
Thorax

Keywords

  • Aerosols
  • Beta particles
  • Internal dose
  • Respiratory system

ASJC Scopus subject areas

  • Epidemiology
  • Radiology Nuclear Medicine and imaging
  • Health, Toxicology and Mutagenesis

Cite this

Uncertainties in electron-absorbed fractions and lung doses from inhaled beta-emitters. / Farfán, Eduardo B.; Bolch, Wesley E.; Huston, Thomas E.; Rajon, Didier A.; Huh, Chulhaeng; Bolch, W. Emmett.

In: Health Physics, Vol. 88, No. 1, 01.01.2005, p. 37-47.

Research output: Contribution to journalReview article

Farfán, Eduardo B. ; Bolch, Wesley E. ; Huston, Thomas E. ; Rajon, Didier A. ; Huh, Chulhaeng ; Bolch, W. Emmett. / Uncertainties in electron-absorbed fractions and lung doses from inhaled beta-emitters. In: Health Physics. 2005 ; Vol. 88, No. 1. pp. 37-47.
@article{d3b488cd6b334eb485d1bd92869cffa0,
title = "Uncertainties in electron-absorbed fractions and lung doses from inhaled beta-emitters",
abstract = "The computer code LUDUC (Lung Dose Uncertainty Code), developed at the University of Florida, was originally used to investigate the range of potential doses from the inhalation of either plutonium or uranium oxides. The code employs the ICRP Publication 66 Human Respiratory Tract model; however, rather than using simple point estimates for each of the model parameters associated with particle deposition, clearance, and lung-tissue dosimetry, probability density functions are ascribed to these parameters based upon detailed literature review. These distributions are subsequently sampled within LUDUC using Latin hypercube sampling techniques to generate multiple (e.g., ∼1,000) sets of input vectors (i.e., trials), each yielding a unique estimate of lung dose. In the present study, the dosimetry component of the ICRP-66 model within LUDUC has been extended to explicitly consider variations in the beta particle absorbed fraction due to corresponding uncertainties and biological variabilities in both source and target tissue depths and thicknesses within the bronchi and bronchioles of the thoracic airways. Example dose distributions are given for the inhalation of absorption Type S compounds of 90Sr (Tmax = 546 keV) and 90Y (Tmax = 2,284 keV) as a function of particle size. Over the particle size range of 0.001 to 1 μm, estimates of total lung dose vary by a factor of 10 for 90Sr particles and by a factor of 4 to 10 for 90Y particles. As the particle size increases to 10 μm, dose uncertainties reach a factor of 100 for both radionuclides. In comparisons to identical exposures scenarios run by the LUDEP 2.0 code, Reference Man doses for inhaled beta-emitters were shown to provide slightly conservative estimates of lung dose compared to those in this study where uncertainties in lung airway histology are considered.",
keywords = "Aerosols, Beta particles, Internal dose, Respiratory system",
author = "Farf{\'a}n, {Eduardo B.} and Bolch, {Wesley E.} and Huston, {Thomas E.} and Rajon, {Didier A.} and Chulhaeng Huh and Bolch, {W. Emmett}",
year = "2005",
month = "1",
day = "1",
doi = "10.1097/01.HP.0000142496.73713.e7",
language = "English (US)",
volume = "88",
pages = "37--47",
journal = "Health Physics",
issn = "0017-9078",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Uncertainties in electron-absorbed fractions and lung doses from inhaled beta-emitters

AU - Farfán, Eduardo B.

AU - Bolch, Wesley E.

AU - Huston, Thomas E.

AU - Rajon, Didier A.

AU - Huh, Chulhaeng

AU - Bolch, W. Emmett

PY - 2005/1/1

Y1 - 2005/1/1

N2 - The computer code LUDUC (Lung Dose Uncertainty Code), developed at the University of Florida, was originally used to investigate the range of potential doses from the inhalation of either plutonium or uranium oxides. The code employs the ICRP Publication 66 Human Respiratory Tract model; however, rather than using simple point estimates for each of the model parameters associated with particle deposition, clearance, and lung-tissue dosimetry, probability density functions are ascribed to these parameters based upon detailed literature review. These distributions are subsequently sampled within LUDUC using Latin hypercube sampling techniques to generate multiple (e.g., ∼1,000) sets of input vectors (i.e., trials), each yielding a unique estimate of lung dose. In the present study, the dosimetry component of the ICRP-66 model within LUDUC has been extended to explicitly consider variations in the beta particle absorbed fraction due to corresponding uncertainties and biological variabilities in both source and target tissue depths and thicknesses within the bronchi and bronchioles of the thoracic airways. Example dose distributions are given for the inhalation of absorption Type S compounds of 90Sr (Tmax = 546 keV) and 90Y (Tmax = 2,284 keV) as a function of particle size. Over the particle size range of 0.001 to 1 μm, estimates of total lung dose vary by a factor of 10 for 90Sr particles and by a factor of 4 to 10 for 90Y particles. As the particle size increases to 10 μm, dose uncertainties reach a factor of 100 for both radionuclides. In comparisons to identical exposures scenarios run by the LUDEP 2.0 code, Reference Man doses for inhaled beta-emitters were shown to provide slightly conservative estimates of lung dose compared to those in this study where uncertainties in lung airway histology are considered.

AB - The computer code LUDUC (Lung Dose Uncertainty Code), developed at the University of Florida, was originally used to investigate the range of potential doses from the inhalation of either plutonium or uranium oxides. The code employs the ICRP Publication 66 Human Respiratory Tract model; however, rather than using simple point estimates for each of the model parameters associated with particle deposition, clearance, and lung-tissue dosimetry, probability density functions are ascribed to these parameters based upon detailed literature review. These distributions are subsequently sampled within LUDUC using Latin hypercube sampling techniques to generate multiple (e.g., ∼1,000) sets of input vectors (i.e., trials), each yielding a unique estimate of lung dose. In the present study, the dosimetry component of the ICRP-66 model within LUDUC has been extended to explicitly consider variations in the beta particle absorbed fraction due to corresponding uncertainties and biological variabilities in both source and target tissue depths and thicknesses within the bronchi and bronchioles of the thoracic airways. Example dose distributions are given for the inhalation of absorption Type S compounds of 90Sr (Tmax = 546 keV) and 90Y (Tmax = 2,284 keV) as a function of particle size. Over the particle size range of 0.001 to 1 μm, estimates of total lung dose vary by a factor of 10 for 90Sr particles and by a factor of 4 to 10 for 90Y particles. As the particle size increases to 10 μm, dose uncertainties reach a factor of 100 for both radionuclides. In comparisons to identical exposures scenarios run by the LUDEP 2.0 code, Reference Man doses for inhaled beta-emitters were shown to provide slightly conservative estimates of lung dose compared to those in this study where uncertainties in lung airway histology are considered.

KW - Aerosols

KW - Beta particles

KW - Internal dose

KW - Respiratory system

UR - http://www.scopus.com/inward/record.url?scp=12944314767&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12944314767&partnerID=8YFLogxK

U2 - 10.1097/01.HP.0000142496.73713.e7

DO - 10.1097/01.HP.0000142496.73713.e7

M3 - Review article

C2 - 15596988

AN - SCOPUS:12944314767

VL - 88

SP - 37

EP - 47

JO - Health Physics

JF - Health Physics

SN - 0017-9078

IS - 1

ER -